Reliability of Predictors for Screw Cutout in Intertrochanteric Hip Fractures

被引:136
|
作者
De Bruijn, Kirstin [1 ]
den Hartog, Dennis
Tuinebreijer, Wim
Roukema, Gert
机构
[1] Univ Med Ctr Rotterdam, Erasmus MC, Dept Surg, NL-3000 CA Rotterdam, Netherlands
来源
关键词
TIP-APEX DISTANCE; FIXATION; FAILURE; FEMUR; NAIL;
D O I
10.2106/JBJS.K.00357
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Following internal fixation of intertrochanteric hip fractures, tip apex distance, fracture classification, position of the screw in the femoral head, and fracture reduction are known predictors for screw cutout, but the reliability of these measurements is unknown. We investigated the reliability of the tip apex distance measurement, the Cleveland femoral head dividing system, the three-grade classification system of Baumgaertner for fracture reduction, and the AO classification system as predictors for screw cutout. Methods: All patients with an intertrochanteric hip fracture who were managed with either a dynamic hip screw or a gamma nail between January 2007 and June 2010 were evaluated from our hip trauma database. Results: The tip apex distance measurement was reliable and patients with device cutout had a significantly higher tip apex distance. The agreement between observers with regard to screw position and fracture reduction was moderately reliable. After adjustment for tip apex distance and screw position, A3 fractures were at more risk of cutout compared with A1 fractures. Poor fracture reduction was significantly related with a higher incidence of cutout in univariate analysis, but not in multivariate analysis. Central-inferior and anterior-inferior positions, after adjustment for tip apex distance and screw position, were significantly protective against cutout. Conclusion: To decrease probable risks of cutout, the tip apex distance needs to stay small or the screw needs to be placed central-inferiorly or anterior-inferiorly. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
引用
收藏
页码:1266 / 1272
页数:7
相关论文
共 50 条
  • [21] Anterior Malreduction is Associated With Lag Screw Cutout After Internal Fixation of Intertrochanteric Fractures
    Inui, Takahiro
    Watanabe, Yoshinobu
    Suzuki, Takashi
    Matsui, Kentaro
    Kurata, Yoshiaki
    Ishii, Keisuke
    Kurozumi, Taketo
    Kawano, Hirotaka
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2024, 482 (03) : 536 - 545
  • [22] Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    Harrington, P
    Nihal, A
    Singhania, AK
    Howell, FR
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01): : 23 - 28
  • [23] Importance of screw position in intertrochanteric femoral fractures treated by dynamic hip screw
    Guven, M.
    Yavuz, U.
    Kadioglu, B.
    Akman, B.
    Kilincoglu, V.
    Unay, K.
    Altintas, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (01) : 20 - 26
  • [24] BIOMECHANICAL ANALYSIS OF THE DYNAMIC HIP SCREW IN THE TREATMENT OF INTERTROCHANTERIC FRACTURES
    WU, CC
    SHIH, CH
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1991, 110 (06) : 307 - 310
  • [25] Salvage of failed dynamic hip screw fixation of intertrochanteric fractures
    Taheriazam, Afshin
    Saeidinia, Amin
    ORTHOPEDIC RESEARCH AND REVIEWS, 2019, 11 : 93 - 98
  • [26] Salvage of failed dynamic hip screw fixation of intertrochanteric fractures
    Said, GZ
    Farouk, O
    El-Sayed, A
    Said, HG
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (02): : 194 - 202
  • [27] A REVIEW OF 100 INTERTROCHANTERIC FRACTURES TREATED WITH THE SLIDING HIP SCREW
    DEKLERK, AJ
    DEBEER, JF
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03): : 506 - 506
  • [28] External fixation of select intertrochanteric fractures with single hip screw
    Christodoulou, NA
    Sdrenias, CV
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (381) : 204 - 211
  • [29] Surgical treatment of intertrochanteric hip fractures with associated femoral neck fractures using a sliding hip screw
    Kyle, RF
    Ellis, TJ
    Templeman, DC
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (01) : 1 - 4
  • [30] Compression hip screw nail-plate system for intertrochanteric fractures
    Maniscalco, P
    Rivera, F
    Bertone, C
    Urgelli, S
    Bocchi, L
    PANMINERVA MEDICA, 2002, 44 (02) : 135 - 139