IMPROVING ENERGY EFFICIENCY THROUGH THERMAL CONTROL OF A MODULAR DATA CENTER

被引:0
|
作者
Guinn, John P. E. [1 ]
Gondipalli, Srujan [2 ]
机构
[1] Hewlett Packard Corp, Houston, TX 77070 USA
[2] Wipro Technol, Houston, TX USA
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
As the IT industry's demand for greater power density racks grows, the operating cost associated with power and cooling IT equipment remains an ever present concern facing data centers. A key component in reducing Total Cost of Ownership (TCO) for a facility is to optimize their cooling system design. Hewlett-Packard has developed a self contained enclosure for high density servers and mass storage devices called a Modular Data Center (MDC). This unit is intended to reduce issues that have plagued large scale data centers by increasing cooling capacity and efficiency. This paper takes a look at the thermal control logic for the MDC and explains ways to decrease energy costs by developing a thermal control scheme centered on optimizing Power Usage Efficiency (PUE). Tests were conducted to understand the relationships between fan power and fan speed, facility power and thermal capacity. Areas of large power drains were isolated and analyzed. Tests showed that there are two parts in managing power usage on the MDC, system and facility control. In the development of a smarter control algorithm, the fans and water valve ("system") performance curves provided a road map to the hardware's capability. This was accomplished by understanding how key variables such as inlet water temperature, water flow rate and fan speed impact the behavior of server inlet air temperature and cooling capacity. Facility control comes from optimizing what equipment is in place to support the MDC (i.e. dedicated chiller, campus chiller, pumps, etc...) within a data center. A significant goal of this project was to minimize the dependency MDC has on external cooling by optimizing the variables that affect facility power. For instance controlling heat removal rate and exiting water temperature affects chiller power; while water flow rate affects pump power. Knowledge of your system and facility's capabilities directly impacts power management. Thermal performance testing of the heat exchanger in the MDC provided insight into how increasing thermal efficiency at the heat exchanger produced an overall drop in facility power. Tests revealed that the optimized thermal control system achieved an infrastructure energy savings up to 33% with a PUE improvement from 1.35 to 1.23 for a 100KW IT heat load. The results show that characterizing and incorporating the behavior of the fans and heat exchanger into the thermal control system produced an improved Power Usage Efficiency (PUB) and a smarter control method.
引用
收藏
页码:725 / 733
页数:9
相关论文
共 50 条
  • [1] Improving Data Center Energy Efficiency With Advanced Thermal Management
    Chainer, Timothy J.
    Schultz, Mark D.
    Parida, Pritish R.
    Gaynes, Michael A.
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2017, 7 (08): : 1228 - 1239
  • [2] Improving Energy Efficiency in Data Center: Challenges and Prospects
    Shi, Chunfeng
    Wang, Qianglin
    2015 2ND INTERNATIONAL CONFERENCE ON EDUCATION AND EDUCATION RESEARCH (EER 2015), PT 5, 2015, 9 : 354 - 357
  • [3] Optics in Data Center: Improving Scalability and Energy Efficiency
    Cerutti, I.
    Andriolli, N.
    Raponi, P. G.
    Castoldi, P.
    Liboiron-Ladouceur, O.
    2014 EUROPEAN CONFERENCE ON NETWORKS AND COMMUNICATIONS (EUCNC), 2014,
  • [4] Data Center Energy Efficiency: Improving Energy Efficiency in Data Centers Beyond Technology Scaling
    Chong, Frederic T.
    Saleh, Adel A. M.
    Heck, Martijn J. R.
    Ranganathan, Parthasarathy
    Wassel, Hassan M. G.
    IEEE DESIGN & TEST, 2014, 31 (01) : 93 - 104
  • [5] Modular Model of a Data Centre as a Tool for Improving Its Energy Efficiency
    Berezovskaya, Yulia
    Yang, Chen-Wei
    Mousavi, Arash
    Vyatkin, Valeriy
    Minde, Tor Bjorn
    IEEE ACCESS, 2020, 8 : 46559 - 46573
  • [6] Thermal awareness to enhance data center energy efficiency
    Grishina, A.
    Chinnici, M.
    Kor, A-L
    De Chiara, D.
    Guarnieri, G.
    Rondeau, E.
    Georges, J. -P.
    CLEANER ENGINEERING AND TECHNOLOGY, 2022, 6
  • [7] Data Center, a cyber-physical system: improving energy efficiency through the power management
    Chinnici, Marta
    De Chiara, Davide
    Quintiliani, Andrea
    2017 IEEE 15TH INTL CONF ON DEPENDABLE, AUTONOMIC AND SECURE COMPUTING, 15TH INTL CONF ON PERVASIVE INTELLIGENCE AND COMPUTING, 3RD INTL CONF ON BIG DATA INTELLIGENCE AND COMPUTING AND CYBER SCIENCE AND TECHNOLOGY CONGRESS(DASC/PICOM/DATACOM/CYBERSCI, 2017, : 269 - 272
  • [8] Improving Data Center Efficiency Through Holistic Scheduling In Kubernetes
    Townend, Paul
    Clement, Stephen
    Burdett, Dan
    Yang, Renyu
    Shaw, Joe
    Slater, Brad
    Xu, Jie
    2019 13TH IEEE INTERNATIONAL CONFERENCE ON SERVICE-ORIENTED SYSTEM ENGINEERING (SOSE) / 10TH INTERNATIONAL WORKSHOP ON JOINT CLOUD COMPUTING (JCC) / IEEE INTERNATIONAL WORKSHOP ON CLOUD COMPUTING IN ROBOTIC SYSTEMS (CCRS), 2019, : 156 - 166
  • [9] Improving Building Energy Efficiency through Data Analysis
    Phillip, DiAndra
    Chen, Jin
    Maksakuli, Fani
    Ruci, Arber
    Sturdivant, E'edresha
    Zhu, Zhigang
    E-ENERGY '23 COMPANION-PROCEEDINGS OF THE 2023 THE 14TH ACM INTERNATIONAL CONFERENCE ON FUTURE ENERGY SYSTEMS, 2023, : 1 - 7
  • [10] MAXIMIZING DATA CENTER ENERGY EFFICIENCY BY UTILIZING NEW THERMAL MANAGEMENT AND ACOUSTIC CONTROL METHODOLOGY
    Matteson, Jason A.
    Vallury, Aparna
    Medlin, Billy
    PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2013, VOL 2, 2014,