Rapid determination of methotrexate in plasma by high-performance liquid chromatography with on-line solid-phase extraction and automated precolumn derivatization

被引:0
|
作者
Emara, S [1 ]
Askal, H
Masujima, T
机构
[1] Suez Canal Univ, Fac Pharm, Dept Analyt Chem, Ismailia, Egypt
[2] Assiut Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Assiut, Egypt
[3] Hiroshima Univ, Sch Med, Inst Pharmaceut Sci, Minami Ku, Hiroshima 734, Japan
关键词
D O I
10.1002/(SICI)1099-0801(199811/12)12:6<338::AID-BMC759>3.0.CO;2-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatographic system, combining solid-phase extraction and automated precolumn derivatization is described for the routine determination of methotrexate in human plasma, The sample extraction and elution onto the analytical column were performed automatically and concomitantly using the column-switching technique and a protein-coated precolumn, Cerium (IV) trihydroxyhydroperoxide (CTH) was introduced as a packed oxidant before the analytical column for the conversion of methotrexate into highly fluorescent products, The oxidative-cleavage of methotrexate occurs during the flow of 0.04 M phosphate buffer (pH 3.5) containing plasma sample through CTH column with a flow rate of 0.5 mL/min at 40 degrees C, The fluorescent products were transferred to the protein-coated precolumn, which was then flushed with the same buffer for clean-up and enrichment from plasma sample, The trapped substances were desorbed from the precolumn and eluted onto the ODS/TM analytical column by isocratical elution with a mobile phase containing 0.05 M phosphate buffer, pH 6.6 and acetonitrile (90-10, v/v) for subsequent separation. The fluorescent products were detected fluorimetrically at excitation and emission wavelengths of 367 and 463 nm, respectively. The complete analysis was achieved within 15 min per sample. The calibration graph was linear in the range of 50-500 ng/mL of methotrexate and there was no interference from endogenous components. (C) 1998 John Wiley & Sons, Ltd.
引用
收藏
页码:338 / 342
页数:5
相关论文
共 50 条
  • [1] Rapid determination of methotrexate in plasma by high-performance liquid chromatography with on-line solid-phase extraction and automated precolumn derivatization
    Emara, Samy
    Askal, Hassan
    Masujima, Tsutomu
    Biomedical Chromatography, 12 (06): : 338 - 342
  • [2] On-line solid-phase extraction and high performance liquid chromatography for the determination of bromide
    Jain, A
    Mishra, S
    Sahasrabuddhey, B
    Verma, KK
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1997, 36 (10): : 908 - 912
  • [3] Quantitation of nifedipine in human plasma by on-line solid-phase extraction and high-performance liquid chromatography
    Yritia, M
    Parra, P
    Iglesias, E
    Barbanoj, JM
    JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) : 115 - 119
  • [4] On-line coupling of solid-phase extraction to high-performance liquid chromatography for determination of estrogens in environment
    Wang, Shuo
    Huang, Wei
    Fang, Guozhen
    He, Jinxing
    Zhang, Yan
    ANALYTICA CHIMICA ACTA, 2008, 606 (02) : 194 - 201
  • [5] Determination of Morphine in Pharmaceutical Products by On-Line Solid-Phase Extraction and High-Performance Liquid Chromatography
    Yang, Yan-Ling
    Ye, Xiao-Xue
    Li, Yu-Sang
    Tan, Zhi-Fang
    Jiang, Ji-Zhou
    ANALYTICAL LETTERS, 2016, 49 (09) : 1303 - 1309
  • [6] Determination of tetracyclines residues in honey by on-line solid-phase extraction high-performance liquid chromatography
    Li, Jiantao
    Chen, Ligang
    Wang, Xiao
    Jin, Haiyan
    Ding, Lan
    Zhang, Kun
    Zhang, Hanqi
    TALANTA, 2008, 75 (05) : 1245 - 1252
  • [7] RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF NIFEDIPINE IN PLASMA WITH ONLINE PRECOLUMN SOLID-PHASE EXTRACTION
    NITSCHE, V
    SCHUTZ, H
    EICHINGER, A
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 420 (01): : 207 - 211
  • [8] Ion-pairing high-performance liquid chromatography determination of amitrole in apple after solid-phase extraction and precolumn derivatization
    Yan Sun
    Laixin Luo
    Fang Wang
    Jianqiang Li
    Yongsong Cao
    Analytical and Bioanalytical Chemistry, 2009, 395 : 465 - 471
  • [9] Ion-pairing high-performance liquid chromatography determination of amitrole in apple after solid-phase extraction and precolumn derivatization
    Sun, Yan
    Luo, Laixin
    Wang, Fang
    Li, Jianqiang
    Cao, Yongsong
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (02) : 465 - 471
  • [10] Automated solid-phase extraction method for the determination of atovaquone in plasma and whole blood by rapid high-performance liquid chromatography
    Lindegårdh, N
    Bergqvist, Y
    JOURNAL OF CHROMATOGRAPHY B, 2000, 744 (01): : 9 - 17