摘要
Two profiles of concentrated evacuated tube heat pipe solar collectors made of single-sided and double-sided absorber have been analyzed and compared under control conditions and results presented in this paper. These innovative concentrated evacuated tube heat pipe solar collectors were experimentally tested at a tilt angle of 60 degrees to the horizontal. Using in-door solar simulated experimental conditions temperature response, collection efficiency, heat loss coefficients and energy collection rates as well as the incident angle modifier (IAM) were recorded and compared at five different transverse angles (0-40 degrees) at 10 degrees increments. The use of concentrated single-sided and double-sided absorber evacuated tube heat pipe solar collectors is seen to be feasible for integrating solar thermal energy into buildings for heating demands. The concentrated double-sided absorber evacuated tube heat pipe proves better compared to the concentrated single-sided absorber evacuated tube heat pipe solar collector due to higher outlet temperature with greater temperature differential and improved thermal performance. The integration of this innovative system implies that the number of the evacuated tube heat pipe collectors needed to attain higher temperature is reduced. Furthermore, the size of reflectors and related reflector losses are reduced due to the truncated nature of the reflectors providing a low concentration ratio. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 50 条
  • [31] Theoretical and experimental analysis of thermal performance of a solar water heating system with evacuated tube heat pipe collector
    Daghigh, Roonak
    Shafieian, Abdellah
    APPLIED THERMAL ENGINEERING, 2016, 103 : 1219 - 1227
  • [32] Latent and sensible heat thermal storage in a heat pipe-based evacuated tube solar dryer: A comparative performance analysis
    Mathew, Adarsh Abi
    Thangavel, Venugopal
    Mandhare, Neeta Amol
    Nukulwar, Masnaji R.
    JOURNAL OF ENERGY STORAGE, 2023, 57
  • [33] Performance comparison of air source heat pump coupling with solar evacuated tube water heater and that with micro heat pipe PV/T
    Li, Jinping
    Sun, Xiaohua
    Zhu, Junjie
    Karkon, Ehsan Gholamian
    Novakovic, Vojislav
    ENERGY, 2024, 300
  • [34] Performance investigation on a sun-tracking CPC heat pipe evacuated tube solar collector
    SUN Wei
    WANG Yinfeng
    CHEN Haijun
    MA Tingting
    ZHA Junjie
    YANG Moucun
    ZHU Yuezhao
    热力发电, 2013, 42 (11) : 26 - 30
  • [35] Thermal performance of an evacuated tube heat pipe solar water heating system in cold season
    Shafieian, Abdellah
    Khiadani, Mehdi
    Nosrati, Ataollah
    APPLIED THERMAL ENGINEERING, 2019, 149 : 644 - 657
  • [36] Evacuated tube solar heat pipe collector model and associated tests
    Jafarkazemi, Farzad
    Abdi, Hossein
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2012, 4 (02)
  • [37] Optical evaluation and analysis of an internal low-concentrated evacuated tube heat pipe solar collector for powering solar air-conditioning systems
    Nkwetta, Dan Nchelatebe
    Smyth, Mervyn
    Zacharopoulos, Aggelos
    Hyde, Trevor
    RENEWABLE ENERGY, 2012, 39 (01) : 65 - 70
  • [38] Performance Evaluation of Dual Purposes Solar Heating System Using Heat Pipe Evacuated Tube Solar Collector
    El-Ghetany, H. H.
    Hassan, S. A.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2021, 64 (07): : 3297 - 3303
  • [39] Thermal performance and parameter analysis of a U-pipe evacuated solar tube collector
    Gao, Y.
    Fan, R.
    Zhang, X. Y.
    An, Y. J.
    Wang, M. X.
    Gao, Y. K.
    Yu, Y.
    SOLAR ENERGY, 2014, 107 : 714 - 727
  • [40] Performance Analysis of Solar Evacuated Tube Collector
    Fang, Wenbo