Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy

被引:156
|
作者
Shirato, H
Suzuki, K
Sharp, GC
Fujita, K
Onimaru, R
Fujino, M
Kato, N
Osaka, Y
Kinoshita, R
Taguchi, H
Onodera, S
Miyasaka, K
机构
[1] Hokkaido Univ, Sch Med, Dept Radiol, Sapporo, Hokkaido 0608636, Japan
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiat Oncol, Boston, MA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 64卷 / 04期
关键词
four-dimensional radiotherapy; setup; real-time tracking; four-dimensional setup;
D O I
10.1016/j.ijrobp.2005.11.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To reduce the uncertainty of registration for lung tumors, we have developed a four-dimensional (4D) setup system using a real-time tumor-tracking radiotherapy system. Methods and Materials: During treatment planning and daily setup in the treatment room, the trajectory of the internal fiducial marker was recorded for 1 to 2 min at the rate of 30 times per second by the real-time tumor-tracking radiotherapy system. To maximize gating efficiency, the patient's position on the treatment couch was adjusted using the 4D setup system with fine on-line remote control of the treatment couch. Results: The trajectory of the marker detected in the 4D setup system was well visualized and used for daily setup. Various degrees of interfractional and intrafractional changes in the absolute amplitude and speed of the internal marker were detected. Readjustments were necessary during each treatment session, prompted by baseline shifting of the tumor position. Conclusion: The 4D setup system was shown to be useful for reducing the uncertainty of tumor motion and for increasing the efficiency of gated irradiation. Considering the interfractional and intrafractional changes in speed and amplitude detected in this study, intercepting radiotherapy is the safe and cost-effective method for 4D radiotherapy using real-time tracking technology. (C) 2006 Elsevier Inc.
引用
收藏
页码:1229 / 1236
页数:8
相关论文
共 50 条
  • [31] Real-time tumor-tracking radiotherapy with SyncTraX for primary liver tumors requiring isocenter shift
    Uchinami, Yusuke
    Miyamoto, Naoki
    Abo, Daisuke
    Morita, Ryo
    Ogawa, Koji
    Kakisaka, Tatsuhiko
    Suzuki, Ryusuke
    Miyazaki, Tomohiko
    Taguchi, Hiroshi
    Katoh, Norio
    Aoyama, Hidefumi
    JOURNAL OF RADIATION RESEARCH, 2024, 65 (01) : 92 - 99
  • [32] Endoscopic placement of fiducial markers for real-time tumor-tracking radiotherapy in 50 patients with lung cancer: A feasibility study
    Blaukovitsch, Markus
    Lamprecht, Bernd
    Wegleitner, Birgit
    Porsch, Peter
    Wurstbauer, Karl
    Sedlmayer, Franz
    Studnicka, Michael
    EUROPEAN RESPIRATORY JOURNAL, 2013, 42
  • [33] Endoscopic placement of fiducial markers for real-time tumor-tracking radiotherapy in 50 patients with lung cancer: a feasibility study
    Blaukovitsch, M.
    Lamprecht, B.
    Wegleitner, B.
    Porsch, P.
    Wurstbauer, K.
    Sedlmayer, F.
    Sedlmayer, M.
    WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 (19-20) : 647 - 647
  • [34] Improvement of Tracking Accuracy and Stability with Utilizing a Color Image Intensifier in Real-time Tumor-tracking Radiotherapy System
    Miyamoto, N.
    Ishikawa, M.
    Bengua, G.
    Sutherland, K.
    Suzuki, R.
    Shirato, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S678 - S678
  • [35] Motion Adaptive Image Filter for Low Dose X-Ray Fluoroscopy in the Real-Time Tumor-Tracking Radiotherapy System
    Miyamoto, N.
    Ishikawa, M.
    Sutherland, K.
    Suzuki, R.
    Matsuura, T.
    Takao, S.
    Toramatsu, C.
    Nihongi, H.
    Shimizu, S.
    Onimaru, R.
    Umegaki, K.
    Shirato, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3661 - 3662
  • [36] Patient-specific respiratory motion management using lung tumors vs fiducial markers for real-time tumor-tracking stereotactic body radiotherapy
    Tanabe, Yoshinori
    Kiritani, Michiru
    Deguchi, Tomomi
    Hira, Nanami
    Tomimoto, Syouta
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 25
  • [37] Four-dimensional multislice computed tomography for determination of respiratory lung tumor motion in conformal radiotherapy
    Leter, EM
    Cademartiri, F
    Levendag, PC
    Flohr, T
    Stam, H
    Nowak, PJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03): : 888 - 892
  • [38] Dynamic tumor-tracking radiotherapy with real-time monitoring for liver tumors using a gimbal mounted linac
    Iizuka, Yusuke
    Matsuo, Yukinori
    Ishihara, Yoshitomo
    Akimoto, Mami
    Tanabe, Hiroaki
    Takayama, Kenji
    Ueki, Nami
    Yokota, Kenji
    Mizowaki, Takashi
    Kokubo, Masaki
    Hiraoka, Masahiro
    RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) : 496 - 500
  • [39] Stereotactic body radiotherapy using gated radiotherapy with real-time tumor-tracking for stage I non-small cell lung cancer
    Tetsuya Inoue
    Norio Katoh
    Rikiya Onimaru
    Shinichi Shimizu
    Kazuhiko Tsuchiya
    Ryusuke Suzuki
    Jun Sakakibara-Konishi
    Naofumi Shinagawa
    Satoshi Oizumi
    Hiroki Shirato
    Radiation Oncology, 8
  • [40] Optimization of fluoroscopy parameters using pattern matching prediction in the real-time tumor-tracking radiotherapy system
    Miyamoto, Naoki
    Ishikawa, Masayori
    Bengua, Gerard
    Sutherland, Kenneth
    Suzuki, Ryusuke
    Kimura, Suguru
    Shimizu, Shinichi
    Onimaru, Rikiya
    Shirato, Hiroki
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15): : 4803 - 4813