Intraoperative radiofrequency ablation using a loop internally cooled-perfusion electrode:: In vitro and in vivo experiments

被引:3
|
作者
Lee, JM
Han, JK
Eoh, H
Kim, SH
Lee, JY
Lee, MW
Choi, BI
机构
[1] Seoul Natl Univ Hosp, Dept Diagnost Radiol, Clin Res Inst, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
关键词
liver; interventional procedures; radio-frequency ablation; experimental study;
D O I
10.1016/j.jss.2005.11.584
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective. We sought to validate the efficiency of intraoperative radiofrequency ablation (RFA) using a prototype loop internally cooled-perfusion (LICP) electrode to induce coagulation in the subcapsular portion of the liver. Materials and methods. In in vitro experiments, 30 ablation regions were created using a 200-W generator and a LICP electrode featured simultaneous intraelectrode cooling and continuous flow of hypertonic saline along the shaft in explanted bovine liver. In the in vivo experiments, 26 ablation zones were created according to one of the five protocols in 10 dogs: group A, RFA using a cooled-tip electrode (n = 6); group B, RFA using a LICP electrode with 2 cm loop tip (n = 6); group C, RFA using a LICP electrode with a 3-cm loop tip (n = 6); group D, RFA using a cooled-tip electrode and Pringle maneuver (n = 4); and group E, RFA using a LICP electrode with 2 cm loop tip and Pringle maneuver (n = 4). The dimensions of the coagulation parameters were compared between the groups. Results. In the in vitro experiments, RFA using a 2- or 3-cm diameter LICP electrode (3.6 +/- 0.3 cm, 3.4 +/- 0.5 cm, respectively) created deeper dimensions of coagulation than did a 4-cm electrode (2.3 +/- 0.2 cm; P < 0.05). In the in vivo experiments, the RITA using the LICP electrodes in porcine liver with normal perfusion induced wider but superficial ablation regions when compared to standard RFA using an internally cooled electrode (P < 0.05). However, using a Pringle maneuver, RFA with a LICP electrode created a larger volume of ablation area when compared to RFA using an internally cooled electrode with a similar range of axial diameter along the electrode axis: 30.0 +/- 6.1 cm(3) (group E; P < 0.05) (group D) versus 68.5 +/- 14.0 cm(3) Conclusions. Intraoperative RFA using the LICP electrode induced a well-defined semicircular coagulation with a 3.5-cm axial diameter in the subcapsular region of the liver. This device appears to be promising for the treatment of superficial tumors during intraoperative RFA. (C) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [21] Radiofrequency ablation using injectable cooled electrode: the effects of lidocaine injection in ex vivo study
    Park, Sun-Young
    Chung, Hye Won
    Baek, Jung Hwan
    Lee, Jeong Hyun
    Lee, Min Hee
    Lee, Joon Woo
    ACTA RADIOLOGICA, 2020, 61 (02) : 219 - 226
  • [22] A clinically-oriented computer model for radiofrequency hepatic ablation with internally cooled wet electrode
    Ewertowska, E.
    Quesada, R.
    Radosevic, A.
    Andaluz, A.
    Moll, X.
    Berjano, E.
    Burdio, F.
    Trujillo, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (05) : 479 - 479
  • [23] A clinically oriented computer model for radiofrequency ablation of hepatic tissue with internally cooled wet electrode
    Ewertowska, E.
    Quesada, R.
    Radosevic, A.
    Andaluz, A.
    Moll, X.
    Garcia Arnas, F.
    Berjano, E.
    Burdio, F.
    Trujillo, M.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 194 - 204
  • [24] Internally gas-cooled radiofrequency applicators as an alternative to conventional radiofrequency and microwave ablation devices: An in vivo comparison
    Rempp, Hansjoeg
    Voigtlaender, Matthias
    Schenk, Martin
    Enderle, Markus D.
    Scharpf, Marcus
    Greiner, Tim O.
    Neugebauer, Alexander
    Hoffmann, Ruediger
    Claussen, Claus D.
    Clasen, Stephan
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : E350 - E355
  • [25] A comparison of microwave ablation and bipolar radiofrequency ablation both with an internally cooled probe: Results in ex vivo and in vivo porcine livers
    Yu, Jie
    Liang, Ping
    Yu, Xiaoling
    Liu, Fangyi
    Chen, Lei
    Wang, Yang
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (01) : 124 - 130
  • [26] Effects of parameters on radiofrequency guidewire ablation: In vitro and in vivo experiments
    Zuo, Zhongyin
    Li, Sainan
    Xuan, Fengqi
    Zhang, Jie
    Liu, Zichen
    Zhang, Shibei
    Liang, Ming
    Wang, Zulu
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (12) : 2535 - 2544
  • [27] Radiofrequency hepatic ablation with internally cooled electrodes and hybrid applicators with distant saline infusion using an in vivo porcine model
    Burdio, F.
    Navarro, A.
    Berjano, E. J.
    Burdio, J. M.
    Gonzalez, A.
    Guemes, A.
    Sousa, R.
    Rufas, M.
    Cruz, I.
    Castiella, T.
    Lozano, R.
    Lequerica, J. L.
    Grande, L.
    EJSO, 2008, 34 (07): : 822 - 830
  • [28] Switching monopolar radiofrequency ablation technique using multiple, internally cooled electrodes and a multichannel generator - Ex vivo and in vivo pilot study
    Lee, Jeong Min
    Han, Joon Koo
    Kim, Hyo Cheol
    Choi, Young Hun
    Kim, Se Hyung
    Choi, Jin Young
    Choi, Byung Ihn
    INVESTIGATIVE RADIOLOGY, 2007, 42 (03) : 163 - 171
  • [29] Image-guided percutaneous radiofrequency ablation of unresectable spinal metastases with an internally cooled electrode system
    Gevargez, A
    Braun, M
    Schirp, S
    Groenemeyer, DH
    RADIOLOGY, 2002, 225 : 614 - 614
  • [30] Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation
    Park, Mi-Hyun
    Cho, June-Sik
    Shin, Byung Seok
    Jeon, Gyeong Sik
    Lee, Byungmo
    Lee, Kichang
    GUT AND LIVER, 2012, 6 (04) : 471 - 475