Reliability of Predictors for Screw Cutout in Intertrochanteric Hip Fractures

被引:136
|
作者
De Bruijn, Kirstin [1 ]
den Hartog, Dennis
Tuinebreijer, Wim
Roukema, Gert
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC, Dept Surg, NL-3000 CA Rotterdam, Netherlands
来源
关键词
TIP-APEX DISTANCE; FIXATION; FAILURE; FEMUR; NAIL;
D O I
10.2106/JBJS.K.00357
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Following internal fixation of intertrochanteric hip fractures, tip apex distance, fracture classification, position of the screw in the femoral head, and fracture reduction are known predictors for screw cutout, but the reliability of these measurements is unknown. We investigated the reliability of the tip apex distance measurement, the Cleveland femoral head dividing system, the three-grade classification system of Baumgaertner for fracture reduction, and the AO classification system as predictors for screw cutout. Methods: All patients with an intertrochanteric hip fracture who were managed with either a dynamic hip screw or a gamma nail between January 2007 and June 2010 were evaluated from our hip trauma database. Results: The tip apex distance measurement was reliable and patients with device cutout had a significantly higher tip apex distance. The agreement between observers with regard to screw position and fracture reduction was moderately reliable. After adjustment for tip apex distance and screw position, A3 fractures were at more risk of cutout compared with A1 fractures. Poor fracture reduction was significantly related with a higher incidence of cutout in univariate analysis, but not in multivariate analysis. Central-inferior and anterior-inferior positions, after adjustment for tip apex distance and screw position, were significantly protective against cutout. Conclusion: To decrease probable risks of cutout, the tip apex distance needs to stay small or the screw needs to be placed central-inferiorly or anterior-inferiorly. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
引用
收藏
页码:1266 / 1272
页数:7
相关论文
共 50 条
  • [41] Perioperative Lateral Trochanteric Hip Fractures: Sliding Hip Screw Versus Percutaneous Compression Plate for Intertrochanteric Hip Fractures In Response
    Langford, Joshua
    Yang, Edward
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (09) : E96 - E96
  • [42] A prospective trial comparing the Holland nail with the dynamic hip screw in the treatment of intertrochanteric fractures of the hip
    Little, N. J.
    Verma, V.
    Fernando, C.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (08): : 1073 - 1078
  • [43] Percutaneous compression plating versus compression hip screw fixation for the treatment of intertrochanteric hip fractures
    Peyser, A
    Weil, Y
    Brocke, L
    Manor, O
    Mosheiff, R
    Liebergall, M
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (11): : 1343 - 1349
  • [44] UNSTABLE INTERTROCHANTERIC FRACTURES OF THE HIP - TREATMENT WITH ENDER PINS COMPARED WITH A COMPRESSION HIP-SCREW
    SERNBO, I
    JOHNELL, O
    GENTZ, CF
    NILSSON, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (09): : 1297 - 1303
  • [45] Reduction in blood loss with tranexamic acid in dynamic hip screw surgery for intertrochanteric hip fractures
    Ahmed, Masroor
    Hussain, Ghulam
    Kumar, Mukesh
    Hamid, Rukhsana
    Nida
    RAWAL MEDICAL JOURNAL, 2019, 44 (01): : 79 - 82
  • [46] The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: A review of 93 cases
    Crawford, CH
    Malkani, AL
    Cordray, S
    Roberts, CS
    Sligar, W
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (02): : 325 - 328
  • [47] Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods
    Yih-Shiunn Lee
    Hui-Ling Huang
    Ting-Ying Lo
    Chien-Rae Huang
    International Orthopaedics, 2007, 31 : 683 - 688
  • [48] Fixation of Intertrochanteric Fractures: Dynamic Hip Screw versus Locking Compression Plate
    Mardani-Kivi, Mohsen
    Mirbolook, Ahmadreza
    Jahromi, Sina Khajeh
    Rad, Melina Rouhi
    TRAUMA MONTHLY, 2013, 18 (02) : 67 - 70
  • [49] Minimally Invasive Dynamic Hip Screw Fixation in Stable and Unstable Intertrochanteric Fractures
    Jana, Kanailal
    Jha, Dipak Kumar
    Chakraburtty, Tapas
    Mullick, Sunny Kumar
    Duttagupta, Swarnava
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (07) : 71 - 74
  • [50] TREATMENT OF UNSTABLE INTERTROCHANTERIC FRACTURES WITH ANATOMIC REDUCTION AND COMPRESSION HIP SCREW FIXATION
    RAO, JP
    BANZON, MT
    WEISS, AB
    RAYHACK, J