Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements

被引:116
|
作者
Ascenti, Giorgio [1 ]
Mileto, Achille [1 ]
Krauss, Bernhard [2 ]
Gaeta, Michele [1 ]
Blandino, Alfredo [1 ]
Scribano, Emanuele [1 ]
Settineri, Nicola [1 ]
Mazziotti, Silvio [1 ]
机构
[1] Policlin G Martino, Dipartimento Sci Radiol, I-98125 Messina, Italy
[2] Siemens AG, Healthcare Sect, Forchheim, Germany
关键词
Dual-energy CT; Renal masses; Standard enhancement measurements; Iodine quantification; Diagnostic accuracy; CYST PSEUDOENHANCEMENT; PHANTOM; LESIONS; BENIGN; SINGLE;
D O I
10.1007/s00330-013-2811-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the diagnostic accuracy of iodine quantification and standard enhancement measurements in distinguishing enhancing from nonenhancing renal masses. The Institutional Review Board approved this retrospective study conducted from data found in institutional patient databases and archives. Seventy-two renal masses were characterised as enhancing or nonenhancing using standard enhancement measurements (in HU) and iodine quantification (in mg/ml). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of standard enhancement measurements and iodine quantification were calculated from chi (2) tests of contingency with histopathology or imaging follow-up as the reference standard. Difference in accuracy was assessed by means of McNemar analysis. Sensitivity, specificity, PPV, NPV and diagnostic accuracy for standard enhancement measurements and iodine quantification were 77.7 %, 100 %, 100 %, 81.8 %, 89 % and 100 %, 94.4 %, 94.7, 100 % and 97 %, respectively. The McNemar analysis showed that the accuracy of iodine quantification was significantly better (P < 0.001) than that of standard enhancement measurements. Compared with standard enhancement measurements, whole-tumour iodine quantification is more accurate in distinguishing enhancing from nonenhancing renal masses.
引用
收藏
页码:2288 / 2295
页数:8
相关论文
共 50 条
  • [41] Technical Note: Insertion of digital lesions in the projection domain for dual-source, dual-energy CT
    Ferrero, Andrea
    Chen, Baiyu
    Li, Zhoubo
    Yu, Lifeng
    McCollough, Cynthia
    MEDICAL PHYSICS, 2017, 44 (05) : 1655 - 1660
  • [42] Abdominal dual-source dual-energy CT: Uses in clinical practice (vol 42, 2013)
    Siegel, Marilyn J.
    APPLIED RADIOLOGY, 2013, 42 (12) : 2 - 2
  • [43] Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration
    Primak, A. N.
    Ramirez Giraldo, J. C.
    Liu, X.
    Yu, L.
    McCollough, C. H.
    MEDICAL PHYSICS, 2009, 36 (04) : 1359 - 1369
  • [44] Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality
    Yu, Lifeng
    Christner, Jodie A.
    Leng, Shuai
    Wang, Jia
    Fletcher, Joel G.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (12) : 6371 - 6379
  • [45] X-Ray Spectra Optimization for Dual-Energy Imaging Using Dual-Source CT
    Giraldo, J. Ramirez
    Primak, A.
    Liu, X.
    McCollough, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [46] Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT
    Yu, Lifeng
    Primak, Andrew N.
    Liu, Xin
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2009, 36 (03) : 1019 - 1024
  • [47] Feasibility and Accuracy of Dual-Source Dual-Energy CT for Noninvasive Determination of Hepatic Iron Accumulation
    Joe, Eugene
    Kim, Se Hyung
    Lee, Kyoung Bun
    Jang, Ja-June
    Lee, Jae Young
    Lee, Jeong Min
    Han, Joon Koo
    Choi, Byung Ihn
    RADIOLOGY, 2012, 262 (01) : 126 - 135
  • [48] Virtual monochromatic imaging in dual-source and dual-energy CT for visualization of acute ischemic stroke
    Hidetake Hara
    Hiroshi Muraishi
    Hiroki Matsuzawa
    Toshiyuki Inoue
    Yasuo Nakajima
    Hitoshi Satoh
    Shinji Abe
    Journal of the Korean Physical Society, 2015, 67 : 103 - 107
  • [49] Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual-Energy CT Projection Data
    Ferrero, A.
    Chen, B.
    Huang, A.
    Montoya, J.
    Yu, L.
    McCollough, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3658 - 3659
  • [50] Dual-energy CT Aortography with 50% Reduced Iodine Dose, Versus Single-energy CT Aortography with Standard Iodine Dose
    Shuman, William P.
    Chan, Keith T.
    Busey, Janet M.
    Mitsumori, Lee M.
    Koprowicz, Kent M.
    ACADEMIC RADIOLOGY, 2016, 23 (05) : 611 - 618