Non-invasive measurement of arterial pressure-dependent compliance

被引:0
|
作者
Liu, Changchun [1 ]
Xin, Sun [1 ]
Liu, Chengyu [1 ]
Gu, Jason J. [1 ]
Yu, Mengsun [1 ]
机构
[1] Shandong Univ, Sch Control Sci & Engn, Jinan 250061, Peoples R China
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Pressure-dependent compliance is able to better reflect the degree of the arterial tree stiffness. Many researchers apply Windkessel model to evaluate compliance of the arterial tree. However, this model assumes that the compliance is not related to the blood pressure, which is not valid for the high pressure situation, thus this paper proposed an improved nonlinear model for analyzing the pressure waveform obtained from human radial artery with a precise pressure waveform acquisition device. The electrical model for analysis in this study mainly contains a nonlinear capacitor that simulates the nonlinear pressure-dependent compliance of the whole human arterial tree and a resistor that simulates flow resistances of the small arteries and arterioles. Since the nonlinear pressure-dependent compliance C(p) is determined by blood pressure p(l), the relation between compliance and blood pressure of human arterial tree is expressed as C(p)=a center dot exp(-b center dot p(t)), where the parameters a and b are constants determined from curve fitting of experimentally measured radial artery pressure waveform. Besides localization and data collection, the acquisition device can also provide a preset pressure on the radial artery before measurement and hold this pressure during measurement. The pressure waveform obtained from the device, then, is calibrated by blood pressure measured using clinical sphygmomanometer. The pressure waveform after calibration is segmented into a series of single-cycle waveforms using a threshold algorithm. For each single-cycle waveform, the dicrotic notch is identified, which indicates the start of the diastolic period. After diastolic waveform identification of each single-cycle waveform, the optimal a and b are determined by curve fitting of each diastolic waveform. The nonlinear compliance C(p) shows the relationship between arterial tree compliance and blood pressure, which is very useful for physicians to diagnose arteriosclerosis and hypertension, and provides a new perspective to the understanding of cardiovascular diseases. Experiment has been carried out to evaluate the pressure-dependent compliance. The results have been provided.
引用
收藏
页码:590 / 593
页数:4
相关论文
共 50 条
  • [31] Comparison of Non-invasive and Invasive Arterial Blood Pressure Measurement for Assessment of Dynamic Cerebral Autoregulation
    Petersen, Nils H.
    Ortega-Gutierrez, Santiago
    Reccius, Andres
    Masurkar, Arjun
    Huang, Amy
    Marshall, Randolph S.
    NEUROCRITICAL CARE, 2014, 20 (01) : 60 - 68
  • [32] CONTINUOUS NON-INVASIVE ARTERIAL PRESSURE (CNAP) MEASUREMENT: COMPARING THE CNAP DEVICE TO THE NON-INVASIVE BLOOD PRESSURE ARM CUFF DURING SURGERY
    Khera, J. K.
    Solangasenathirajan, S.
    Jones, M.
    Jonas, M.
    INTENSIVE CARE MEDICINE, 2013, 39 : S295 - S295
  • [33] Non-invasive measurement of intracranial compliance using cine MRI in normal pressure hydrocephalus
    Mase, M
    Miyati, T
    Yamada, K
    Kasai, H
    Hara, M
    Shibamoto, Y
    Intracranial Pressure and Brain Monitoring XII, 2005, 95 : 303 - 306
  • [34] A novel magnetic plethysmograph for non-invasive evaluation of arterial compliance
    Chandrasekhar, Anand
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1169 - 1172
  • [35] Non-invasive characterization of total arterial compliance by simultaneous acquisition of pressure and flow: Advantages of the pulse pressure method
    Carlier, S
    Segers, P
    Pasquet, A
    Armstrong, G
    Greenberg, NL
    Stergiopulos, N
    Marwick, T
    Thomas, JD
    COMPUTERS IN CARDIOLOGY 1998, VOL 25, 1998, 25 : 665 - 668
  • [36] NON-INVASIVE MEASUREMENT OF SLOPE OF ARTERIAL-PRESSURE CURVE IN LOWER EXTREMITIES OF PATIENTS WITH ARTERIAL OCCLUSION
    JOHNSTON, KW
    KAKKAR, VV
    BRITISH JOURNAL OF SURGERY, 1973, 60 (11) : 913 - 914
  • [37] Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement
    Ilies, C.
    Bauer, M.
    Berg, P.
    Rosenberg, J.
    Hedderich, J.
    Bein, B.
    Hinz, J.
    Hanss, R.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (02) : 202 - 210
  • [38] Evaluation of a continuous non-invasive arterial blood pressure monitoring device in comparison with an arterial blood pressure measurement in the ICU
    K Smolle
    M Schmid
    Critical Care, 15 (Suppl 1):
  • [39] Reliability of non-invasive arterial blood pressure measurement in patients with aneurysmal subarachnoid haemorrhage
    Olsen, Markus Harboe
    Riberholt, Christian Gunge
    Capion, Tenna
    Berg, Ronan M. G.
    Moller, Kirsten
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
  • [40] NON-INVASIVE MEASUREMENT OF PULMONARY ARTERIAL-PRESSURE .2. A RADIONUCLIDE METHOD
    BOURGUIGNON, MH
    LEGULUDEC, D
    VALETTE, H
    DAVY, J
    MOTTE, G
    ODDOU, C
    BUCHANAN, JW
    RAYNAUD, C
    SYROTA, A
    WAGNER, HN
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (02): : 215 - 225