Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy

被引:156
|
作者
Shirato, H
Suzuki, K
Sharp, GC
Fujita, K
Onimaru, R
Fujino, M
Kato, N
Osaka, Y
Kinoshita, R
Taguchi, H
Onodera, S
Miyasaka, K
机构
[1] Hokkaido Univ, Sch Med, Dept Radiol, Sapporo, Hokkaido 0608636, Japan
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiat Oncol, Boston, MA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 64卷 / 04期
关键词
four-dimensional radiotherapy; setup; real-time tracking; four-dimensional setup;
D O I
10.1016/j.ijrobp.2005.11.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To reduce the uncertainty of registration for lung tumors, we have developed a four-dimensional (4D) setup system using a real-time tumor-tracking radiotherapy system. Methods and Materials: During treatment planning and daily setup in the treatment room, the trajectory of the internal fiducial marker was recorded for 1 to 2 min at the rate of 30 times per second by the real-time tumor-tracking radiotherapy system. To maximize gating efficiency, the patient's position on the treatment couch was adjusted using the 4D setup system with fine on-line remote control of the treatment couch. Results: The trajectory of the marker detected in the 4D setup system was well visualized and used for daily setup. Various degrees of interfractional and intrafractional changes in the absolute amplitude and speed of the internal marker were detected. Readjustments were necessary during each treatment session, prompted by baseline shifting of the tumor position. Conclusion: The 4D setup system was shown to be useful for reducing the uncertainty of tumor motion and for increasing the efficiency of gated irradiation. Considering the interfractional and intrafractional changes in speed and amplitude detected in this study, intercepting radiotherapy is the safe and cost-effective method for 4D radiotherapy using real-time tracking technology. (C) 2006 Elsevier Inc.
引用
收藏
页码:1229 / 1236
页数:8
相关论文
共 50 条
  • [21] Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System
    Takao, Seishin
    Miyamoto, Naoki
    Matsuura, Taeko
    Onimaru, Rikiya
    Katoh, Norio
    Inoue, Tetsuya
    Sutherland, Kenneth Lee
    Suzuki, Ryusuke
    Shirato, Hiroki
    Shimizu, Shinichi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (01): : 172 - 180
  • [22] Evaluation of Time Delay and Fluoroscopic Dose in a New Real-Time Tumor-Tracking Radiotherapy System
    Kitagawa, Masayasu
    Hirosawa, Ayaka
    Takemura, Akihiro
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 487 - 491
  • [23] Application of real-time tumor-tracking and gated radiotherapy system for unresectable pancreatic cancer
    Ahn, YC
    Shimizuz, S
    Shirato, H
    Hashimoto, T
    Osaka, Y
    Zhang, XQ
    Abe, T
    Hosokawa, M
    Miyasaka, K
    YONSEI MEDICAL JOURNAL, 2004, 45 (04) : 584 - 590
  • [24] Histopathologic consideration of fiducial gold markers inserted for real-time tumor-tracking radiotherapy against lung cancer
    Imura, Mikado
    Yamazaki, Koichi
    Kubota, Kanako C.
    Itoh, Tomoo
    Onimaru, Rikiya
    Cho, Yasushi
    Hida, Yasuhiro
    Kaga, Kichizo
    Onodera, Yuya
    Ogura, Shigeaki
    Dosaka-Akita, Hirotoshi
    Shirato, Hiroki
    Nishimura, Masaharu
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02): : 382 - 384
  • [25] Development of a four-dimensional Monte Carlo dose calculation system for real-time tumor-tracking irradiation with a gimbaled X-ray head
    Ishihara, Yoshitomo
    Nakamura, Mitsuhiro
    Miyabe, Yuki
    Mukumoto, Nobutaka
    Matsuo, Yukinori
    Sawada, Akira
    Kokubo, Masaki
    Mizowaki, Takashi
    Hiraoka, Masahiro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 35 : 59 - 65
  • [26] Real-Time Tumor-Tracking Radiotherapy and General Stereotactic Body Radiotherapy for Adrenal Metastasis in Patients With Oligometastasis
    Katoh, Norio
    Onishi, Hiroshi
    Uchinami, Yusuke
    Inoue, Tetsuya
    Kuriyama, Kengo
    Nishioka, Kentaro
    Shimizu, Shinichi
    Komiyama, Takafumi
    Miyamoto, Naoki
    Shirato, Hiroki
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2018, 17
  • [27] Improvement of tracking accuracy and stability by recursive image processing in real-time tumor-tracking radiotherapy system
    Miyamoto, Naoki
    Sutherland, Kenneth
    Suzuki, Ryusuke
    Matsuura, Taeko
    Toramatsu, Chie
    Takao, Seishin
    Nihongi, Hideaki
    Kinoshita, Rumiko
    Shimizu, Shinichi
    Onimaru, Rikiya
    Umegaki, Kikuo
    Shirato, Hiroki
    Ishikawa, Masayori
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [28] Investigation of four-dimensional (4D) Monte Carlo dose calculation in real-time tumor tracking stereotatic body radiotherapy for lung cancers
    Chan, Mark K. H.
    Kwong, Dora L. W.
    Ng, Sherry C. Y.
    Tam, Eric K. W.
    Tong, Anthony S. M.
    MEDICAL PHYSICS, 2012, 39 (09) : 5479 - 5487
  • [29] A motion-compensated image filter for low-dose fluoroscopy in a real-time tumor-tracking radiotherapy system
    Miyamoto, Naoki
    Ishikawa, Masayori
    Sutherland, Kenneth
    Suzuki, Ryusuke
    Matsuura, Taeko
    Toramatsu, Chie
    Takao, Seishin
    Nihongi, Hideaki
    Shimizu, Shinichi
    Umegaki, Kikuo
    Shirato, Hiroki
    JOURNAL OF RADIATION RESEARCH, 2015, 56 (01) : 186 - 196
  • [30] Real-time Tumor-tracking Radiation Therapy for Lymphoma of the Stomach
    Katoh, N.
    Suzuki, R.
    Shimizu, S.
    Inoue, T.
    Yasuda, K.
    Onimaru, R.
    Kimura, R.
    Kato, M.
    Ishikawa, M.
    Shirato, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S722 - S722