Reliability of microvascular responsiveness measures derived from near-infrared spectroscopy across a variety of ischemic periods in young and older individuals

被引:45
|
作者
Iannetta, Danilo [1 ]
Inglis, Erin Calaine [1 ]
Soares, Rogerio N. [1 ,2 ]
McLay, Kaitlin M. [1 ]
Pogliaghi, Silvia [2 ]
Murias, Juan M. [1 ]
机构
[1] Univ Calgary, Fac Kinesiol, Calgary, AB T2N 1N4, Canada
[2] Univ Verona, Dept Neurol & Movement Sci, Verona, Italy
基金
加拿大自然科学与工程研究理事会;
关键词
Test-to-test reliability; Day-to-day reliability; Oxygen saturation; Reactive hyperemia; Vasodilation; FLOW-MEDIATED DILATION; VASCULAR RESPONSIVENESS; ENDOTHELIAL DYSFUNCTION; NITRIC-OXIDE; REPRODUCIBILITY; ACETYLCHOLINE; VASODILATION; RESPONSES; CHILDREN; IMPROVES;
D O I
10.1016/j.mvr.2018.10.001
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Cardiovascular disease (CVD) is associated with impairments in microvascular responsiveness. Therefore, reliably assessing microvascular function is clinically relevant. Thus, this study aimed to examine the reliability of the near-infrared spectroscopy (NIRS)-derived oxygen saturation (StO(2)) reperfusion slope, a measure of microvascular responsiveness, to four different vascular occlusion tests (VOT) of different durations in young and older participants. Methods: Eight healthy young (29 +/- 5 yr) and seven older (67 +/- 4 yr) men participated in four NIRS combined with VOT (NIRS-VOT; 30 s, 1, 3, and 5 min) in the leg microvasculature on two visits separated by 1-2 weeks. Vascular responsiveness was determined by the StO(2) reperfusion slope. The coefficient of variation (CV), repeatability, reliability (ICC), and the limits of agreement (LOA) were calculated for the NIRS-derived reperfusion slopes for each occlusion duration and visit. Results: CV for the StO(2) reperfusion slope following 30 s, 1, 3 and 5 min of occlusion were 33 +/- 29%, 19 +/- 21%, 14 +/- 12%, and 12 +/- 10%, respectively. Repeatability values following 30 s, 1, 3 and 5 min occlusions were 20%, 1%, 4% and 21%, respectively. The ICC for the St0 2 reperfusion slopes for each occlusion duration were 0.29, 0.42, 0.84, and 0.88 following 30 s, 1, 3 and 5 min of occlusion, respectively. LOA values between visit 1 and 2 for occlusions were not different from zero. There were no age-related differences for all variables of the study. Conclusion: NIBS-derived StO(2) reperfusion slope, has good reliability across a range of occlusion durations with the strongest reliability during longer occlusion durations.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 50 条
  • [1] Repeatability of vascular responsiveness measures derived from near-infrared spectroscopy
    Mclay, Kaitlin M.
    Nederveen, Josh P.
    Pogliaghi, Silvia
    Paterson, Donald H.
    Murias, Juan M.
    PHYSIOLOGICAL REPORTS, 2016, 4 (09): : 1 - 8
  • [2] The Association Between Contrast-Enhanced Ultrasound and Near-Infrared Spectroscopy-Derived Measures of Calf Muscle Microvascular Responsiveness in Older Adults
    Young, Grace M.
    Krastins, Digby
    Chang, David
    Lam, Jeng
    Quah, Jing
    Stanton, Tony
    Russell, Fraser
    Greaves, Kim
    Kriel, Yuri
    Askew, Christopher D.
    HEART LUNG AND CIRCULATION, 2021, 30 (11): : 1726 - 1733
  • [3] RELIABILITY OF NEAR-INFRARED SPECTROSCOPY IN THE EVALUATION OF FOREARM MICROVASCULAR FUNCTION
    Lacroix, S.
    Gayda, M.
    Gremeaux, V.
    Juneau, M.
    Nigam, A.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S89 - S89
  • [4] Vascular responsiveness determined by near-infrared spectroscopy measures of oxygen saturation
    Mclay, Kaitlin M.
    Fontana, Federico Y.
    Nederveen, Josh P.
    Guida, Federico F.
    Paterson, Donald H.
    Pogliaghi, Silvia
    Murias, Juan M.
    EXPERIMENTAL PHYSIOLOGY, 2016, 101 (01) : 34 - 40
  • [5] Effect of Acute Increases in Retrograde Shear on Near-Infrared Spectroscopy Derived Microvascular Reactivity
    Ramos, Macarena
    Black, Christopher D.
    Branch, Patrece A.
    Caldwell, Jacob T.
    Wardlow, Garrett C.
    Ade, Carl J.
    FASEB JOURNAL, 2017, 31
  • [6] Near-infrared spectroscopy detects transient decrements and recovery of microvascular responsiveness following prolonged forearm ischemia
    Soares, Rogerio N.
    Somani, Yasina B.
    Al-Qahtani, Ahmad M.
    Proctor, David N.
    Murias, Juan M.
    MICROVASCULAR RESEARCH, 2019, 125
  • [7] Muscle Oxygenation and Microvascular Reactivity Across Different Stages of CKD: A Near-Infrared Spectroscopy Study
    Theodorakopoulou, Marieta P.
    Zafeiridis, Andreas
    Dipla, Konstantina
    Faitatzidou, Danai
    Koutlas, Angelos
    Alexandrou, Maria-Eleni
    Doumas, Michael
    Papagianni, Aikaterini
    Sarafidis, Pantelis
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2023, 81 (06) : 655 - +
  • [8] Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold
    van der Zwaard, Stephan
    Jaspers, Richard T.
    Blokland, Ilse J.
    Achterberg, Chantal
    Visser, Jurrian M.
    den Uil, Anne R.
    Hofmijster, Mathijs J.
    Levels, Koen
    Noordhof, Dionne A.
    de Haan, Arnold
    de Koning, Jos J.
    van der Laarse, Willem J.
    de Ruiter, Cornelis J.
    PLOS ONE, 2016, 11 (09):
  • [9] Reliability of brain metrics derived from a Time-Domain Functional Near-Infrared Spectroscopy System
    Dubois, Julien
    Field, Ryan M.
    Jawhar, Sami
    Koch, Erin M.
    Aghajan, Zahra M.
    Miller, Naomi
    Perdue, Katherine L.
    Taylor, Moriah
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [10] Microvascular responses during reactive hyperemia assessed by near-infrared spectroscopy and arterial stiffness in young, middle-aged, and older women
    Horiuchi, Masahiro
    Okita, Koichi
    MICROVASCULAR RESEARCH, 2020, 129