HbA1c response and hospital admissions following commencement of flash glucose monitoring in adults with type 1 diabetes

被引:11
|
作者
Stimson, Roland H. [1 ]
Dover, Anna R. [2 ]
Ritchie, Stuart A. [3 ]
Wright, Rohana J. [4 ]
McKnight, John A. [3 ]
Zammitt, Nicola N. [2 ]
Gibb, Fraser W. [1 ,2 ]
机构
[1] Univ Edinburgh, Queens Med Res Inst, Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
[2] Royal Infirm Edinburgh NHS Trust, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
[3] Western Gen Hosp, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
[4] NHS Lothian, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
关键词
A1c; continous blood glucose monitor(s); hypoglycemia; ketoacidosis; QUALITY-OF-LIFE; GLYCEMIC CONTROL; SEVERE HYPOGLYCEMIA; PEOPLE;
D O I
10.1136/bmjdrc-2020-001292
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Our aim was to assess the effect of introducing flash monitoring in adults with type 1 diabetes with respect to change in hemoglobin A1c (HbA1c) and frequency of hospital admissions. Research design and methods Prospective observational study of adults with type 1 diabetes in our center, in whom a prescription for a flash monitoring sensor was collected. Primary outcome was change in HbA1c between 2016 and after flash monitoring. Rates of hospital admission were compared between the first year after flash monitoring and the corresponding 12-month period 2 years earlier. Results Approximately half of all adults with type 1 diabetes, attending our center, collected prescriptions for flash monitoring sensors (n=2216). Median fall in HbA1c was -1 (-0.1) mmol/mol (%) (p<0.001) and was greatest in those with baseline HbA1c >75 (9.0) mmol/mol (%): -10 (-0.9) mmol/mol (%), p53 mmol/mol (7%) experienced a >= 5 mmol/mol (0.5%) fall in HbA1c. In addition to higher HbA1c, early commencement within 1 month of NHS-funded flash monitoring (p<0.001), and male gender (p=0.013) were associated with a fall in HbA1c of >= 5 (0.5) mmol/mol (%). Socioeconomic deprivation (p=0.009) and collecting fewer than 2 sensors per month (p=0.002) were associated with lack of response. Overall, hospital admissions did not change but an increase in admissions for hypoglycemia was observed (1.1% vs 0.3%, p=0.026). Conclusions Flash monitoring is associated with reduction in HbA1c in individuals with HbA1c >58 mmol/mol. Numerous clinical features are independently associated with HbA1c response. An increase in hypoglycemia admissions occurred following flash monitoring.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Flash monitoring online educational quiz is associated with lower HbA1c in people with Type 1 diabetes
    Gibb, F.
    Wilmot, E.
    Stimson, R.
    Dover, A.
    DIABETIC MEDICINE, 2019, 36 : 105 - 105
  • [12] Improvement in HbA1c after Flash Monitoring Is Not Associated with Risk of Retinopathy Progression in Type 1 Diabetes
    Linton, Kathryn
    Gibb, Fraser W.
    DIABETES, 2020, 69
  • [13] HbA1c or glucose for diabetes diagnosis?
    Florkowski, CM
    Woltersdorf, WWW
    ANNALS OF CLINICAL BIOCHEMISTRY, 2005, 42 : 408 - 409
  • [14] HbA1c or glucose for diabetes diagnosis?
    Kilpatrick, ES
    ANNALS OF CLINICAL BIOCHEMISTRY, 2005, 42 : 165 - 166
  • [15] HbA1c Is Disproportionately Higher in Women and Older People With Type 1 Diabetes Compared With Flash Glucose Monitoring Metrics of Glycemic Control
    Stimson, Roland H.
    Dover, Anna R.
    Forbes, Shareen
    Strachan, Mark W. J.
    McKnight, John A.
    Gibb, Fraser W.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (02): : 446 - 453
  • [16] HbA1c levels and hospital admission in people with type 1 diabetes
    Govan, L.
    DIABETOLOGIA, 2010, 53 : S97 - S97
  • [17] Relationship of baseline HbA1c and HbA1c reduction following insulin therapy in Type 2 diabetes
    Giugliano, D.
    Esposito, K.
    DIABETIC MEDICINE, 2011, 28 (02) : 247 - 247
  • [18] HbA1c Monitoring among Adolescents and Young Adults with Type 1 Diabetes: Impact of Diabetes Care Provider Type
    Wisk, Lauren E.
    Landrum, Mary Beth
    Fu, Christina
    Chien, Alyna
    DIABETES, 2021, 70
  • [19] Can HbA1c detect undiagnosed diabetes in acute medical hospital admissions?
    Manley, Susan E.
    O'Brien, Kathleen T.
    Quinlan, Diarmuid
    Round, Rachel A.
    Nightingale, Peter G.
    Ali, Fauzi
    Durrani, Behram K.
    Liew, Aaron
    Luzio, Stephen D.
    Stratton, Irene M.
    Roberts, Graham A.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2016, 115 : 106 - 114
  • [20] The interrelationship of HbA1c and real-time continuous glucose monitoring in children with type 1 diabetes
    Ferenci, Tamas
    Koerner, Anna
    Kovacs, Levente
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 108 (01) : 38 - 44