Three-Dimensional Digital Stereophotogrammetry: A Reliable and Valid Technique for Measuring Scar Surface Area

被引:26
|
作者
Stekelenburg, Carlijn M.
van der Wal, Martijn B. A.
Knol, Dirk L.
de Vet, Henrica C. W.
van Zuijlen, Paul P. M.
机构
[1] Assoc Dutch Burn Ctr, Beverwijk, Netherlands
[2] Red Cross Hosp, Dept Plast & Reconstruct Surg, Beverwijk, Netherlands
[3] Red Cross Hosp, Burn Ctr, Beverwijk, Netherlands
[4] Vrije Univ Amsterdam, MOVE Res Inst, Amsterdam, Netherlands
[5] Vrije Univ Amsterdam, Med Center, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[6] Vrije Univ Amsterdam, Med Center, EMGO Inst Hlth & Care Res, Amsterdam, Netherlands
关键词
ANTHROPOMETRIC PRECISION; ACCURACY; PHOTOGRAMMETRY; RELIABILITY; PATIENT; GENEX; TOOLS;
D O I
10.1097/PRS.0b013e318290f675
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The surface area of scars is an important outcome parameter in scar assessment. It is often used to quantify the extent of scar features, such as pigmentation disturbances, hypertrophy, and contracture. Currently available techniques for measuring the surface area are known to be cumbersome or do not meet the basic clinimetric criteria (i.e., reliability and validity). Three-dimensional stereophotogrammetry is a technique that may improve the quality of surface area measurements. The aim of this study was to investigate the reliability and validity of three-dimensional stereophotogrammetry for measuring scar surface area. Methods: In a cross-sectional study, two independent clinicians photographed and measured 50 scar areas of 32 patients using a handheld stereographic camera, to assess reliability. Subsequently, using planimetry, the scar surface was traced on a transparent sheet (considered the accepted standard) to assess validity. Results: Three-dimensional stereophotogrammetry showed good reliability, with an intraclass correlation coefficient of 0.99 and a coefficient of variation of 6.8 percent. To visualize the differences between the two observers, data were plotted and the limits of agreement were calculated at 0 +/- 0.19 x mean surface area. Also, excellent validity was found, with a concordance correlation coefficient of 0.99. Conclusion: This study showed that three-dimensional stereophotogrammetry is a reliable and valid tool for research purposes in the field of scar surface area measurements.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 50 条
  • [41] Digital holographic interferometry for measuring the absorbed three-dimensional dose distribution
    Mohammad Reza Rashidian Vaziri
    Amir Mohammad Beigzadeh
    Farhood Ziaie
    Mehrdad Yarahmadi
    The European Physical Journal Plus, 135
  • [42] Digital holographic microscope for measuring three-dimensional particle distributions and motions
    Sheng, Jian
    Malkiel, Edwin
    Katz, Joseph
    APPLIED OPTICS, 2006, 45 (16) : 3893 - 3901
  • [43] Digital holographic interferometry for measuring the absorbed three-dimensional dose distribution
    Vaziri, Mohammad Reza Rashidian
    Beigzadeh, Amir Mohammad
    Ziaie, Farhood
    Yarahmadi, Mehrdad
    EUROPEAN PHYSICAL JOURNAL PLUS, 2020, 135 (06):
  • [44] DERMATOLOGIC SCAR ASSESSMENT WITH STEREOSCOPIC IMAGING AND DIGITAL THREE-DIMENSIONAL MODELS: A VALIDATION STUDY
    Hendel, Kristoffer
    Ortner, Vinzent
    Fuchs, Christine
    Eckhouse, Vardit
    LASERS IN SURGERY AND MEDICINE, 2021, 53 : S25 - S25
  • [45] Is portable three-dimensional ultrasound a valid technique for measurement of postpartum urinary bladder volume?
    Nusee, Zalina
    Ibrahim, Norliza
    Rus, Razman Mohd
    Ismail, Hamizah
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2014, 53 (01): : 12 - 16
  • [46] Feature matching for automated and reliable initialization in three-dimensional digital image correlation
    Zhou, Yihao
    Chen, Yan Qiu
    OPTICS AND LASERS IN ENGINEERING, 2013, 51 (03) : 213 - 223
  • [47] Dermatologic Scar Assessment With Stereoscopic Imaging and Digital Three-Dimensional Models: A Validation Study
    Hendel, Kristoffer
    Ortner, Vinzent K.
    Fuchs, Christine S. K.
    Eckhouse, Vardit
    Haedersdal, Merete
    LASERS IN SURGERY AND MEDICINE, 2021, 53 (08) : 1043 - 1049
  • [48] Three-dimensional localization of cochlear implant electrodes using epipolar stereophotogrammetry
    Yoo, SK
    Wang, G
    Collison, F
    Rubinstein, JT
    Vannier, MW
    Kim, FJ
    Kim, NH
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (05) : 838 - 846
  • [49] Reproducibility and reliability of three-dimensional soft tissue landmark identification using three- dimensional stereophotogrammetry
    Baysal, Asli
    Sahan, Ahmet Oguz
    Ozturk, Mehmet Ali
    Uysal, Tancan
    ANGLE ORTHODONTIST, 2016, 86 (06) : 1004 - 1009
  • [50] A novel technique for measuring flying object's three-dimensional pose
    Wang, F.
    Guan, A. H.
    Wang, W.
    Liang, Y. T.
    Yin, H.
    Zhou, R. K.
    2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 2, 2008, : 803 - 807