99mTc-albumin can replace 125I-albumin to determine plasma volume repeatedly

被引:11
|
作者
Bonfils, Peter K. [1 ]
Damgaard, Morten [1 ]
Stokholm, Knud H. [1 ]
Nielsen, Steen L. [1 ]
机构
[1] Koege Hosp, Dept Clin Physiol & Nucl Med, DK-4600 Koege, Denmark
关键词
Plasma volume; blood volume; 99mTc-human serum albumin; 125I-human serum albumin; indicator dilution method; HUMAN-SERUM-ALBUMIN; BLOOD-VOLUME; HEART-FAILURE; CARDIAC-OUTPUT; TRANSFERRIN; YOUNG;
D O I
10.3109/00365513.2012.688856
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective. Plasma volume assessment may be of importance in several disorders. The purpose of the present study was to compare the reliability of plasma volume measurements by technetium-labeled human serum albumin (Tc-99m-HSA) with a simultaneously performed plasma volume determination with iodine-labeled human serum albumin (I-125-HSA). Materials and methods. In 15 healthy volunteers, simultaneous plasma volume measurements with Tc-99m-HSA and I-125-HSA were performed after 1/2 hour in the supine position. Blood samples were obtained 10, 15, 20, and 30 minutes after the injection for accurate retropolation from the plasma counts to time zero to correct for leakage of the isotopes from the circulation. Results. The mean difference (bias) between plasma volume measured with I-125-albumin and Tc-99m-albumin was 8 ml (0.1 ml/kg) with limits of agreement (bias +/- 1.96 SD) ranging from -181-196 ml (-2.3-2.5 ml/kg). The tracer disappearance rate was significantly higher with Tc-99m-albumin (-23.1-7.1%/h) than with I-125-albumin (-6.7 +/- 3.6%/h) (p < 0.001). Conclusion. This study demonstrates that Tc-99m-HSA can replace I-125-HSA for single measurements of plasma volume in healthy volunteers. It needs to be emphasized however, that repeated blood sampling for 1/2 hour after injection of the tracer is required to correct for the disappearance of Tc-99m and Tc-99m-HSA from the circulation.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 50 条
  • [21] Isotopic blood volume:: Interest of 125I-human serum albumin in determination of plasma volume.
    Blanc-Beguin, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S336 - S336
  • [22] INITIAL PLASMA DISAPPEARANCE AND DISTRIBUTION VOLUME OF [I-131]ALBUMIN AND [I-125]FIBRINOGEN IN MAN
    BENTHANSEN, L
    ACTA PHYSIOLOGICA SCANDINAVICA, 1989, 136 (03): : 455 - 461
  • [23] Nasal Mucociliary Clearance of 99mTc-albumin colloid: a quantitative test of nasal ciliary function and potential outcome parameter in primary ciliary dyskinesia
    Marthin, June Kehlet
    Nielsen, Kim Gjerum
    Mortensen, Jann
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [24] Could the quality and the quantitative amount of 99mTc-albumin colloidal particles injected could affect the lymph node detection failure in breast cancer patients?
    Marazzini, M.
    Cidda, C.
    Graziani, T.
    Migliari, S.
    Sammartano, A.
    Lazzara, C.
    Ruffini, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S246 - S246
  • [25] STUDIES ON TRANSMISSION OF I-125 IGG AND I-125 ALBUMIN FROM SERUM TO SEMINAL PLASMA IN BOARS
    MARTINSSON, K
    EINARSSON, S
    GUSTAFSSON, B
    ACTA VETERINARIA SCANDINAVICA, 1973, 14 (02) : 272 - 277
  • [26] A new method for plasma volume measurements with unlabeled dextran-70 instead of 125I-labeled albumin as an indicator
    van Kreel, BK
    van Beek, E
    Spaanderman, MEA
    Peeters, LLH
    CLINICA CHIMICA ACTA, 1998, 275 (01) : 71 - 80
  • [27] LIMITATIONS OF MEASURING BLOOD-VOLUME WITH IODINATED I-125 SERUM-ALBUMIN
    VALERI, CR
    COOPER, AG
    PIVACEK, LE
    ARCHIVES OF INTERNAL MEDICINE, 1973, 132 (04) : 534 - 538
  • [28] COMPARISON OF 51CR-RBCS AND 125I-ALBUMIN AS MARKERS TO ESTIMATE LYMPH-DRAINAGE OF THE PERITONEAL-CAVITY IN CONSCIOUS SHEEP
    YUAN, Z
    RODELA, H
    HAY, JB
    OREOPOULOS, D
    JOHNSTON, MG
    FASEB JOURNAL, 1993, 7 (04): : A560 - A560
  • [29] METHOD FOR MEASURING NORMAL BLOOD VOLUME OF RAT USING [I-125] LABELLED ALBUMIN
    BROOKS, S
    AUSTRALIAN JOURNAL OF EXPERIMENTAL BIOLOGY AND MEDICAL SCIENCE, 1971, 49 (APR): : 241 - &
  • [30] DISTRIBUTION AND DEGRADATION OF I125 ALBUMIN MICROSPHERES AND TECHNETIUM-99M SULFUR COLLOID
    BERNARD, NG
    SHAW, SM
    KESSLER, WV
    LANDOLT, RR
    PECK, GE
    DOCKERTY, GH
    CANADIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 1980, 15 (02): : 30 - 34