Reliability of microvascular responsiveness measures derived from near-infrared spectroscopy across a variety of ischemic periods in young and older individuals

被引:45
|
作者
Iannetta, Danilo [1 ]
Inglis, Erin Calaine [1 ]
Soares, Rogerio N. [1 ,2 ]
McLay, Kaitlin M. [1 ]
Pogliaghi, Silvia [2 ]
Murias, Juan M. [1 ]
机构
[1] Univ Calgary, Fac Kinesiol, Calgary, AB T2N 1N4, Canada
[2] Univ Verona, Dept Neurol & Movement Sci, Verona, Italy
基金
加拿大自然科学与工程研究理事会;
关键词
Test-to-test reliability; Day-to-day reliability; Oxygen saturation; Reactive hyperemia; Vasodilation; FLOW-MEDIATED DILATION; VASCULAR RESPONSIVENESS; ENDOTHELIAL DYSFUNCTION; NITRIC-OXIDE; REPRODUCIBILITY; ACETYLCHOLINE; VASODILATION; RESPONSES; CHILDREN; IMPROVES;
D O I
10.1016/j.mvr.2018.10.001
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Cardiovascular disease (CVD) is associated with impairments in microvascular responsiveness. Therefore, reliably assessing microvascular function is clinically relevant. Thus, this study aimed to examine the reliability of the near-infrared spectroscopy (NIRS)-derived oxygen saturation (StO(2)) reperfusion slope, a measure of microvascular responsiveness, to four different vascular occlusion tests (VOT) of different durations in young and older participants. Methods: Eight healthy young (29 +/- 5 yr) and seven older (67 +/- 4 yr) men participated in four NIRS combined with VOT (NIRS-VOT; 30 s, 1, 3, and 5 min) in the leg microvasculature on two visits separated by 1-2 weeks. Vascular responsiveness was determined by the StO(2) reperfusion slope. The coefficient of variation (CV), repeatability, reliability (ICC), and the limits of agreement (LOA) were calculated for the NIRS-derived reperfusion slopes for each occlusion duration and visit. Results: CV for the StO(2) reperfusion slope following 30 s, 1, 3 and 5 min of occlusion were 33 +/- 29%, 19 +/- 21%, 14 +/- 12%, and 12 +/- 10%, respectively. Repeatability values following 30 s, 1, 3 and 5 min occlusions were 20%, 1%, 4% and 21%, respectively. The ICC for the St0 2 reperfusion slopes for each occlusion duration were 0.29, 0.42, 0.84, and 0.88 following 30 s, 1, 3 and 5 min of occlusion, respectively. LOA values between visit 1 and 2 for occlusions were not different from zero. There were no age-related differences for all variables of the study. Conclusion: NIBS-derived StO(2) reperfusion slope, has good reliability across a range of occlusion durations with the strongest reliability during longer occlusion durations.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 50 条
  • [41] Weak network efficiency in young children with Autism Spectrum Disorder: Evidence from a functional near-infrared spectroscopy study
    Li, Yanwei
    Yu, Dongchuan
    BRAIN AND COGNITION, 2016, 108 : 47 - 55
  • [42] Measuring Near-Infrared Spectroscopy Derived Cerebral Autoregulation in Neonates: From Research Tool Toward Bedside Multimodal Monitoring
    Thewissen, Liesbeth
    Caicedo, Alexander
    Lemmers, Petra
    Van Bel, Frank
    Van Huffel, Sabine
    Naulaers, Gunnar
    FRONTIERS IN PEDIATRICS, 2018, 6
  • [43] Near-infrared reactance spectroscopy-derived visceral adipose tissue for the assessment of metabolic syndrome in a multi-ethnic sample of young adults
    Graybeal, Austin J.
    Brandner, Caleb F.
    Wise, Havens L.
    Henderson, Alex
    Aultman, Ryan S.
    Vallecillo-Bustos, Anabelle
    Newsome, Ta' Quoris A.
    Stanfield, Diavion
    Stavres, Jon
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 2024, 36 (10)
  • [44] Reliability Evaluation for Continuous-Wave Functional Near-Infrared Spectroscopy Systems: Comprehensive Testing from Bench Characterization to Human Test
    Gao, Chenyang
    Xiu, Jia
    Huang, Chong
    Ma, Kaixue
    Li, Ting
    SENSORS, 2024, 24 (07)
  • [45] Skin blood flow differentially affects near-infrared spectroscopy-derived measures of muscle oxygen saturation and blood volume at rest and during dynamic leg exercise
    Tew, Garry A.
    Ruddock, Alan D.
    Saxton, John M.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 110 (05) : 1083 - 1089
  • [46] Skin blood flow differentially affects near-infrared spectroscopy-derived measures of muscle oxygen saturation and blood volume at rest and during dynamic leg exercise
    Garry A. Tew
    Alan D. Ruddock
    John M. Saxton
    European Journal of Applied Physiology, 2010, 110 : 1083 - 1089
  • [47] Feature importance measures from random forest regressor using near-infrared spectra for predicting carbonization characteristics of kraft lignin-derived hydrochar
    Sung-Wook Hwang
    Hyunwoo Chung
    Taekyeong Lee
    Jungkyu Kim
    YunJin Kim
    Jong-Chan Kim
    Hyo Won Kwak
    In-Gyu Choi
    Hwanmyeong Yeo
    Journal of Wood Science, 69
  • [48] The impact of lipid rich plaque on coronary-microvascular-dysfunction evaluated by near-infrared spectroscopy IVUS and angiography-derived index of microcirculatory resistance after percutaneous-coron
    Yamada, N.
    Ueno, M.
    Onishi, K.
    Sugimoto, K.
    Kakehi, K.
    Fujita, K.
    Nakazawa, G.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [49] The impact of lipid rich plaque on coronary-microvascular-dysfunction evaluated by near-infrared spectroscopy IVUS and angiography-derived index of microcirculatory resistance after percutaneous-coron
    Yamada, N.
    Ueno, M.
    Onishi, K.
    Sugimoto, K.
    Kakehi, K.
    Fujita, K.
    Nakazawa, G.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [50] Feature importance measures from random forest regressor using near-infrared spectra for predicting carbonization characteristics of kraft lignin-derived hydrochar
    Hwang, Sung-Wook
    Chung, Hyunwoo
    Lee, Taekyeong
    Kim, Jungkyu
    Kim, YunJin
    Kim, Jong-Chan
    Kwak, Hyo Won
    Choi, In-Gyu
    Yeo, Hwanmyeong
    JOURNAL OF WOOD SCIENCE, 2023, 69 (01)