Reliability of microvascular responsiveness measures derived from near-infrared spectroscopy across a variety of ischemic periods in young and older individuals

被引:45
|
作者
Iannetta, Danilo [1 ]
Inglis, Erin Calaine [1 ]
Soares, Rogerio N. [1 ,2 ]
McLay, Kaitlin M. [1 ]
Pogliaghi, Silvia [2 ]
Murias, Juan M. [1 ]
机构
[1] Univ Calgary, Fac Kinesiol, Calgary, AB T2N 1N4, Canada
[2] Univ Verona, Dept Neurol & Movement Sci, Verona, Italy
基金
加拿大自然科学与工程研究理事会;
关键词
Test-to-test reliability; Day-to-day reliability; Oxygen saturation; Reactive hyperemia; Vasodilation; FLOW-MEDIATED DILATION; VASCULAR RESPONSIVENESS; ENDOTHELIAL DYSFUNCTION; NITRIC-OXIDE; REPRODUCIBILITY; ACETYLCHOLINE; VASODILATION; RESPONSES; CHILDREN; IMPROVES;
D O I
10.1016/j.mvr.2018.10.001
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Cardiovascular disease (CVD) is associated with impairments in microvascular responsiveness. Therefore, reliably assessing microvascular function is clinically relevant. Thus, this study aimed to examine the reliability of the near-infrared spectroscopy (NIRS)-derived oxygen saturation (StO(2)) reperfusion slope, a measure of microvascular responsiveness, to four different vascular occlusion tests (VOT) of different durations in young and older participants. Methods: Eight healthy young (29 +/- 5 yr) and seven older (67 +/- 4 yr) men participated in four NIRS combined with VOT (NIRS-VOT; 30 s, 1, 3, and 5 min) in the leg microvasculature on two visits separated by 1-2 weeks. Vascular responsiveness was determined by the StO(2) reperfusion slope. The coefficient of variation (CV), repeatability, reliability (ICC), and the limits of agreement (LOA) were calculated for the NIRS-derived reperfusion slopes for each occlusion duration and visit. Results: CV for the StO(2) reperfusion slope following 30 s, 1, 3 and 5 min of occlusion were 33 +/- 29%, 19 +/- 21%, 14 +/- 12%, and 12 +/- 10%, respectively. Repeatability values following 30 s, 1, 3 and 5 min occlusions were 20%, 1%, 4% and 21%, respectively. The ICC for the St0 2 reperfusion slopes for each occlusion duration were 0.29, 0.42, 0.84, and 0.88 following 30 s, 1, 3 and 5 min of occlusion, respectively. LOA values between visit 1 and 2 for occlusions were not different from zero. There were no age-related differences for all variables of the study. Conclusion: NIBS-derived StO(2) reperfusion slope, has good reliability across a range of occlusion durations with the strongest reliability during longer occlusion durations.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 50 条
  • [21] Predictive ability of lipdic burden for FFR-derived physiological measures: insights from near-infrared spectroscopy imaging analysis
    Murai, K.
    Kataoka, Y.
    Hirayama, A.
    Hosoda, H.
    Nakashima, T.
    Honda, S.
    Fujino, M.
    Nakao, K.
    Yoneda, S.
    Otsuka, F.
    Nishihira, K.
    Kanaya, T.
    Asaumi, Y.
    Noguchi, T.
    Yasuda, S.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3506 - 3506
  • [22] Stress assessment by means of heart rate derived from functional near-infrared spectroscopy
    Hakimi, Naser
    Setarehdan, Seyed Kamaledin
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (11)
  • [23] Does sex influence near-infrared spectroscopy-derived indicators of microvascular reactivity and the response to acute dietary capsaicin
    Zaleski, Kendall
    Matias, Alexs
    Gyampo, Abena
    Giuriato, Gaia
    Lynch, Meaghan
    Lora, Brian
    Tomasi, Tawn
    Basso, Emma
    Finegan, Emma
    Schickler, Jack
    Venturelli, Massimo
    Ives, Stephen J.
    MICROVASCULAR RESEARCH, 2023, 145
  • [24] The association between near-infrared spectroscopy-derived and flow-mediated dilation assessment of vascular responsiveness in the arm
    Soares, Rogerio N.
    Somani, Yasina B.
    Proctor, David N.
    Murias, Juan M.
    MICROVASCULAR RESEARCH, 2019, 122 : 41 - 44
  • [25] Development of Cognitive Shifting from Others' Behavior in Young Children: A Near-infrared Spectroscopy Study
    Moriguchi, Yusuke
    Sakata, Chifumi
    DEVELOPMENTAL NEUROPSYCHOLOGY, 2020, 45 (01) : 39 - 47
  • [26] Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor
    Feldmann, Andri
    Schmitz, Roger
    Erlacher, Daniel
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (11)
  • [27] Reliability of muscle blood flow and oxygen consumption response from exercise using near-infrared spectroscopy
    Lucero, Adam A.
    Addae, Gifty
    Lawrence, Wayne
    Neway, Beemnet
    Credeur, Daniel P.
    Faulkner, James
    Rowlands, David
    Stoner, Lee
    EXPERIMENTAL PHYSIOLOGY, 2018, 103 (01) : 90 - 100
  • [28] Whole-cortical graphical networks at wakeful rest in young and older adults revealed by functional near-infrared spectroscopy
    Li, Lin
    Babawale, Olajide
    Yennu, Amarnath
    Trowbridge, Cynthia
    Hulla, Ryan
    Gatchel, Robert J.
    Liu, Hanli
    NEUROPHOTONICS, 2018, 5 (03)
  • [29] Reliability and Convergent Validity of Endurance Indices Derived from Near-Infrared Spectroscopy and Electromyography during a Bilateral Hanging Task in Amateur Rock Climbers
    Kwong, Wai-Hang
    Li, Jia-Qi
    Lui, Chun-Hung
    Luk, Hiu-Tung
    Lau, King-Fung
    Seaby, Ray
    Sidarta, Ananda
    JOURNAL OF FUNCTIONAL MORPHOLOGY AND KINESIOLOGY, 2024, 9 (03)
  • [30] Evaluating motion processing algorithms for use with functional near-infrared spectroscopy data from young children
    Reyes, Lourdes M. Delgado
    Bohache, Kevin
    Wijeakumar, Sobanawartiny
    Spencer, John P.
    NEUROPHOTONICS, 2018, 5 (02)