Absolute linearity measurements on a PbS detector in the infrared

被引:26
|
作者
Theocharous, E [1 ]
机构
[1] Natl Phys Lab, Div Qual Life, Opt Radiat Team, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1364/AO.45.002381
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The nonlinearity characteristics of a commercially available thin-film photoconductive PbS detector were experimentally investigated in the infrared using the National Physical Laboratory detector linearity characterization facility. The deviation from linearity of this detector was shown to be significant even for relatively low values of radiant power incident on the active area of the detector. For example, the linearity factor was approximately 0.8 when 0.6 mu W of radiant power at a wavelength of 2.2 mu m was illuminating a spot of 1 mm in diameter on the active area of the PbS detector. These figures demonstrate the poor linearity characteristics of this detector and provide a warning to other users of PbS detection systems. The deviation from linearity was shown to be a function of the size of the spot being illuminated on the detector active area, as well as the wavelength of the incident radiation. The deviation from linearity was shown to be a function of irradiance illuminating the detector for irradiance values lower than 1 mu W mm(-2). (c) 2006 Optical Society of America.
引用
收藏
页码:2381 / 2386
页数:6
相关论文
共 50 条
  • [21] ABSOLUTE MEASUREMENTS OF INFRARED APPARENT TEMPERATURES OF LUNAR MARIA
    GAY, J
    RABBIA, Y
    BOUDON, Y
    CORTEGGIANI, JP
    FUTAULLY, R
    GAIGNEBET, N
    GRANES, P
    KOVALEVSKY, J
    SAGNIER, JL
    TORRE, JM
    VILLAIN, JP
    WALCH, JJ
    MOON AND THE PLANETS, 1980, 23 (02): : 203 - 211
  • [22] Experimental study of PbS detector irradiated by 2.79 μm mid-infrared laser
    Wang Xi
    Ye Qing
    Dong Xiao
    Lei Wu-Hu
    Lyu Tong-Lin
    Guo Yan-Tin
    Hu Yi-Hua
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2022, 41 (01) : 354 - 361
  • [23] Absolute detector quantum-efficiency measurements using correlated photons
    Migdall, AL
    Datla, RU
    Sergienko, A
    Orszak, JS
    Shih, YH
    METROLOGIA, 1996, 32 (06) : 479 - 483
  • [24] Absolute efficiency measurements with the 10B based Jalousie detector
    Modzel, G.
    Henske, M.
    Houben, A.
    Klein, M.
    Koehli, M.
    Lennert, R.
    Meven, M.
    Schmidt, C. J.
    Schmidt, U.
    Schweika, W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 743 : 90 - 95
  • [25] Absolute measurements in the VUV spectral range in the aid of a luminescent detector.
    Shevelko, AP
    KVANTOVAYA ELEKTRONIKA, 1996, 23 (08): : 748 - 750
  • [26] ABSOLUTE FAST NEUTRAL BEAM FLUX MEASUREMENTS USING A PYROELECTRIC DETECTOR
    GEIS, MW
    SMITH, KA
    RUNDEL, RD
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1975, 8 (12): : 1011 - 1014
  • [27] Note: Near infrared spectral and transient measurements of PbS quantum dots luminescence
    Parfenov, P. S.
    Litvin, A. P.
    Ushakova, E. V.
    Fedorov, A. V.
    Baranov, A. V.
    Berwick, K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (11):
  • [28] Angle-dependent absolute infrared reflectance and transmittance measurements
    Kaplan, SG
    Hanssen, LM
    OPTICAL DIAGNOSTIC METHODS FOR INORGANIC MATERIALS II, 2000, 4103 : 75 - 84
  • [29] Extracting Infrared Absolute Reflectance from Relative Reflectance Measurements
    Berets, Susan L.
    Milosevic, Milan
    APPLIED SPECTROSCOPY, 2012, 66 (06) : 680 - 684
  • [30] ABSOLUTE INFRARED INTENSITY MEASUREMENTS ON NITROGEN DIOXIDE AND DINITROGEN TETROXIDE
    GUTTMAN, A
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1962, 2 (01): : 1 - 15