99mTc-albumin can replace 125I-albumin to determine plasma volume repeatedly

被引:11
|
作者
Bonfils, Peter K. [1 ]
Damgaard, Morten [1 ]
Stokholm, Knud H. [1 ]
Nielsen, Steen L. [1 ]
机构
[1] Koege Hosp, Dept Clin Physiol & Nucl Med, DK-4600 Koege, Denmark
关键词
Plasma volume; blood volume; 99mTc-human serum albumin; 125I-human serum albumin; indicator dilution method; HUMAN-SERUM-ALBUMIN; BLOOD-VOLUME; HEART-FAILURE; CARDIAC-OUTPUT; TRANSFERRIN; YOUNG;
D O I
10.3109/00365513.2012.688856
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective. Plasma volume assessment may be of importance in several disorders. The purpose of the present study was to compare the reliability of plasma volume measurements by technetium-labeled human serum albumin (Tc-99m-HSA) with a simultaneously performed plasma volume determination with iodine-labeled human serum albumin (I-125-HSA). Materials and methods. In 15 healthy volunteers, simultaneous plasma volume measurements with Tc-99m-HSA and I-125-HSA were performed after 1/2 hour in the supine position. Blood samples were obtained 10, 15, 20, and 30 minutes after the injection for accurate retropolation from the plasma counts to time zero to correct for leakage of the isotopes from the circulation. Results. The mean difference (bias) between plasma volume measured with I-125-albumin and Tc-99m-albumin was 8 ml (0.1 ml/kg) with limits of agreement (bias +/- 1.96 SD) ranging from -181-196 ml (-2.3-2.5 ml/kg). The tracer disappearance rate was significantly higher with Tc-99m-albumin (-23.1-7.1%/h) than with I-125-albumin (-6.7 +/- 3.6%/h) (p < 0.001). Conclusion. This study demonstrates that Tc-99m-HSA can replace I-125-HSA for single measurements of plasma volume in healthy volunteers. It needs to be emphasized however, that repeated blood sampling for 1/2 hour after injection of the tracer is required to correct for the disappearance of Tc-99m and Tc-99m-HSA from the circulation.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 50 条
  • [31] 2 COMPARTMENT ANALYSIS OF PLASMA-VOLUME USING TC-99M ALBUMIN
    SELLERS, BB
    COVITZ, W
    EUBIG, C
    TRUMAN, AT
    SHELNUTT, R
    PEDIATRIC RESEARCH, 1979, 13 (04) : 351 - 351
  • [32] STUDY OF THE RELATIONSHIP BETWEEN PLASMA VOLUME AND TRANSCAPILLARY PROTEIN EXCHANGE USING I-131-LABELED ALBUMIN AND I-125-LABELED GLOBULIN
    WALKER, WG
    ROSS, RS
    HAMMOND, JDS
    CIRCULATION RESEARCH, 1960, 8 (05) : 1028 - 1040
  • [33] ERRORS IN PLASMA VOLUME MEASUREMENT FROM ADSORPTION LOSSES OF ALBUMIN-I-131
    REEVE, EB
    FRANKS, JJ
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1956, 93 (02): : 299 - 302
  • [34] The novel preparation of 99mTc(I)-labeled human serum albumin (HSA) nanoparticles as a SPECT imaging agent
    Chen, Wan-Jou
    Huang, Feng-Yun J.
    Chang, Hsiu-Yu
    Lee, Te-Wei
    Chang, Chien-Wen
    Lo, Jem-Mau
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (01) : 141 - 150
  • [35] The novel preparation of 99mTc(I)-labeled human serum albumin (HSA) nanoparticles as a SPECT imaging agent
    Wan-Jou Chen
    Feng-Yun J. Huang
    Hsiu-Yu Chang
    Te-Wei Lee
    Chien-Wen Chang
    Jem-Mau Lo
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 141 - 150
  • [36] Can 99mTc-ciprofloxacin (CIP) imaging differentiate infection from sterile inflammation?:: Comparison with 99mTc-human IgG (HIG) and 99mTc-human serum albumin (HSA) in rat model.
    Ryu, JS
    Shin, JW
    Oh, SJ
    Cheon, JH
    Moon, DH
    Lee, HK
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 322P - +
  • [37] Tc-99M-albumin can be used as an intraperitoneal (IP) volume marker in peritoneal dialysis (PD).
    Wang, T
    Werynski, A
    Wankowicz, Z
    Waniewski, J
    Heimburger, O
    Lindholm, B
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 : A1348 - A1348
  • [38] Tumor quadrant and depth independent subareolar injection of 99mTc-albumin colloid (AC) and blue dye (BD) in detection of sentinel lymph node/s (SLN) in carcinoma breast.
    Gambhir, S
    Azad, M
    Barlow, R
    Morris, G
    Al-Yasi, AR
    Carpenter, R
    Britton, KE
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 116P - 117P
  • [39] Intravascular circulation and distribution of human 51Cr-DBBF stroma-free hemoglobin, 51Cr-plasma, 51Cr-saline, 59Fe-plasma, and 125I-albumin in the mouse
    Valeri, CR
    Ichikura, T
    Pivacek, LE
    Giorgio, A
    Prusty, S
    Dittmer, J
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY, 2000, 28 (06): : 451 - 475
  • [40] EFFECT OF VASOACTIVE DRUGS ON DISTRIBUTION VOLUME FOR I-125 ALBUMIN IN RABBIT COMMON CAROTID-ARTERY
    BALDWIN, AL
    LEVER, MJ
    CARO, CG
    FEDERATION PROCEEDINGS, 1982, 41 (04) : 1234 - 1234