Background: The surface area of scars is an important outcome parameter in scar assessment. It is often used to quantify the extent of scar features, such as pigmentation disturbances, hypertrophy, and contracture. Currently available techniques for measuring the surface area are known to be cumbersome or do not meet the basic clinimetric criteria (i.e., reliability and validity). Three-dimensional stereophotogrammetry is a technique that may improve the quality of surface area measurements. The aim of this study was to investigate the reliability and validity of three-dimensional stereophotogrammetry for measuring scar surface area. Methods: In a cross-sectional study, two independent clinicians photographed and measured 50 scar areas of 32 patients using a handheld stereographic camera, to assess reliability. Subsequently, using planimetry, the scar surface was traced on a transparent sheet (considered the accepted standard) to assess validity. Results: Three-dimensional stereophotogrammetry showed good reliability, with an intraclass correlation coefficient of 0.99 and a coefficient of variation of 6.8 percent. To visualize the differences between the two observers, data were plotted and the limits of agreement were calculated at 0 +/- 0.19 x mean surface area. Also, excellent validity was found, with a concordance correlation coefficient of 0.99. Conclusion: This study showed that three-dimensional stereophotogrammetry is a reliable and valid tool for research purposes in the field of scar surface area measurements.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 50 条
  • [31] Proximal Isovelocity Surface Area: The Three-Dimensional "Correction"
    Skubas, Nikolaos J.
    Lang, Roberto M.
    ANESTHESIA AND ANALGESIA, 2015, 120 (03): : 513 - 514
  • [32] Surface area overestimation within three-dimensional digital images and its consequence for skeletal dosimetry
    Rajon, DA
    Patton, PW
    Shah, AP
    Watchman, CJ
    Bolch, WE
    MEDICAL PHYSICS, 2002, 29 (05) : 682 - 693
  • [33] Detection of surface strain by three-dimensional digital holography
    De la Torre-Ibarra, M
    Mendoza-Santoyo, F
    Pérez-López, C
    Saucedo, T
    APPLIED OPTICS, 2005, 44 (01) : 27 - 31
  • [34] A modified moire technique for three-dimensional surface topography
    D'Acquisto, L
    Fratini, L
    Siddiolo, AM
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (04) : 613 - 622
  • [35] Estimation of surface area and surface area measure of three-dimensional sets from digitizations
    Ziegel, Johanna
    Kiderlen, Markus
    IMAGE AND VISION COMPUTING, 2010, 28 (01) : 64 - 77
  • [36] Error evaluation technique for three-dimensional digital image correlation
    Hu, Zhenxing
    Xie, Huimin
    Lu, Jian
    Wang, Huaixi
    Zhu, Jianguo
    APPLIED OPTICS, 2011, 50 (33) : 6239 - 6247
  • [37] Three-dimensional shape measuring for specular surface based on phase measuring deflectometry
    Yuan T.
    Zhang F.
    Tao X.
    Fu J.
    Guangxue Xuebao/Acta Optica Sinica, 2016, 36 (02):
  • [38] Rapid three-dimensional measuring system for facial surface structure
    Yamada, T
    Sugahara, T
    Mori, Y
    Sakuda, M
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 102 (06) : 2108 - 2113
  • [39] Measuring three-dimensional deformation with surface-imaging ORVIS
    Cooper, M. A.
    Specht, P. E.
    Trott, W. M.
    18TH APS-SCCM AND 24TH AIRAPT, PTS 1-19, 2014, 500
  • [40] Measuring of a three-dimensional surface by use of a spatial distance computation
    Chen, YS
    Chen, BT
    APPLIED OPTICS, 2003, 42 (11) : 1958 - 1972