Non-invasive measurement of arterial pressure-dependent compliance

被引:0
|
作者
Liu, Changchun [1 ]
Xin, Sun [1 ]
Liu, Chengyu [1 ]
Gu, Jason J. [1 ]
Yu, Mengsun [1 ]
机构
[1] Shandong Univ, Sch Control Sci & Engn, Jinan 250061, Peoples R China
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Pressure-dependent compliance is able to better reflect the degree of the arterial tree stiffness. Many researchers apply Windkessel model to evaluate compliance of the arterial tree. However, this model assumes that the compliance is not related to the blood pressure, which is not valid for the high pressure situation, thus this paper proposed an improved nonlinear model for analyzing the pressure waveform obtained from human radial artery with a precise pressure waveform acquisition device. The electrical model for analysis in this study mainly contains a nonlinear capacitor that simulates the nonlinear pressure-dependent compliance of the whole human arterial tree and a resistor that simulates flow resistances of the small arteries and arterioles. Since the nonlinear pressure-dependent compliance C(p) is determined by blood pressure p(l), the relation between compliance and blood pressure of human arterial tree is expressed as C(p)=a center dot exp(-b center dot p(t)), where the parameters a and b are constants determined from curve fitting of experimentally measured radial artery pressure waveform. Besides localization and data collection, the acquisition device can also provide a preset pressure on the radial artery before measurement and hold this pressure during measurement. The pressure waveform obtained from the device, then, is calibrated by blood pressure measured using clinical sphygmomanometer. The pressure waveform after calibration is segmented into a series of single-cycle waveforms using a threshold algorithm. For each single-cycle waveform, the dicrotic notch is identified, which indicates the start of the diastolic period. After diastolic waveform identification of each single-cycle waveform, the optimal a and b are determined by curve fitting of each diastolic waveform. The nonlinear compliance C(p) shows the relationship between arterial tree compliance and blood pressure, which is very useful for physicians to diagnose arteriosclerosis and hypertension, and provides a new perspective to the understanding of cardiovascular diseases. Experiment has been carried out to evaluate the pressure-dependent compliance. The results have been provided.
引用
收藏
页码:590 / 593
页数:4
相关论文
共 50 条
  • [21] Non-invasive measurement of arterial longitudinal movement
    Persson, M
    Ahlgren, AR
    Eriksson, A
    Jansson, T
    Persson, HW
    Lindström, K
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1783 - 1786
  • [22] Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement
    Hidehiko Komine
    Yoshiyuki Asai
    Takashi Yokoi
    Mutsuko Yoshizawa
    BioMedical Engineering OnLine, 11
  • [23] Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement
    Komine, Hidehiko
    Asai, Yoshiyuki
    Yokoi, Takashi
    Yoshizawa, Mutsuko
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [24] Determination of appropriate recording force for non-invasive measurement of arterial pressure pulses
    Driscoll, MD
    Arnold, JMO
    Marchiori, GE
    Harker, LA
    Sherebrin, MH
    CLINICAL SCIENCE, 1997, 92 (06) : 559 - 566
  • [25] Feasibility of non-invasive measurement of central blood pressure and arterial stiffness in shock
    Markakis, Konstantinos
    Pagonas, Nikolaos
    Georgianou, Eleni
    Zgoura, Panagiota
    Rohn, Benjamin J.
    Bertram, Sebastian
    Seidel, Maximilian
    Bettag, Sebastian
    Trappe, Hans-Joachim
    Babel, Nina
    Westhoff, Timm H.
    Seibert, Felix S.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2021, 51 (09)
  • [26] Non-invasive arterial pressure monitoring revisited
    Frederic Michard
    Daniel I. Sessler
    Bernd Saugel
    Intensive Care Medicine, 2018, 44 : 2213 - 2215
  • [27] NON-INVASIVE MEASUREMENT OF SYSTEMIC ARTERIAL-PRESSURE IN DOGS BY AUTOMATIC SPHYGMOMANOMETRY
    HAMLIN, RL
    KITTLESON, MD
    RICE, D
    KNOWLEN, G
    SEYFFERT, R
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1982, 43 (07) : 1271 - 1273
  • [28] Non-invasive arterial pressure monitoring revisited
    Michard, Frederic
    Sessler, Daniel I.
    Saugel, Bernd
    INTENSIVE CARE MEDICINE, 2018, 44 (12) : 2213 - 2215
  • [29] Reliability Of Non-Invasive Continuous Arterial Pressure Measurement Devices During Total Invasive Anaesthesia
    Huhle, R.
    Siegert, J.
    de Abreu, M. Gama
    Koch, T.
    Theilen, H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [30] Comparison of Non-invasive and Invasive Arterial Blood Pressure Measurement for Assessment of Dynamic Cerebral Autoregulation
    Nils H. Petersen
    Santiago Ortega-Gutierrez
    Andres Reccius
    Arjun Masurkar
    Amy Huang
    Randolph S. Marshall
    Neurocritical Care, 2014, 20 : 60 - 68