HbA1c response and hospital admissions following commencement of flash glucose monitoring in adults with type 1 diabetes

被引:11
|
作者
Stimson, Roland H. [1 ]
Dover, Anna R. [2 ]
Ritchie, Stuart A. [3 ]
Wright, Rohana J. [4 ]
McKnight, John A. [3 ]
Zammitt, Nicola N. [2 ]
Gibb, Fraser W. [1 ,2 ]
机构
[1] Univ Edinburgh, Queens Med Res Inst, Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
[2] Royal Infirm Edinburgh NHS Trust, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
[3] Western Gen Hosp, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
[4] NHS Lothian, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
关键词
A1c; continous blood glucose monitor(s); hypoglycemia; ketoacidosis; QUALITY-OF-LIFE; GLYCEMIC CONTROL; SEVERE HYPOGLYCEMIA; PEOPLE;
D O I
10.1136/bmjdrc-2020-001292
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Our aim was to assess the effect of introducing flash monitoring in adults with type 1 diabetes with respect to change in hemoglobin A1c (HbA1c) and frequency of hospital admissions. Research design and methods Prospective observational study of adults with type 1 diabetes in our center, in whom a prescription for a flash monitoring sensor was collected. Primary outcome was change in HbA1c between 2016 and after flash monitoring. Rates of hospital admission were compared between the first year after flash monitoring and the corresponding 12-month period 2 years earlier. Results Approximately half of all adults with type 1 diabetes, attending our center, collected prescriptions for flash monitoring sensors (n=2216). Median fall in HbA1c was -1 (-0.1) mmol/mol (%) (p<0.001) and was greatest in those with baseline HbA1c >75 (9.0) mmol/mol (%): -10 (-0.9) mmol/mol (%), p53 mmol/mol (7%) experienced a >= 5 mmol/mol (0.5%) fall in HbA1c. In addition to higher HbA1c, early commencement within 1 month of NHS-funded flash monitoring (p<0.001), and male gender (p=0.013) were associated with a fall in HbA1c of >= 5 (0.5) mmol/mol (%). Socioeconomic deprivation (p=0.009) and collecting fewer than 2 sensors per month (p=0.002) were associated with lack of response. Overall, hospital admissions did not change but an increase in admissions for hypoglycemia was observed (1.1% vs 0.3%, p=0.026). Conclusions Flash monitoring is associated with reduction in HbA1c in individuals with HbA1c >58 mmol/mol. Numerous clinical features are independently associated with HbA1c response. An increase in hypoglycemia admissions occurred following flash monitoring.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The importance of HbA1c and glucose variability in patients with type 1 and type 2 diabetes: outcome of continuous glucose monitoring (CGM)
    Sartore, Giovanni
    Chilelli, Nino Cristiano
    Burlina, Silvia
    Di Stefano, Paola
    Piarulli, Francesco
    Fedele, Domenico
    Mosca, Andrea
    Lapolla, Annunziata
    ACTA DIABETOLOGICA, 2012, 49 : S153 - S160
  • [22] The importance of HbA1c and glucose variability in patients with type 1 and type 2 diabetes: outcome of continuous glucose monitoring (CGM)
    Giovanni Sartore
    Nino Cristiano Chilelli
    Silvia Burlina
    Paola Di Stefano
    Francesco Piarulli
    Domenico Fedele
    Andrea Mosca
    Annunziata Lapolla
    Acta Diabetologica, 2012, 49 : 153 - 160
  • [23] Improving HbA1c Control in Type 1 or Type 2 Diabetes Using Flash Glucose Monitoring: A Retrospective Observational Analysis in Two German Centres
    Ludger Rose
    Gerhard Klausmann
    Alexander Seibold
    Diabetes Therapy, 2021, 12 : 363 - 372
  • [24] Improving HbA1c Control in Type 1 or Type 2 Diabetes Using Flash Glucose Monitoring: A Retrospective Observational Analysis in Two German Centres
    Rose, Ludger
    Klausmann, Gerhard
    Seibold, Alexander
    DIABETES THERAPY, 2021, 12 (01) : 363 - 372
  • [25] HbA1c and the Prediction of Type 2 Diabetes in Children and Adults
    Vijayakumar, Pavithra
    Nelson, Robert G.
    Hanson, Robert L.
    Knowler, William C.
    Sinha, Madhumita
    DIABETES CARE, 2017, 40 (01) : 16 - 21
  • [26] Continuous glucose monitoring and HbA1c in the evaluation of glucose metabolism in children at high risk for type 1 diabetes mellitus
    Helminen, Olli
    Pokka, Tytti
    Tossavainen, Paivi
    Ilonen, Jorma
    Knip, Mikael
    Veijola, Riitta
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 120 : 89 - 96
  • [27] Accuracy of glucose sensor estimate of HbA1c in children with type 1 diabetes
    Ehtisham, Sarah
    Adhami, Sara
    HORMONE RESEARCH IN PAEDIATRICS, 2019, 91 : 87 - 87
  • [28] Review: Continuous glucose monitoring reduces HbA1c more than self-monitoring in type 1 diabetes
    Burden, A. C. Felix
    ANNALS OF INTERNAL MEDICINE, 2013, 158 (06)
  • [29] The effect of deprivation and HbA1c on hyperglycaemic admission to hospital in type 1 diabetes
    Govan, L.
    DIABETOLOGIA, 2011, 54 : S386 - S386
  • [30] HbA1c and blood glucose for the diagnosis of diabetes
    Misra, Anoop
    Garg, Satish
    LANCET, 2011, 378 (9786): : 104 - 106