Adsorptive stripping voltammetric determination of Tetracycline in pharmaceutical capsule formulation using Poly(Malachite green) modified glassy carbon electrode

被引:14
|
作者
Turbale, Mahilet [1 ]
Moges, Amsalu [2 ]
Dawit, Mulugeta [3 ]
Amare, Meareg [4 ]
机构
[1] Samara Univ, Semera, Ethiopia
[2] Debre Markos Univ, Debre Marqos, Ethiopia
[3] Debre Tabor Univ, Debra Tabor, Ethiopia
[4] Bahir Dar Univ, Bahir Dar, Ethiopia
关键词
Ampicillin; Electrocatalytic; Interference; Modified electrode; poly(malachite green); Spike recovery; Tetracycline; FLOW-INJECTION; GRAPHENE OXIDE; RESIDUES; ANTIBIOTICS; FILM; NANOPARTICLES; VALIDATION; SAMPLES; MILK;
D O I
10.1016/j.heliyon.2020.e05782
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A selective and sensitive electrochemical method based on glassy carbon electrode modified with poly(malachite green) was developed for determination of tetracycline in pharmaceutical capsule formulation. Cyclic voltammetry and electrochemical impedance spectroscopy using [Fe(CN)(6)](3-/4-) as a probe were used to characterize the potentiodynamiclly deposited poly(malachite green) on the surface of glassy carbon electrode. In contrast to the unmodified glassy carbon electrode, the fabricated poly(malachite green) modified glassy carbon electrode showed catalytic property towards two steps irreversible oxidation of tetracycline. Better correlation of the oxidative peak current with the scan rate than with the square root of scan rate supported by slope of 0.60 for log(current) versus log(scan rate) indicated that the oxidation reaction of tetracycline at the modified electrode was predominantly controlled by electron exchange step at the solution polymer interface. Under optimized solution pH, and accumulation parameters, the square wave adsorptive anodic striping peak current response of the modified electrode showed linear dependence on concentration of tetracycline in the range 5-100 mu M with determination coefficient, method detection limit, and quantification limit of 0.99588, 1.6 mu M, and 5.3 mu M, respectively. The tetracycline content of a capsule sample claimed to have 250 mg/capsule was found to be 250.53 mg/capsule with 0.21% deviation. Excellent spike recovery result of 99.80%, and 98.49-99.78% recovery of tetracycline in capsule sample in the presence of 50-200% of UA, AA, and ampicillin validated the applicability of the method for determination of tetracycline in real samples with complex matrix like capsule formulations.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Voltammetric determination of catechol and hydroquinone at poly (murexide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Rani, T. Shobha
    Ganesh, P. S.
    Raj, Y. Paul
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 746 - 752
  • [42] Voltammetric determination of bisoprolol on a glassy carbon electrode modified by poly(arylene phthalide)
    Zil'berg, R. A.
    Yarkaeva, Yu. A.
    Sidel'nikov, A. V.
    Maistrenko, V. N.
    Kraikin, V. A.
    Gileva, N. G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (09) : 926 - 931
  • [43] Electrochemical determination of malachite green using a multi-wall carbon nanotube modified glassy carbon electrode
    Yi, Hongchao
    Qu, Wanyun
    Huang, Wensheng
    MICROCHIMICA ACTA, 2008, 160 (1-2) : 291 - 296
  • [44] Voltammetric determination of bisoprolol on a glassy carbon electrode modified by poly(arylene phthalide)
    R. A. Zil’berg
    Yu. A. Yarkaeva
    A. V. Sidel’nikov
    V. N. Maistrenko
    V. A. Kraikin
    N. G. Gileva
    Journal of Analytical Chemistry, 2016, 71 : 926 - 931
  • [45] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511
  • [46] Determination of oleuropein using multiwalled carbon nanotube modified glassy carbon electrode by adsorptive stripping square wave voltammetry
    Cittan, Mustafa
    Kocak, Suleyman
    Celik, Ali
    Dost, Kenan
    TALANTA, 2016, 159 : 148 - 154
  • [47] Electrochemical determination of malachite green using a multi-wall carbon nanotube modified glassy carbon electrode
    Hongchao Yi
    Wanyun Qu
    Wensheng Huang
    Microchimica Acta, 2008, 160 : 291 - 296
  • [48] Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
    Khodadadian, Mehdi
    Jalili, Ronak
    Bahrami, Mohammad Taher
    Bahrami, Gholamreza
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2017, 16 (04): : 1312 - 1319
  • [49] Adsorptive stripping voltammetric determination of dicyclomine hydrochloride at a glassy carbon electrode modified with silver decorated Fe3O4 nanocubes in pharmaceutical and biological samples
    Rawool, Chaitali R.
    Rajpurohit, Anuja S.
    Punde, Ninad S.
    Srivastava, Ashwini K.
    ANALYTICAL METHODS, 2018, 10 (12) : 1441 - 1451
  • [50] Differential pulse adsorptive stripping voltammetric determination of chlorpyrifos at a sepiolite modified carbon paste electrode
    Sirisha, Kamireddy
    Mallipattu, Sreedhar
    Reddy, Sreenivasula Reddy Jayarama
    ANALYTICAL LETTERS, 2007, 40 (10) : 1939 - 1950