Priori mask guided image reconstruction (p-MGIR) for ultra-low dose cone-beam computed tomography

被引:6
|
作者
Park, Justin C. [1 ]
Zhang, Hao [2 ]
Chen, Yunmei [2 ]
Fan, Qiyong [3 ]
Kahler, Darren L. [1 ]
Liu, Chihray [1 ]
Lu, Bo [1 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Math, Gainesville, FL 32611 USA
[3] Univ Nebraska Med Ctr, Dept Radiat Oncol, Omaha, NE 68105 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 21期
关键词
p-MGIR; 3DCBCT; iterative image reconstruction; compressed sensing; on-line IGRT; COMPRESSED SENSING ABOCS; CT RECONSTRUCTION; CANCER-RISKS; GPU; PROJECTION; ALGORITHM; NOISE;
D O I
10.1088/0031-9155/60/21/8505
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, the compressed sensing (CS) based iterative reconstruction method has received attention because of its ability to reconstruct cone beam computed tomography (CBCT) images with good quality using sparsely sampled or noisy projections, thus enabling dose reduction. However, some challenges remain. In particular, there is always a tradeoff between image resolution and noise/streak artifact reduction based on the amount of regularization weighting that is applied uniformly across the CBCT volume. The purpose of this study is to develop a novel low-dose CBCT reconstruction algorithm framework called priori mask guided image reconstruction (p-MGIR) that allows reconstruction of high-quality low-dose CBCT images while preserving the image resolution. In p-MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions: (1) where anatomical structures are complex, and (2) where intensities are relatively uniform. The priori mask, which is the key concept of the p-MGIR algorithm, was defined as the matrix that distinguishes between the two separate CBCT regions where the resolution needs to be preserved and where streak or noise needs to be suppressed. We then alternately updated each part of image by solving two sub-minimization problems iteratively, where one minimization was focused on preserving the edge information of the first part while the other concentrated on the removal of noise/artifacts from the latter part. To evaluate the performance of the p-MGIR algorithm, a numerical head-and-neck phantom, a Catphan 600 physical phantom, and a clinical head-and-neck cancer case were used for analysis. The results were compared with the standard Feldkamp-Davis-Kress as well as conventional CS-based algorithms. Examination of the p-MGIR algorithm showed that high-quality low-dose CBCT images can be reconstructed without compromising the image resolution. For both phantom and the patient cases, the p-MGIR is able to achieve a clinically-reasonable image with 60 projections. Therefore, a clinically-viable, high-resolution head-and-neck CBCT image can be obtained while cutting the dose by 83%. Moreover, the image quality obtained using p-MGIR is better than the quality obtained using other algorithms. In this work, we propose a novel low-dose CBCT reconstruction algorithm called p-MGIR. It can be potentially used as a CBCT reconstruction algorithm with low dose scan requests
引用
收藏
页码:8505 / 8524
页数:20
相关论文
共 50 条
  • [21] Dose and Image Quality of Cone-Beam Computed Tomography as Compared With Conventional Multislice Computed Tomography in Abdominal Imaging
    Schegerer, Alexander A.
    Lechel, Ursula
    Ritter, Manuel
    Weisser, Gerald
    Fink, Christian
    Brix, Gunnar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 675 - 684
  • [22] Cone-beam local tomography image reconstruction on chords
    Anastasio, Mark A.
    Sidky, E. Y.
    Zou, Y.
    Pan, X.
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [23] Local cone-beam tomography image reconstruction on chords
    Anastasio, Mark A.
    Zou, Yu
    Sidky, Emil Y.
    Pan, Xiaochuan
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (06) : 1569 - 1579
  • [24] Effects of Reconstruction Parameters on Image Noise and Spatial Resolution in Cone-beam Computed Tomography
    Lee, Seung-Wan
    Lee, Chang-Lae
    Cho, Hyo-Min
    Park, Hye-Suk
    Kim, Dae-Hong
    Choi, Yu-Na
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (04) : 2825 - 2832
  • [25] Cone-Beam Computed Tomography–Guided Percutaneous Radiologic Gastrostomy
    Markus Möhlenbruch
    Michael Nelles
    Daniel Thomas
    Winfried Willinek
    Andreas Gerstner
    Hans H. Schild
    Kai Wilhelm
    CardioVascular and Interventional Radiology, 2010, 33 : 315 - 320
  • [26] Fast, Iterative, Low-Dose, Cone-Beam Computed Tomography Reconstruction Using a Gradient Projection Algorithm
    Park, J.
    Song, B.
    Kim, J.
    Park, S.
    Kim, H.
    Suh, T.
    Liu, Z.
    Song, W.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [27] Tilting the jaw to improve the image quality or to reduce the dose in cone-beam computed tomography
    Luckow, Marlen
    Deyhle, Hans
    Beckmann, Felix
    Dagassan-Berndt, Dorothea
    Mueller, Bert
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E389 - E393
  • [28] In vitro accuracy of ultra-low dose cone-beam CT for detection of proximal caries
    Taeby, Aria
    Seyyedi, Seyyed Amir
    Mostafavi, Maryam
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (07) : 459 - 467
  • [29] GPU Based Ultra-Fast Monte Carlo Dose Calculation for Kilovoltage Cone-Beam Computed Tomography in Image-Guided Radiation Therapy
    Fujita, Y.
    Fujii, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E463 - E463
  • [30] Compensators for dose and scatter management in cone-beam computed tomography
    Graham, S. A.
    Moseley, D. J.
    Siewerdsen, J. H.