Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy

被引:156
|
作者
Shirato, H
Suzuki, K
Sharp, GC
Fujita, K
Onimaru, R
Fujino, M
Kato, N
Osaka, Y
Kinoshita, R
Taguchi, H
Onodera, S
Miyasaka, K
机构
[1] Hokkaido Univ, Sch Med, Dept Radiol, Sapporo, Hokkaido 0608636, Japan
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiat Oncol, Boston, MA USA
关键词
four-dimensional radiotherapy; setup; real-time tracking; four-dimensional setup;
D O I
10.1016/j.ijrobp.2005.11.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To reduce the uncertainty of registration for lung tumors, we have developed a four-dimensional (4D) setup system using a real-time tumor-tracking radiotherapy system. Methods and Materials: During treatment planning and daily setup in the treatment room, the trajectory of the internal fiducial marker was recorded for 1 to 2 min at the rate of 30 times per second by the real-time tumor-tracking radiotherapy system. To maximize gating efficiency, the patient's position on the treatment couch was adjusted using the 4D setup system with fine on-line remote control of the treatment couch. Results: The trajectory of the marker detected in the 4D setup system was well visualized and used for daily setup. Various degrees of interfractional and intrafractional changes in the absolute amplitude and speed of the internal marker were detected. Readjustments were necessary during each treatment session, prompted by baseline shifting of the tumor position. Conclusion: The 4D setup system was shown to be useful for reducing the uncertainty of tumor motion and for increasing the efficiency of gated irradiation. Considering the interfractional and intrafractional changes in speed and amplitude detected in this study, intercepting radiotherapy is the safe and cost-effective method for 4D radiotherapy using real-time tracking technology. (C) 2006 Elsevier Inc.
引用
收藏
页码:1229 / 1236
页数:8
相关论文
共 50 条
  • [1] Fluctuation in speed and amplitude of lung tumor motion detected by real-time tumor-tracking radiotherapy system
    Onodeara, S
    Fujino, M
    Fujita, K
    Onimaru, R
    Aoyama, H
    Sharp, G
    Shirato, H
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S86 - S87
  • [2] Real-time tumor-tracking and four-dimensional radiotherapy
    Shirato, H. (shirato@med.hokudai.ac.jp), 1600, Institute of Electronics Information and Communication Eng., Annex 3F, 5-22, Shibakoen 3 chome, Minato-ku, Tokyo, 105-0011, Japan (96):
  • [3] Detection of lung tumor movement in real-time tumor-tracking radiotherapy
    Shimizu, S
    Shirato, H
    Ogura, S
    Akita-Dosaka, H
    Kitamura, K
    Nishioka, T
    Kagei, K
    Nishimura, M
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (02): : 304 - 310
  • [4] Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
    Shirato, H
    Shimizu, S
    Kitamura, K
    Nishioka, T
    Kagei, K
    Hashimoto, S
    Aoyama, H
    Kunieda, T
    Shinohara, N
    Dosaka-Akita, H
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02): : 435 - 442
  • [5] Real-time tumor-tracking radiotherapy for adrenal tumors
    Katoh, Norio
    Onimaru, Rikiya
    Sakuhara, Yusuke
    Abo, Daisuke
    Shimizu, Shinichi
    Taguchi, Hiroshi
    Watanabe, Yoshiaki
    Shinohara, Nobuo
    Ishikawa, Masayori
    Shirato, Hiroki
    RADIOTHERAPY AND ONCOLOGY, 2008, 87 (03) : 418 - 424
  • [6] Baseline Shift of Intrafractional Lung Tumor Motion in Real-Time Tumor-Tracking Radiation Therapy
    Takao, S.
    Miyamoto, N.
    Matsuura, T.
    Shimizu, S.
    Onimaru, R.
    Katoh, N.
    Inoue, T.
    Shirato, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S67 - S67
  • [7] Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy
    Shirato, Hiroki
    Shimizu, Shinichi
    Kitamura, Kei
    Onimaru, Rikiya
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2007, 12 (01) : 8 - 16
  • [8] Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy
    Hiroki Shirato
    Shinichi Shimizu
    Kei Kitamura
    Rikiya Onimaru
    International Journal of Clinical Oncology, 2007, 12 : 8 - 16
  • [9] Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    Shirato, H
    Shimizu, S
    Kunieda, T
    Kitamura, K
    van Herk, M
    Kagei, K
    Nishioka, T
    Hashimoto, S
    Fujita, K
    Aoyama, H
    Tsuchiya, K
    Kudo, K
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04): : 1187 - 1195
  • [10] Evaluation of the motion of lung tumors during stereotactic body radiation therapy (SBRT) with four-dimensional computed tomography (4DCT) using real-time tumor-tracking radiotherapy system (RTRT)
    Harada, Keiichi
    Katoh, Norio
    Suzuki, Ryusuke
    Ito, Yoichi M.
    Shimizu, Shinichi
    Onimaru, Rikiya
    Inoue, Tetsuya
    Miyamoto, Naoki
    Shirato, Hiroki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 305 - 311