Intraoperative radiofrequency ablation using a loop internally cooled-perfusion electrode:: In vitro and in vivo experiments

被引:3
|
作者
Lee, JM
Han, JK
Eoh, H
Kim, SH
Lee, JY
Lee, MW
Choi, BI
机构
[1] Seoul Natl Univ Hosp, Dept Diagnost Radiol, Clin Res Inst, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
关键词
liver; interventional procedures; radio-frequency ablation; experimental study;
D O I
10.1016/j.jss.2005.11.584
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective. We sought to validate the efficiency of intraoperative radiofrequency ablation (RFA) using a prototype loop internally cooled-perfusion (LICP) electrode to induce coagulation in the subcapsular portion of the liver. Materials and methods. In in vitro experiments, 30 ablation regions were created using a 200-W generator and a LICP electrode featured simultaneous intraelectrode cooling and continuous flow of hypertonic saline along the shaft in explanted bovine liver. In the in vivo experiments, 26 ablation zones were created according to one of the five protocols in 10 dogs: group A, RFA using a cooled-tip electrode (n = 6); group B, RFA using a LICP electrode with 2 cm loop tip (n = 6); group C, RFA using a LICP electrode with a 3-cm loop tip (n = 6); group D, RFA using a cooled-tip electrode and Pringle maneuver (n = 4); and group E, RFA using a LICP electrode with 2 cm loop tip and Pringle maneuver (n = 4). The dimensions of the coagulation parameters were compared between the groups. Results. In the in vitro experiments, RFA using a 2- or 3-cm diameter LICP electrode (3.6 +/- 0.3 cm, 3.4 +/- 0.5 cm, respectively) created deeper dimensions of coagulation than did a 4-cm electrode (2.3 +/- 0.2 cm; P < 0.05). In the in vivo experiments, the RITA using the LICP electrodes in porcine liver with normal perfusion induced wider but superficial ablation regions when compared to standard RFA using an internally cooled electrode (P < 0.05). However, using a Pringle maneuver, RFA with a LICP electrode created a larger volume of ablation area when compared to RFA using an internally cooled electrode with a similar range of axial diameter along the electrode axis: 30.0 +/- 6.1 cm(3) (group E; P < 0.05) (group D) versus 68.5 +/- 14.0 cm(3) Conclusions. Intraoperative RFA using the LICP electrode induced a well-defined semicircular coagulation with a 3.5-cm axial diameter in the subcapsular region of the liver. This device appears to be promising for the treatment of superficial tumors during intraoperative RFA. (C) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [31] Percutaneous Radiofrequency Ablation Using Internally Cooled Wet Electrodes for the Treatment of Hepatocellular Carcinoma
    Kim, Jin Hyoung
    Kim, Pyo Nyun
    Won, Hyung Jin
    Shin, Yong Moon
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) : 471 - 476
  • [32] Comparison of microwave ablation and multipolar radiofrequency ablation, both using a pair of internally cooled interstitial applicators: Results in ex vivo porcine livers
    Li, Xin
    Zhang, Liang
    Fan, Weijun
    Zhao, Ming
    Wang, Ligang
    Tang, Tian
    Jiang, Hua
    Zhang, Jianlei
    Liu, Yanfeng
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2011, 27 (03) : 240 - 248
  • [33] Radiofrequency liver tissue ablation with a "cooled-wet" electrode: In vivo results in the swine
    Ni, Y
    Miao, Y
    Vaninbroukx, J
    Dymarkowski, S
    Yu, J
    Marchal, GJ
    RADIOLOGY, 2000, 217 : 229 - 229
  • [34] Thermal effect of percutaneous radiofrequency ablation with a clustered electrode for vertebral tumors: In vitro and vivo experiments and clinical application
    Zhao Wei
    Peng Zhao-Hong
    Chen Jin-Zhou
    Hu Ji-Hong
    Huang Jian-Qiang
    Jiang Yong-Neng
    Luo Gang
    Yi Gen-Fa
    Wang Hui
    Jin Shen
    Gao Bu-Lang
    JOURNAL OF BONE ONCOLOGY, 2018, 12 : 69 - 77
  • [35] DEVELOPMENT OF A NEW INTRAOPERATIVE RADIOFREQUENCY ABLATION TECHNIQUE USING A NEEDLE ELECTRODE
    OHTAKE, H
    MISAKI, T
    MATSUNAGA, Y
    WATANABE, G
    TAKAHASHI, M
    MATSUMOTO, I
    KAWASUJI, M
    WATANABE, Y
    ANNALS OF THORACIC SURGERY, 1994, 58 (03): : 750 - 753
  • [36] Percutaneous radiofrequency ablation using internally cooled wet electrodes for the treatment of patients with lung tumors
    Iezzi, R.
    Larici, A. R.
    Posa, A.
    Carchesio, F.
    Congedo, M. T.
    Tagliaferri, L.
    Cassano, A.
    D'argento, E.
    Mantini, G.
    Rodolfino, E.
    Margaritora, S.
    Bria, E.
    Tortora, G.
    Valentini, V.
    Manfredi, R.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2019, 23 (15) : 6554 - 6561
  • [37] Percutaneous radiofrequency ablation using internally cooled wet electrodes for treatment of colorectal liver metastases
    Yoon, H. M.
    Kim, J. H.
    Shin, Y. M.
    Won, H. J.
    Kim, P. N.
    CLINICAL RADIOLOGY, 2012, 67 (02) : 122 - 127
  • [38] An ex-vivo experimental study on optimization of bipolar radiofrequency liver ablation using perfusion-cooled electrodes
    Lee, JM
    Han, JK
    Kim, SH
    Lee, JY
    Shin, KS
    Choi, BI
    ACTA RADIOLOGICA, 2005, 46 (05) : 443 - 451
  • [39] Multipolar radiofrequency ablation with internally cooled electrodes:: Experimental study in ex vivo bovine liver with mathernatic modeling
    Clasen, S
    Schmidt, D
    Boss, A
    Dietz, K
    Kröber, SM
    Claussen, CD
    Pereira, PL
    RADIOLOGY, 2006, 238 (03) : 881 - 890
  • [40] Bipolar Radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver -: Prediction of coagulation volume from applied energy
    Clasen, Stephan
    Schmidt, Diethard
    Dietz, Klaus
    Boss, Andreas
    Kroeber, Stefan M.
    Schraml, Christina
    Fritz, Jan
    Claussen, Claus D.
    Pereira, Philippe L.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (01) : 29 - 36