Priori mask guided image reconstruction (p-MGIR) for ultra-low dose cone-beam computed tomography

被引:6
|
作者
Park, Justin C. [1 ]
Zhang, Hao [2 ]
Chen, Yunmei [2 ]
Fan, Qiyong [3 ]
Kahler, Darren L. [1 ]
Liu, Chihray [1 ]
Lu, Bo [1 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Math, Gainesville, FL 32611 USA
[3] Univ Nebraska Med Ctr, Dept Radiat Oncol, Omaha, NE 68105 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 21期
关键词
p-MGIR; 3DCBCT; iterative image reconstruction; compressed sensing; on-line IGRT; COMPRESSED SENSING ABOCS; CT RECONSTRUCTION; CANCER-RISKS; GPU; PROJECTION; ALGORITHM; NOISE;
D O I
10.1088/0031-9155/60/21/8505
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, the compressed sensing (CS) based iterative reconstruction method has received attention because of its ability to reconstruct cone beam computed tomography (CBCT) images with good quality using sparsely sampled or noisy projections, thus enabling dose reduction. However, some challenges remain. In particular, there is always a tradeoff between image resolution and noise/streak artifact reduction based on the amount of regularization weighting that is applied uniformly across the CBCT volume. The purpose of this study is to develop a novel low-dose CBCT reconstruction algorithm framework called priori mask guided image reconstruction (p-MGIR) that allows reconstruction of high-quality low-dose CBCT images while preserving the image resolution. In p-MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions: (1) where anatomical structures are complex, and (2) where intensities are relatively uniform. The priori mask, which is the key concept of the p-MGIR algorithm, was defined as the matrix that distinguishes between the two separate CBCT regions where the resolution needs to be preserved and where streak or noise needs to be suppressed. We then alternately updated each part of image by solving two sub-minimization problems iteratively, where one minimization was focused on preserving the edge information of the first part while the other concentrated on the removal of noise/artifacts from the latter part. To evaluate the performance of the p-MGIR algorithm, a numerical head-and-neck phantom, a Catphan 600 physical phantom, and a clinical head-and-neck cancer case were used for analysis. The results were compared with the standard Feldkamp-Davis-Kress as well as conventional CS-based algorithms. Examination of the p-MGIR algorithm showed that high-quality low-dose CBCT images can be reconstructed without compromising the image resolution. For both phantom and the patient cases, the p-MGIR is able to achieve a clinically-reasonable image with 60 projections. Therefore, a clinically-viable, high-resolution head-and-neck CBCT image can be obtained while cutting the dose by 83%. Moreover, the image quality obtained using p-MGIR is better than the quality obtained using other algorithms. In this work, we propose a novel low-dose CBCT reconstruction algorithm called p-MGIR. It can be potentially used as a CBCT reconstruction algorithm with low dose scan requests
引用
收藏
页码:8505 / 8524
页数:20
相关论文
共 50 条
  • [31] EVALUATION OF DOSE HOMOGENEITY IN CONE-BEAM BREAST COMPUTED TOMOGRAPHY
    Mettivier, Giovanni
    Costa, Matilde
    Lanconelli, Nico
    Ianiro, Anna
    Pugliese, Mariagabriella
    Quarto, Maria
    Russo, Paolo
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (04) : 473 - 481
  • [32] Flat-panel cone-beam computed tomography for image-guided radiation therapy
    Jaffray, DA
    Siewerdsen, JH
    Wong, JW
    Martinez, AA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1337 - 1349
  • [33] Cone-beam computed tomography (CBCT) for adaptive image guided head and neck radiation therapy
    Hvid, Christian A.
    Elstrom, Ulrik V.
    Jensen, Kenneth
    Grau, Cai
    ACTA ONCOLOGICA, 2018, 57 (04) : 552 - 556
  • [34] PSDP: Pseudo-supervised dual-processing for low-dose cone-beam computed tomography reconstruction
    Chao, Lianying
    Shan, Wenqi
    Wang, Yanli
    Xu, Wenting
    Zhang, Haobo
    Wang, Zhiwei
    Li, Qiang
    EXPERT SYSTEMS WITH APPLICATIONS, 2023, 224
  • [35] Accelerated iterative image reconstruction for cone-beam computed tomography through Big Data frameworks
    Serrano, Estefania
    Garcia-Blas, Javier
    Carretero, Jesus
    Desco, Manuel
    Abella, Monica
    FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2020, 106 : 534 - 544
  • [36] Iterative image reconstruction for limited-angle inverse helical cone-beam computed tomography
    Yu, Wei
    Zeng, Li
    SCANNING, 2016, 38 (01) : 4 - 13
  • [37] Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
    Sidky, Emil Y.
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17): : 4777 - 4807
  • [38] Feasibility study of cone-beam computed tomography (CBCT) reconstruction algorithm for proton image-guided radiation therapy (IGRT)
    Han, Dong-Kyoon
    Jo, Byungdu
    Lee, Min-Hee
    Yoo, Myung Seok
    Kim, Kyuseok
    Lee, Youngjin
    OPTIK, 2016, 127 (20): : 9691 - 9694
  • [39] Cone-beam computed tomography (CBCT) dose optimization technique and image quality assessment scoring
    Trivedi, Gaurav
    Singh, Pushpendra P.
    Oinam, Arun S.
    Singh, Ranjit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (01) : 71 - 78
  • [40] Evaluation of radiation dose and image quality for dental cone-beam computed tomography in pediatric patients
    Ito, Misaki
    Chida, Koichi
    Onodera, Shu
    Kojima, Ikuho
    Iikubo, Masahiro
    Kato, Toshiki
    Fujisawa, Masaki
    Zuguchi, Masayuki
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (03)