99mTc-albumin can replace 125I-albumin to determine plasma volume repeatedly

被引:11
|
作者
Bonfils, Peter K. [1 ]
Damgaard, Morten [1 ]
Stokholm, Knud H. [1 ]
Nielsen, Steen L. [1 ]
机构
[1] Koege Hosp, Dept Clin Physiol & Nucl Med, DK-4600 Koege, Denmark
关键词
Plasma volume; blood volume; 99mTc-human serum albumin; 125I-human serum albumin; indicator dilution method; HUMAN-SERUM-ALBUMIN; BLOOD-VOLUME; HEART-FAILURE; CARDIAC-OUTPUT; TRANSFERRIN; YOUNG;
D O I
10.3109/00365513.2012.688856
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective. Plasma volume assessment may be of importance in several disorders. The purpose of the present study was to compare the reliability of plasma volume measurements by technetium-labeled human serum albumin (Tc-99m-HSA) with a simultaneously performed plasma volume determination with iodine-labeled human serum albumin (I-125-HSA). Materials and methods. In 15 healthy volunteers, simultaneous plasma volume measurements with Tc-99m-HSA and I-125-HSA were performed after 1/2 hour in the supine position. Blood samples were obtained 10, 15, 20, and 30 minutes after the injection for accurate retropolation from the plasma counts to time zero to correct for leakage of the isotopes from the circulation. Results. The mean difference (bias) between plasma volume measured with I-125-albumin and Tc-99m-albumin was 8 ml (0.1 ml/kg) with limits of agreement (bias +/- 1.96 SD) ranging from -181-196 ml (-2.3-2.5 ml/kg). The tracer disappearance rate was significantly higher with Tc-99m-albumin (-23.1-7.1%/h) than with I-125-albumin (-6.7 +/- 3.6%/h) (p < 0.001). Conclusion. This study demonstrates that Tc-99m-HSA can replace I-125-HSA for single measurements of plasma volume in healthy volunteers. It needs to be emphasized however, that repeated blood sampling for 1/2 hour after injection of the tracer is required to correct for the disappearance of Tc-99m and Tc-99m-HSA from the circulation.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 50 条
  • [1] 99mTc-labelled human serum albumin cannot replace 125I-labelled human serum albumin to determine plasma volume in patients with liver disease
    Henriksen, Ulrik Luetken
    Henriksen, Jens H.
    Bendtsen, Flemming
    Moller, Soren
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2013, 33 (03) : 211 - 217
  • [2] A KIT FOR RAPID PREPARATION OF STERILE 99MTC-ALBUMIN
    COOPER, JF
    STERN, HS
    JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (06) : 328 - &
  • [3] METABOLIC BEHAVIOR AND RADIATION DOSIMETRY OF 99MTC-ALBUMIN IN PREGNANCY
    HERBERT, RJT
    HIBBARD, BM
    SHEPPARD, MA
    JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (05) : 224 - &
  • [4] Presacral Myelolipoma The Usefulness of a 99mTc-Albumin Nanocolloid Scintigraphy
    Guillaume, Laurent
    Vander Borght, Thierry
    Bertrand, Claude
    Dupont, Michael
    Krug, Bruno
    CLINICAL NUCLEAR MEDICINE, 2021, 46 (01) : 38 - 39
  • [5] IMPROVED LUNG SCANS USING 99MTC-ALBUMIN MICROSPHERES
    RHODES, BA
    WAGNER, HN
    JOURNAL OF NUCLEAR MEDICINE, 1969, 10 (06) : 432 - &
  • [6] 99mTc-albumin nanocolloid joint scintigraphy in RA patients in clinical remission
    Tishler, Moshe
    Levy, Ofer
    Volkov, Olga
    Lyssy, Oleg
    Golan, Haim
    ARTHRITIS AND RHEUMATISM, 2008, 58 (09): : S768 - S769
  • [7] Bronchoscintigraphy and pulmonary clearance of 99mTc-albumin colloid in the study of mucociliary clearance
    Mortensen, J
    DANISH MEDICAL BULLETIN, 1998, 45 (02) : 195 - 209
  • [8] Anaphylaxis to Poloxamer 238 during a lung scintigraphy with 99mTc-albumin macroaggregates injection
    Morisset, M.
    Kuehn, A.
    Scheuermann, T.
    Larosche, I
    Hougardy, N.
    Morel-Codreanu, F.
    Ollert, M.
    Hilger, C.
    ALLERGY, 2016, 71 : 349 - 350
  • [9] Evaluation of two chromatographic methods for radiochemical quality control of 99mTc-albumin nanocolloid and 99mTc-colloidal sulphide
    Urbano, N
    Modoni, S
    Martino, G
    Dicembrino, F
    Palladino, G
    Frusciante, V
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1113 - 1113
  • [10] Transcapillary Escape Rate of 125I-Albumin in Relation to Timing of Blood Sampling
    Chahid, Y.
    Rorije, N. M. G.
    Vogt, L.
    Verberne, H. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S655 - S656