Three-Dimensional Digital Stereophotogrammetry: A Reliable and Valid Technique for Measuring Scar Surface Area

被引:26
|
作者
Stekelenburg, Carlijn M.
van der Wal, Martijn B. A.
Knol, Dirk L.
de Vet, Henrica C. W.
van Zuijlen, Paul P. M.
机构
[1] Assoc Dutch Burn Ctr, Beverwijk, Netherlands
[2] Red Cross Hosp, Dept Plast & Reconstruct Surg, Beverwijk, Netherlands
[3] Red Cross Hosp, Burn Ctr, Beverwijk, Netherlands
[4] Vrije Univ Amsterdam, MOVE Res Inst, Amsterdam, Netherlands
[5] Vrije Univ Amsterdam, Med Center, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[6] Vrije Univ Amsterdam, Med Center, EMGO Inst Hlth & Care Res, Amsterdam, Netherlands
关键词
ANTHROPOMETRIC PRECISION; ACCURACY; PHOTOGRAMMETRY; RELIABILITY; PATIENT; GENEX; TOOLS;
D O I
10.1097/PRS.0b013e318290f675
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The surface area of scars is an important outcome parameter in scar assessment. It is often used to quantify the extent of scar features, such as pigmentation disturbances, hypertrophy, and contracture. Currently available techniques for measuring the surface area are known to be cumbersome or do not meet the basic clinimetric criteria (i.e., reliability and validity). Three-dimensional stereophotogrammetry is a technique that may improve the quality of surface area measurements. The aim of this study was to investigate the reliability and validity of three-dimensional stereophotogrammetry for measuring scar surface area. Methods: In a cross-sectional study, two independent clinicians photographed and measured 50 scar areas of 32 patients using a handheld stereographic camera, to assess reliability. Subsequently, using planimetry, the scar surface was traced on a transparent sheet (considered the accepted standard) to assess validity. Results: Three-dimensional stereophotogrammetry showed good reliability, with an intraclass correlation coefficient of 0.99 and a coefficient of variation of 6.8 percent. To visualize the differences between the two observers, data were plotted and the limits of agreement were calculated at 0 +/- 0.19 x mean surface area. Also, excellent validity was found, with a concordance correlation coefficient of 0.99. Conclusion: This study showed that three-dimensional stereophotogrammetry is a reliable and valid tool for research purposes in the field of scar surface area measurements.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 50 条
  • [1] Three-dimensional imaging: a novel, valid, and reliable technique for measuring wound surface area
    Rashaan, Z. M.
    Stekelenburg, C. M.
    van der Wal, M. B. A.
    Euser, A. M.
    Hagendoorn, B. J. M.
    van Zuijlen, P. P. M.
    Breederveld, R. S.
    SKIN RESEARCH AND TECHNOLOGY, 2016, 22 (04) : 443 - 450
  • [2] Stereophotogrammetry - A three-dimensional posture measuring tool
    Mechan, JE
    Porter, ML
    CONTEMPORARY ERGONOMICS 1997, 1997, : 455 - 460
  • [3] Three-dimensional imaging is a novel and reliable technique to measure total body surface area
    Rashaan, Z. M.
    Euser, A. M.
    van Zuijlen, P. P. M.
    Breederveld, R. S.
    BURNS, 2018, 44 (04) : 816 - 822
  • [4] In a clinimetric analysis, 3D stereophotogrammetry was found to be reliable and valid for measuring scar volume in clinical research
    Stekelenburg, Carlijn M.
    Jaspers, Marielle E. H.
    Niessen, Frank B.
    Knol, Dirk L.
    van der Wal, Martijn B. A.
    de Vet, Henrica C. W.
    van Zuijlen, Paul P. M.
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 2015, 68 (07) : 782 - 787
  • [5] Reliability of periocular anthropometry using three-dimensional digital stereophotogrammetry
    Yongwei Guo
    Alexander C. Rokohl
    Friederike Schaub
    Xiaoyi Hou
    Jinhua Liu
    Yue Ruan
    Renbing Jia
    Konrad R. Koch
    Ludwig M. Heindl
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2019, 257 : 2517 - 2531
  • [6] Measurement of three-dimensional deformation vectors with digital holography and stereophotogrammetry
    Schwede, Robert
    Babovsky, Holger
    Kiessling, Armin
    Kowarschik, Richard
    OPTICS LETTERS, 2012, 37 (11) : 1943 - 1945
  • [7] Reliability of periocular anthropometry using three-dimensional digital stereophotogrammetry
    Guo, Yongwei
    Rokohl, Alexander C.
    Schaub, Friederike
    Hou, Xiaoyi
    Liu, Jinhua
    Ruan, Yue
    Jia, Renbing
    Koch, Konrad R.
    Heindl, Ludwig M.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 257 (11) : 2517 - 2531
  • [8] Picture Perfect? Reliability of Craniofacial Anthropometry Using Three-Dimensional Digital Stereophotogrammetry
    Heike, Carrie L.
    Cunningham, Michael L.
    Hing, Anne V.
    Starr, Erik Stuhaug Jacqueline R.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 124 (04) : 1261 - 1272
  • [9] Three-dimensional digital imaging is as accurate and reliable to measure leg ulcer area as transparent tracing with digital planimetry
    Chaby, Guillaume
    Lok, Catherine
    Thirion, Jean Philippe
    Lucien, Arnaud
    Senet, Patricia
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2017, 5 (06) : 837 - 843
  • [10] Protocol Establishment and Reliability Verification of Three-Dimensional Digital Stereophotogrammetry in Lower Eyelid Anthropometry
    Chi, Yarong
    Yang, Yuyan
    Jin, Lin
    Chong, Yuming
    Huang, Jiuzuo
    Yu, Nanze
    Long, Xiao
    AESTHETIC PLASTIC SURGERY, 2024, 48 (07) : 1276 - 1287