FAILURE RESISTANT DATA CENTER COOLING CONTROL THROUGH MODEL-BASED THERMAL ZONE MAPPING

被引:0
|
作者
Zhou, Rongliang [1 ]
Wang, Zhikui [1 ]
Bash, Cullen E. [1 ]
Cader, Tahir
McReynolds, Alan [1 ]
机构
[1] Hewlett Packard Corp, Sustainable Ecosyst Res Grp, HP Labs, Palo Alto, CA 94304 USA
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Due to the tremendous cooling costs, data center cooling efficiency improvement has been actively pursued for years. In addition to cooling efficiency, the reliability of the. cooling system is also essential for guaranteed uptime. In traditional data center cooling system design with N+1 or higher redundancy, all the computer room air conditioning (CRAG) units are either constantly online or cycled according to a predefined schedule. Both cooling system configurations, however have their respective drawbacks. Data centers are usually over provisioned when all CRAG units are online all the time, and hence the cooling efficiency is low On the other hand, although cooling efficiency can be improved by cycling CRAG units and turning off the backups, it is difficult to schedule the cycling such that sufficient cooling provisioning is guaranteed and gross over provisioning is avoided. In this paper, we aim to maintain the data center cooling redundancy while achieving high cooling efficiency. Using model-based thermal zone mapping, we first partition data centers to achieve the desired level of cooling influence redundancy. We then design a distributed controller for each of the CRAC units to regulate the. thermal status within its zone of influence. The distributed controllers coordinate with each other to achieve the desired data center thermal status using the least cooling power When CRAG units or their associated controllers fail, racks in the affected thermal zones are still within the control "radius" of other decentralized cooling controllers through predefined thermal zone overlap, and hence their thermal status is properly managed by the active CRAG units and controllers. Using this failure resistant data center cooling control approach, both cooling efficiency and robustness are achieved simultaneously. A higher flexibility in cooling system maintenance is also expected, since the distributed control system can automatically adapt to the new cooling facility configuration incurred by maintenance.
引用
收藏
页码:751 / 757
页数:7
相关论文
共 50 条
  • [31] Successive Linearization in Model-based Control for Thermal Management Systems
    El Chamie, Mahmoud
    Lin, Fu
    2018 ANNUAL AMERICAN CONTROL CONFERENCE (ACC), 2018, : 1540 - 1545
  • [32] A sparse matrix model-based optical proximity correction algorithm with model-based mapping between segments and control sites
    Bin Lin
    Xiao-lang Yan
    Zheng Shi
    Yi-wei Yang
    Journal of Zhejiang University SCIENCE C, 2011, 12 : 436 - 442
  • [33] Hidden Markov Model-based Load Balancing in Data Center Networks
    He, Binjie
    Zhang, Dong
    Zhao, Chang
    COMPUTER JOURNAL, 2020, 63 (10): : 1449 - 1462
  • [34] A sparse matrix model-based optical proximity correction algorithm with model-based mapping between segments and control sites
    Bin LINXiaolang YANZheng SHIYiwei YANG Institute of VLSI DesignZhejiang UniversityHangzhou China
    Journal of Zhejiang University-Science C(Computers & Electronics), 2011, 12 (05) : 436 - 442
  • [35] Decluster: a complex network model-based data center network topology
    Zhang, Xu
    Wang, Hai
    Gong, Qingyuan
    Wang, Xin
    JOURNAL OF SUPERCOMPUTING, 2014, 70 (03): : 1365 - 1382
  • [36] Decluster: a complex network model-based data center network topology
    Xu Zhang
    Hai Wang
    Qingyuan Gong
    Xin Wang
    The Journal of Supercomputing, 2014, 70 : 1365 - 1382
  • [37] IMPROVING ENERGY EFFICIENCY THROUGH THERMAL CONTROL OF A MODULAR DATA CENTER
    Guinn, John P. E.
    Gondipalli, Srujan
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 7, PTS A-D, 2013, : 725 - 733
  • [38] Model-based synthesis and suppression of transformer alarms in a control center environment
    Dahlgren, R
    Rosenwald, G
    Liu, CC
    Muchlinski, S
    Eide, A
    Sobajic, D
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (03) : 843 - 848
  • [39] Classification of biomedical data through model-based spatial averaging
    Marsolo, K
    Twa, M
    BIBE 2005: 5th IEEE Symposium on Bioinformatics and Bioengineering, 2005, : 49 - 56
  • [40] Refrigeration equipment model construction based in data center cooling station
    Yu, Hang
    Zhang, Tianyi
    Chen, Lei
    Tao, Wen-Quan
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2023, 20 (15) : 1741 - 1749