External Calibration of the Spectral Coverage for Three-Dimensional Multispectral MRI

被引:19
|
作者
Kaushik, S. Sivaram [1 ]
Marszalkowski, Cathy [2 ]
Koch, Kevin M. [1 ,2 ]
机构
[1] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Dept Radiol, 8700 W Wisconsin Ave, Milwaukee, WI 53226 USA
关键词
spectral-calibration; MAVRIC-SL; frequency map; 3D-MSI; METAL ARTIFACT CORRECTION; FAST SPIN-ECHO; HIP-ARTHROPLASTY; IMPLANTS; IMPACT;
D O I
10.1002/mrm.26065
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: By combining images created at distinct frequency offsets from the Larmor frequency, three-dimensional (3D) multispectral imaging (3D-MSI) sequences help overcome the large spatial frequency dispersion caused by metal implants. This frequency dispersion, however, varies with the implant size, orientation, and composition. Using a MAVRIC 3D-MSI acquisition, we sought to prospectively calibrate the spectral coverage needed for 3D-MSI scans. This calibration should offer a significant improvement to image quality, and reduce the scan time. Methods: The 24 spectral bins from the calibration scan were used to generate a map of frequency offsets around the implant. The magnitude image was used to remove any outliers in the associated frequency offset map, and this processed map was used to determine the cutoff frequency offset and, hence, number of spectral bins. This approach was tested in 13 subjects, by retrospectively reconstructing MAVRIC-SL images with fewer spectral bins. Subsequently, the spectral coverage for MAVRIC-SL images was prospectively calibrated in six subjects, and based on the cutoff frequency offset, these images were acquired with fewer spectral bins. Results: With fewer spectral bins, both retrospectively and prospectively calibrated MAVRIC-SL images adequately delineated the implant boundary. Conclusion: Incorporating this calibration procedure into future 3D-MSI exams will help improve image signal-to-noise ratio, reduce scan time, and significantly improve clinical workflow when imaging near orthopedic implants. (C) 2015 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1494 / 1503
页数:10
相关论文
共 50 条
  • [41] Calibration of Fringe Projection Three-Dimensional Measurement System
    Nian, Xu
    Wu Jianwei
    Wei Xiaobao
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (01)
  • [42] Three-dimensional calibration of micromanipulators using stereo vision
    Yi Xiong
    Juha Hirvonen
    Pasi Kallio
    Journal of Micro-Bio Robotics, 2013, 8 (1) : 13 - 24
  • [43] A Research on Three-Dimensional Measurement and Calibration Techniques for Boating
    Cai, Lingli
    Pan, Huiju
    PROCEEDINGS OF SECOND INTERNATIONAL CONFERENCE ON SPORTS SCIENCE AND SPORTS ENGINEERING, 2009, : 371 - 374
  • [44] Backward automatic calibration for three-dimensional landslide models
    Giacomo Titti
    Giulia Bossi
    Gordon G.D.Zhou
    Gianluca Marcato
    Alessandro Pasuto
    Geoscience Frontiers, 2021, 12 (01) : 231 - 241
  • [45] Three-dimensional calibration targets for optical coherence tomography
    Sandrian, Michelle Gabriele
    Tomlins, Pete
    Woolliams, Peter
    Rasakanthan, Janarthanan
    Lee, Graham C. B.
    Yang, Anna
    Povazay, Boris
    Alex, Aneesh
    Sugden, Kate
    Drexler, Wolfgang
    OPTICAL DIAGNOSTICS AND SENSING XII: TOWARD POINT-OF-CARE DIAGNOSTICS AND DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE IV, 2012, 8229
  • [46] Camera calibration for anamorphic lenses with three-dimensional targets
    Zhang, Jinkai
    Wang, Xue
    Ma, Mengmeng
    Li, Fajia
    Liu, Haining
    Cui, Huanyong
    APPLIED OPTICS, 2020, 59 (02) : 324 - 332
  • [47] Three-dimensional calibration of micromanipulators using stereo vision
    Xiong, Yi
    Hirvonen, Juha
    Kallio, Pasi
    JOURNAL OF MICRO-BIO ROBOTICS, 2013, 8 (01) : 13 - 24
  • [48] A three-dimensional baseline calibration method of spaceborne InSAR
    Chen, G. (splitter@sina.com), 1600, Editorial Board of Medical Journal of Wuhan University (39):
  • [49] Accelerated three-dimensional multispectral MRI with robust principal component analysis for separation of on- and off-resonance signals
    Levine, Evan
    Stevens, Kathryn
    Beaulieu, Christopher
    Hargreaves, Brian
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1495 - 1505
  • [50] Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI
    Gunzinger J.M.
    Delso G.
    Boss A.
    Porto M.
    Davison H.
    von Schulthess G.K.
    Huellner M.
    Stolzmann P.
    Veit-Haibach P.
    Burger I.A.
    EJNMMI Physics, 1 (1) : 1 - 14