共 50 条
Reliability of microvascular responsiveness measures derived from near-infrared spectroscopy across a variety of ischemic periods in young and older individuals
被引:45
|作者:
Iannetta, Danilo
[1
]
Inglis, Erin Calaine
[1
]
Soares, Rogerio N.
[1
,2
]
McLay, Kaitlin M.
[1
]
Pogliaghi, Silvia
[2
]
Murias, Juan M.
[1
]
机构:
[1] Univ Calgary, Fac Kinesiol, Calgary, AB T2N 1N4, Canada
[2] Univ Verona, Dept Neurol & Movement Sci, Verona, Italy
基金:
加拿大自然科学与工程研究理事会;
关键词:
Test-to-test reliability;
Day-to-day reliability;
Oxygen saturation;
Reactive hyperemia;
Vasodilation;
FLOW-MEDIATED DILATION;
VASCULAR RESPONSIVENESS;
ENDOTHELIAL DYSFUNCTION;
NITRIC-OXIDE;
REPRODUCIBILITY;
ACETYLCHOLINE;
VASODILATION;
RESPONSES;
CHILDREN;
IMPROVES;
D O I:
10.1016/j.mvr.2018.10.001
中图分类号:
R6 [外科学];
学科分类号:
1002 ;
100210 ;
摘要:
Background: Cardiovascular disease (CVD) is associated with impairments in microvascular responsiveness. Therefore, reliably assessing microvascular function is clinically relevant. Thus, this study aimed to examine the reliability of the near-infrared spectroscopy (NIRS)-derived oxygen saturation (StO(2)) reperfusion slope, a measure of microvascular responsiveness, to four different vascular occlusion tests (VOT) of different durations in young and older participants. Methods: Eight healthy young (29 +/- 5 yr) and seven older (67 +/- 4 yr) men participated in four NIRS combined with VOT (NIRS-VOT; 30 s, 1, 3, and 5 min) in the leg microvasculature on two visits separated by 1-2 weeks. Vascular responsiveness was determined by the StO(2) reperfusion slope. The coefficient of variation (CV), repeatability, reliability (ICC), and the limits of agreement (LOA) were calculated for the NIRS-derived reperfusion slopes for each occlusion duration and visit. Results: CV for the StO(2) reperfusion slope following 30 s, 1, 3 and 5 min of occlusion were 33 +/- 29%, 19 +/- 21%, 14 +/- 12%, and 12 +/- 10%, respectively. Repeatability values following 30 s, 1, 3 and 5 min occlusions were 20%, 1%, 4% and 21%, respectively. The ICC for the St0 2 reperfusion slopes for each occlusion duration were 0.29, 0.42, 0.84, and 0.88 following 30 s, 1, 3 and 5 min of occlusion, respectively. LOA values between visit 1 and 2 for occlusions were not different from zero. There were no age-related differences for all variables of the study. Conclusion: NIBS-derived StO(2) reperfusion slope, has good reliability across a range of occlusion durations with the strongest reliability during longer occlusion durations.
引用
收藏
页码:117 / 124
页数:8
相关论文