Non-invasive measurement of arterial pressure-dependent compliance

被引:0
|
作者
Liu, Changchun [1 ]
Xin, Sun [1 ]
Liu, Chengyu [1 ]
Gu, Jason J. [1 ]
Yu, Mengsun [1 ]
机构
[1] Shandong Univ, Sch Control Sci & Engn, Jinan 250061, Peoples R China
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Pressure-dependent compliance is able to better reflect the degree of the arterial tree stiffness. Many researchers apply Windkessel model to evaluate compliance of the arterial tree. However, this model assumes that the compliance is not related to the blood pressure, which is not valid for the high pressure situation, thus this paper proposed an improved nonlinear model for analyzing the pressure waveform obtained from human radial artery with a precise pressure waveform acquisition device. The electrical model for analysis in this study mainly contains a nonlinear capacitor that simulates the nonlinear pressure-dependent compliance of the whole human arterial tree and a resistor that simulates flow resistances of the small arteries and arterioles. Since the nonlinear pressure-dependent compliance C(p) is determined by blood pressure p(l), the relation between compliance and blood pressure of human arterial tree is expressed as C(p)=a center dot exp(-b center dot p(t)), where the parameters a and b are constants determined from curve fitting of experimentally measured radial artery pressure waveform. Besides localization and data collection, the acquisition device can also provide a preset pressure on the radial artery before measurement and hold this pressure during measurement. The pressure waveform obtained from the device, then, is calibrated by blood pressure measured using clinical sphygmomanometer. The pressure waveform after calibration is segmented into a series of single-cycle waveforms using a threshold algorithm. For each single-cycle waveform, the dicrotic notch is identified, which indicates the start of the diastolic period. After diastolic waveform identification of each single-cycle waveform, the optimal a and b are determined by curve fitting of each diastolic waveform. The nonlinear compliance C(p) shows the relationship between arterial tree compliance and blood pressure, which is very useful for physicians to diagnose arteriosclerosis and hypertension, and provides a new perspective to the understanding of cardiovascular diseases. Experiment has been carried out to evaluate the pressure-dependent compliance. The results have been provided.
引用
收藏
页码:590 / 593
页数:4
相关论文
共 50 条
  • [1] Non-invasive estimation of arterial compliance
    Joseph, Jayaraj
    Venkataraman, Jayashankar
    Kumar, Jagadeesh, V
    Suresh, S.
    2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 480 - 484
  • [2] NON-INVASIVE DETERMINATION OF ARTERIAL COMPLIANCE
    CHAI, SD
    NING, XH
    CHOU, CN
    CHOU, ZM
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (04) : 424 - 429
  • [3] Arterial compliance measurement using a non-invasive laser Doppler measurement system
    Hast, J
    Myllylä, R
    Sorvoja, H
    Nissilä, S
    OPTICAL TECHNIQUES AND INSTRUMENTATION FOR THE MEASUREMENT OF BLOOD COMPOSITION, STRUCTURE AND DYNAMICS, 2000, 4163 : 24 - 32
  • [4] A Novel Algorithm for Estimating Arterial Pressure-dependent Compliance
    Sun Xin
    Liu Changchun
    Yang Lei
    Zhang Yaohua
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 243 - 245
  • [5] A non-invasive pulse pressure method for the estimation of total arterial compliance
    Segers, P
    Stergiopulos, N
    Verdonck, P
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 171 - 174
  • [6] The pulse pressure method for non-invasive evaluation of total arterial compliance
    Carlier, S
    Segers, P
    De Backer, T
    Stergiopoulos, N
    Thomas, J
    JOURNAL OF HYPERTENSION, 2000, 18 : S197 - S197
  • [7] TOWARDS ACCURATE NON-INVASIVE MEASUREMENT OF ARTERIAL-PRESSURE
    FINNIE, KJC
    ARMSTRONG, PW
    CLINICAL RESEARCH, 1980, 28 (02): : A168 - A168
  • [8] A new indicator for non-invasive arterial blood pressure measurement
    Regueiro-Gomez, A
    Pallas-Areny, R
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 117 - 118
  • [9] A NONLINEAR MODEL OF THE ARTERIAL SYSTEM INCORPORATING A PRESSURE-DEPENDENT COMPLIANCE
    LI, JKJ
    CUI, T
    DRZEWIECKI, GM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (07) : 673 - 678
  • [10] A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis
    Jiang, Ziqing
    Li, Shaoying
    Wang, Lin
    Yu, Feng
    Zeng, Yanping
    Li, Hongbo
    Li, Jun
    Zhang, Zhanfeng
    Zuo, Junling
    JOURNAL OF ANESTHESIA, 2024, 38 (02) : 222 - 231