Performance analysis and comparison of concentrated evacuated tube heat pipe solar collectors

被引:63
|
作者
Nkwetta, Dan Nchelatebe [1 ]
Smyth, Mervyn [2 ]
机构
[1] Tata Steel, Corus Colors, Sustainable Bldg Envelope Ctr, Deeside, Flint, Wales
[2] Univ Ulster, Fac Arts Design & Built Environm, Sch Built Environm, Ctr Sustainable Technol, Newtownabbey, North Ireland
关键词
Concentrated evacuated tube heat pipe; Single-sided coated absorber; Double-sided coated absorber and incident angle modifier; COOLING SYSTEM; DESIGN;
D O I
10.1016/j.apenergy.2012.02.059
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Two profiles of concentrated evacuated tube heat pipe solar collectors made of single-sided and double-sided absorber have been analyzed and compared under control conditions and results presented in this paper. These innovative concentrated evacuated tube heat pipe solar collectors were experimentally tested at a tilt angle of 60 degrees to the horizontal. Using in-door solar simulated experimental conditions temperature response, collection efficiency, heat loss coefficients and energy collection rates as well as the incident angle modifier (IAM) were recorded and compared at five different transverse angles (0-40 degrees) at 10 degrees increments. The use of concentrated single-sided and double-sided absorber evacuated tube heat pipe solar collectors is seen to be feasible for integrating solar thermal energy into buildings for heating demands. The concentrated double-sided absorber evacuated tube heat pipe proves better compared to the concentrated single-sided absorber evacuated tube heat pipe solar collector due to higher outlet temperature with greater temperature differential and improved thermal performance. The integration of this innovative system implies that the number of the evacuated tube heat pipe collectors needed to attain higher temperature is reduced. Furthermore, the size of reflectors and related reflector losses are reduced due to the truncated nature of the reflectors providing a low concentration ratio. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 50 条
  • [41] EXPERIMENTAL DAILY ENERGY PERFORMANCE OF FLAT PLATE AND EVACUATED TUBE SOLAR COLLECTORS
    Zambolin, Enrico
    Del Col, Davide
    Padovan, Andrea
    ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 853 - 862
  • [42] Research on thermal performance and flow resistance of evacuated tube solar air collectors
    Zeng, D. (zengdongqi6@163.com), 1600, Science Press (35):
  • [43] Validated TRNSYS model for forced circulation solar water heating systems with flat plate and heat pipe evacuated tube collectors
    Ayompe, L. M.
    Duffy, A.
    McCormack, S. J.
    Conlon, M.
    APPLIED THERMAL ENGINEERING, 2011, 31 (8-9) : 1536 - 1542
  • [44] The research on thermal and economic performance of solar desalination system with evacuated tube collectors
    Liu, Xiaohua
    Chen, Wenbo
    Shen, Shengqiang
    Gu, Ming
    Cao, Guojian
    DESALINATION AND WATER TREATMENT, 2013, 51 (19-21) : 3728 - 3734
  • [45] An experimental study of a heat pipe evacuated tube solar dryer with heat recovery system
    Daghigh, Roonak
    Shafieian, Abdellah
    RENEWABLE ENERGY, 2016, 96 : 872 - 880
  • [46] Thermal modeling of evacuated tube solar air collectors
    Paradis, Pierre-Luc
    Rousse, Daniel R.
    Halle, Stephane
    Lamarche, Louis
    Quesada, Guillermo
    SOLAR ENERGY, 2015, 115 : 708 - 721
  • [47] Experimental studies of thermal performance of an evacuated tube heat pipe solar collector in Polish climatic conditions
    Siuta-Olcha, Alicja
    Cholewa, Tomasz
    Dopieralska-Howoruszko, Kinga
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (12) : 14319 - 14328
  • [48] EVACUATED HEAT PIPE SOLAR COLLECTOR
    MAHDJURI, F
    ENERGY CONVERSION, 1979, 19 (02): : 85 - 90
  • [49] Progress and latest developments of evacuated tube solar collectors
    Sabiha, M. A.
    Saidur, R.
    Mekhilef, Saad
    Mahian, Omid
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 51 : 1038 - 1054
  • [50] Thermal performance of direct-flow coaxial evacuated-tube solar collectors with and without a heat shield
    Zhang, Xinyu
    You, Shijun
    Ge, Hongchuan
    Gao, Yan
    Xu, Wei
    Wang, Min
    He, Tao
    Zheng, Xuejing
    ENERGY CONVERSION AND MANAGEMENT, 2014, 84 : 80 - 87