Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements

被引:116
|
作者
Ascenti, Giorgio [1 ]
Mileto, Achille [1 ]
Krauss, Bernhard [2 ]
Gaeta, Michele [1 ]
Blandino, Alfredo [1 ]
Scribano, Emanuele [1 ]
Settineri, Nicola [1 ]
Mazziotti, Silvio [1 ]
机构
[1] Policlin G Martino, Dipartimento Sci Radiol, I-98125 Messina, Italy
[2] Siemens AG, Healthcare Sect, Forchheim, Germany
关键词
Dual-energy CT; Renal masses; Standard enhancement measurements; Iodine quantification; Diagnostic accuracy; CYST PSEUDOENHANCEMENT; PHANTOM; LESIONS; BENIGN; SINGLE;
D O I
10.1007/s00330-013-2811-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the diagnostic accuracy of iodine quantification and standard enhancement measurements in distinguishing enhancing from nonenhancing renal masses. The Institutional Review Board approved this retrospective study conducted from data found in institutional patient databases and archives. Seventy-two renal masses were characterised as enhancing or nonenhancing using standard enhancement measurements (in HU) and iodine quantification (in mg/ml). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of standard enhancement measurements and iodine quantification were calculated from chi (2) tests of contingency with histopathology or imaging follow-up as the reference standard. Difference in accuracy was assessed by means of McNemar analysis. Sensitivity, specificity, PPV, NPV and diagnostic accuracy for standard enhancement measurements and iodine quantification were 77.7 %, 100 %, 100 %, 81.8 %, 89 % and 100 %, 94.4 %, 94.7, 100 % and 97 %, respectively. The McNemar analysis showed that the accuracy of iodine quantification was significantly better (P < 0.001) than that of standard enhancement measurements. Compared with standard enhancement measurements, whole-tumour iodine quantification is more accurate in distinguishing enhancing from nonenhancing renal masses.
引用
收藏
页码:2288 / 2295
页数:8
相关论文
共 50 条
  • [31] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Long-Jiang Zhang
    Jin Peng
    Sheng-Yong Wu
    Z. Jane Wang
    Xin-Sheng Wu
    Chang-Sheng Zhou
    Xue-Man Ji
    Guang-Ming Lu
    European Radiology, 2010, 20 : 2257 - 2264
  • [32] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Zhang, Long-Jiang
    Peng, Jin
    Wu, Sheng-Yong
    Wang, Z. Jane
    Wu, Xin-Sheng
    Zhou, Chang-Sheng
    Ji, Xue-Man
    Lu, Guang-Ming
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2257 - 2264
  • [33] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Goo, Hyun Woo
    PEDIATRIC RADIOLOGY, 2010, 40 (09) : 1536 - 1544
  • [34] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Hyun Woo Goo
    Pediatric Radiology, 2010, 40 : 1536 - 1544
  • [35] Performance of Dual-Energy CT with Tin Filter Technology for the Discrimination of Renal Cysts and Enhancing Masses
    Leschka, Sebastian
    Stolzmann, Paul
    Baumueller, Stephan
    Scheffel, Hans
    Desbiolles, Lotus
    Schmid, Bernhard
    Marincek, Borut
    Alkadhi, Hatem
    ACADEMIC RADIOLOGY, 2010, 17 (04) : 526 - 534
  • [36] Iodine and Fat Quantification for Differentiation of Adrenal Gland Adenomas From Metastases Using Third-Generation Dual-Source Dual-Energy Computed Tomography
    Martin, Simon S.
    Weidinger, Sebastian
    Czwikla, Rouben
    Kaltenbach, Benjamin
    Albrecht, Moritz H.
    Lenga, Lukas
    Vogl, Thomas J.
    Wichmann, Julian L.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (03) : 173 - 178
  • [37] Spectral performance for iodine quantification of a dual-source, dual-kV photon counting detector CT
    Winfree, Tim
    Treb, Kevin
    Mccollough, Cynthia
    Leng, Shuai
    MEDICAL PHYSICS, 2025,
  • [38] Dual-energy CT iodine quantification for characterizing focal thyroid lesions
    Lee, Do Hyung
    Lee, Young Hen
    Seo, Hyung Suk
    Lee, Ki Yeol
    Suh, Sang-il
    Ryoo, Inseon
    You, Sung-Hye
    Kim, Byungjun
    Yang, Kyung-Sook
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (04): : 1024 - 1031
  • [39] Virtual Monochromatic Imaging in Dual-source and Dual-energy CT for Visualization of Acute Ischemic Stroke
    Hara, Hidetake
    Muraishi, Hiroshi
    Matsuzawa, Hiroki
    Inoue, Toshiyuki
    Nakajima, Yasuo
    Satoh, Hitoshi
    Abe, Shinji
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 103 - 107
  • [40] Quantification of iodine concentration by dual-energy CT in patients with acute pancreatitis
    Utrera Perez, E.
    Tardaguila de la Fuente, G.
    Martinez Rodriguez, C.
    Villanueva Campos, A.
    Jurado Basildo, C.
    Garcia Pouton, N.
    RADIOLOGIA, 2020, 62 (05): : 360 - 364