The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific assessment of the observational capabilities in the hard X-ray band

被引:4
|
作者
D'Andrea, M. [1 ,2 ]
Lotti, S. [1 ]
Macculi, C. [1 ]
Piro, L. [1 ]
Argan, A. [1 ]
Gatti, F. [3 ]
机构
[1] INAF IAPS Roma, Via Fosso del Cavaliere 100, I-00133 Rome, Italy
[2] Univ Roma Tor Vergata, Dept Phys, Via Ric Sci 1, I-00133 Rome, Italy
[3] Univ Genoa, Dept Phys, Via Dodecaneso 33, I-16146 Genoa, Italy
关键词
X-rays: detectors; ATHENA; X-IFU; Anticoincidence detectors; ENERGY;
D O I
10.1007/s10686-017-9543-4
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028 towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a cryogenic spectrometer based on a large array of TES microcalorimeters, able to perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6 keV). The X-IFU sensitivity is highly degraded by the particle background expected in the L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the particle background level and enable the mission science goals, the instrument incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES based detector, placed < 1 mm below the main array. In this paper we report a scientific assessment of the CryoAC observational capabilities in the hard X-ray band (E > 10 keV). The aim of the study has been to understand if the present detector design can be improved in order to enlarge the X-IFU scientific capability on an energy band wider than the TES array. This is beyond the CryoAC baseline, being this instrument aimed to operate as anticoincidence particle detector and not conceived to perform X-ray observations.
引用
收藏
页码:359 / 370
页数:12
相关论文
共 50 条
  • [1] The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific assessment of the observational capabilities in the hard X-ray band
    M. D’Andrea
    S. Lotti
    C. Macculi
    L. Piro
    A. Argan
    F. Gatti
    Experimental Astronomy, 2017, 44 : 359 - 370
  • [2] The Cryogenic AntiCoincidence Detector for ATHENA X-IFU: The Project Status
    Macculi, C.
    Argan, A.
    Brienza, D.
    D'Andrea, M.
    Lotti, S.
    Minervini, G.
    Piro, L.
    Biasotti, M.
    Barusso, L.
    Gatti, F.
    Rigano, M.
    Torrioli, G.
    Fiorini, M.
    Molendi, S.
    Uslenghi, M.
    Cavazzuti, E.
    Volpe, A.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2020, 199 (1-2) : 416 - 424
  • [3] The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
    D'Andrea, M.
    Macculi, C.
    Torrioli, G.
    Argan, A.
    Brienza, D.
    Lotti, S.
    Minervini, G.
    Piro, L.
    Biasotti, M.
    Barusso, L. Ferrari
    Gatti, F.
    Rigano, M.
    Volpe, A.
    Battistelli, E. S.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2020, 199 (1-2) : 65 - 72
  • [4] The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector
    M. D’Andrea
    C. Macculi
    G. Torrioli
    A. Argan
    D. Brienza
    S. Lotti
    G. Minervini
    L. Piro
    M. Biasotti
    L. Ferrari Barusso
    F. Gatti
    M. Rigano
    A. Volpe
    E. S. Battistelli
    Journal of Low Temperature Physics, 2020, 199 : 65 - 72
  • [5] The Cryogenic AntiCoincidence Detector for ATHENA X-IFU: a program overview
    Macculi, C.
    Argan, A.
    D'Andrea, M.
    Lotti, S.
    Laurenza, M.
    Piro, L.
    Biasotti, M.
    Corsini, D.
    Gatti, F.
    Torrioli, G.
    Fiorini, M.
    Molendi, S.
    Uslenghi, M.
    Mineo, T.
    Bulgarelli, A.
    Fioretti, V.
    Cavazzuti, E.
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
  • [6] The Cryogenic AntiCoincidence Detector for ATHENA X-IFU: The Project Status
    C. Macculi
    A. Argan
    D. Brienza
    M. D’Andrea
    S. Lotti
    G. Minervini
    L. Piro
    M. Biasotti
    L. Ferrari Barusso
    F. Gatti
    M. Rigano
    G. Torrioli
    M. Fiorini
    S. Molendi
    M. Uslenghi
    E. Cavazzuti
    A. Volpe
    Journal of Low Temperature Physics, 2020, 199 : 416 - 424
  • [7] The Cryogenic AntiCoincidence detector for ATHENA X-IFU: advancement in the project.
    Macculi, C.
    Argan, A.
    Brienza, D.
    D'Andrea, M.
    Lotfi, S.
    Minervini, G.
    Piro, L.
    Biasotti, M.
    Barusso, L. Ferrari
    Gatti, F.
    Rigano, M.
    Chiarello, F.
    Torrioli, G.
    Fiorini, M.
    Uslenghi, M.
    Cavazzuti, E.
    Puccetti, S.
    Volpe, A.
    SPACE TELESCOPES AND INSTRUMENTATION 2020: ULTRAVIOLET TO GAMMA RAY, 2021, 11444
  • [8] The end-to-end simulator of the ATHENA X-IFU Cryogenic AntiCoincidence detector (CryoAC)
    D'Andrea, M.
    Macculi, C.
    Lotti, S.
    Piro, L.
    Argan, A.
    Minervini, G.
    Torrioli, G.
    Chiarello, F.
    Barusso, L. Ferrari
    Gatti, F.
    Rigano, M.
    SPACE TELESCOPES AND INSTRUMENTATION 2024: ULTRAVIOLET TO GAMMA RAY, PT 1, 2024, 13093
  • [9] The Cryogenic AntiCoincidence Detector for ATHENA X-IFU: Improvement of the Test Setup Toward the Demonstration Model
    M. D’Andrea
    C. Macculi
    A. Argan
    S. Lotti
    G. Minervini
    L. Piro
    M. Biasotti
    D. Corsini
    F. Gatti
    G. Torrioli
    A. Volpe
    Journal of Low Temperature Physics, 2018, 193 : 958 - 967
  • [10] The new cryogenic silicon monolithic micro-bridged AntiCoincidence detector for the X-IFU of ATHENA
    Biasotti, M.
    Corsini, D.
    De Gerone, M.
    Gatti, F.
    Macculi, C.
    D'Andrea, M.
    Piro, L.
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905