The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific assessment of the observational capabilities in the hard X-ray band

被引:4
|
作者
D'Andrea, M. [1 ,2 ]
Lotti, S. [1 ]
Macculi, C. [1 ]
Piro, L. [1 ]
Argan, A. [1 ]
Gatti, F. [3 ]
机构
[1] INAF IAPS Roma, Via Fosso del Cavaliere 100, I-00133 Rome, Italy
[2] Univ Roma Tor Vergata, Dept Phys, Via Ric Sci 1, I-00133 Rome, Italy
[3] Univ Genoa, Dept Phys, Via Dodecaneso 33, I-16146 Genoa, Italy
关键词
X-rays: detectors; ATHENA; X-IFU; Anticoincidence detectors; ENERGY;
D O I
10.1007/s10686-017-9543-4
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028 towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a cryogenic spectrometer based on a large array of TES microcalorimeters, able to perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6 keV). The X-IFU sensitivity is highly degraded by the particle background expected in the L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the particle background level and enable the mission science goals, the instrument incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES based detector, placed < 1 mm below the main array. In this paper we report a scientific assessment of the CryoAC observational capabilities in the hard X-ray band (E > 10 keV). The aim of the study has been to understand if the present detector design can be improved in order to enlarge the X-IFU scientific capability on an energy band wider than the TES array. This is beyond the CryoAC baseline, being this instrument aimed to operate as anticoincidence particle detector and not conceived to perform X-ray observations.
引用
收藏
页码:359 / 370
页数:12
相关论文
共 50 条
  • [41] Radio Frequency shielding of thin aluminized plastic filters investigated for the ATHENA X-IFU detector
    Lo Cicero, Ugo
    Lo Cicero, Giuseppe
    Puccio, Elena
    Montinaro, Nicola
    Gulli, Daniele
    Todaro, Michela
    Calandra, Enrico
    Torma, Pekka P.
    Cuttaia, Francesco
    Villa, Fabrizio
    Bonura, Salvatore Ferruggia
    Lullo, Giuseppe
    Collura, Alfonso
    D'Anca, Fabio
    Sciortino, Luisa
    Varisco, Salvatore
    Jackson, Brian
    van Leeuwen, Bert-Joost
    Gloaguen, Emilie
    Barbera, M.
    SPACE TELESCOPES AND INSTRUMENTATION 2018: ULTRAVIOLET TO GAMMA RAY, 2018, 10699
  • [42] The Cryogenic Anti-Coincidence detector for ATHENA X-IFU: pulse analysis of the AC-S7 single pixel prototype
    D'Andrea, M.
    Argan, A.
    Lotti, S.
    Macculi, C.
    Piro, L.
    Biasotti, M.
    Corsini, D.
    Gatti, F.
    Torrioli, G.
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
  • [43] The Bionanoprobe: hard X-ray fluorescence nanoprobe with cryogenic capabilities
    Chen, S.
    Deng, J.
    Yuan, Y.
    Flachenecker, C.
    Mak, R.
    Hornberger, B.
    Jin, Q.
    Shu, D.
    Lai, B.
    Maser, J.
    Roehrig, C.
    Paunesku, T.
    Gleber, S. C.
    Vine, D. J.
    Finney, L.
    VonOsinski, J.
    Bolbat, M.
    Spink, I.
    Chen, Z.
    Steele, J.
    Trapp, D.
    Irwin, J.
    Feser, M.
    Snyder, E.
    Brister, K.
    Jacobsen, C.
    Woloschak, G.
    Vogt, S.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 66 - 75
  • [44] Thermal Simulations of Temperature Excursions on the Athena X-IFU Detector Wafer from Impacts by Cosmic Rays
    S. L. Stever
    P. Peille
    M. P. Bruijn
    A. Roussafi
    S. Lotti
    C. Macculi
    R. M. J. Janssen
    R. den Hartog
    Journal of Low Temperature Physics, 2020, 199 : 264 - 274
  • [45] Thermal Simulations of Temperature Excursions on the Athena X-IFU Detector Wafer from Impacts by Cosmic Rays
    Stever, S. L.
    Peille, P.
    Bruijn, M. P.
    Roussafi, A.
    Lotti, S.
    Macculi, C.
    Janssen, R. M. J.
    den Hartog, R.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2020, 199 (1-2) : 264 - 274
  • [46] Two-Stage SQUID Amplifier for the Frequency Multiplexed Readout of the X-IFU X-Ray Camera
    Kiviranta, Mikko
    Gronberg, Leif
    Puranen, Tuomas
    van der Kuur, Jan
    Beev, Nikolai
    Salonen, Jaakko
    Hazra, Dibyendu
    Korpela, Seppo
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2021, 31 (05)
  • [47] Cryogenic Hard X-ray Imaging Spectrometer for the International X-ray Observatory
    Leman, S. W.
    Figueroa-Feliciano, E.
    Kilbourne, C. A.
    Saab, T.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 703 - +
  • [48] Cryogenic radiometry in the hard x-ray range
    Gerlach, M.
    Krumrey, M.
    Cibik, L.
    Mueller, P.
    Rabus, H.
    Ulm, G.
    METROLOGIA, 2008, 45 (05) : 577 - 585
  • [49] Status report of the Hard X-ray detector
    Yamada, Shin'ya
    SUZAKU 2011: EXPLORING THE X-RAY UNIVERSE: SUZAKU AND BEYOND, 2012, 1427
  • [50] Scientific prospects for hard X-ray polarimetry
    Krawczynski, H.
    Ill, A. Garson
    Guo, Q.
    Baring, M. G.
    Ghosh, P.
    Beilicke, M.
    Lee, K.
    ASTROPARTICLE PHYSICS, 2011, 34 (07) : 550 - 567