HbA1c response and hospital admissions following commencement of flash glucose monitoring in adults with type 1 diabetes

被引:11
|
作者
Stimson, Roland H. [1 ]
Dover, Anna R. [2 ]
Ritchie, Stuart A. [3 ]
Wright, Rohana J. [4 ]
McKnight, John A. [3 ]
Zammitt, Nicola N. [2 ]
Gibb, Fraser W. [1 ,2 ]
机构
[1] Univ Edinburgh, Queens Med Res Inst, Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
[2] Royal Infirm Edinburgh NHS Trust, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
[3] Western Gen Hosp, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
[4] NHS Lothian, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Midlothian, Scotland
关键词
A1c; continous blood glucose monitor(s); hypoglycemia; ketoacidosis; QUALITY-OF-LIFE; GLYCEMIC CONTROL; SEVERE HYPOGLYCEMIA; PEOPLE;
D O I
10.1136/bmjdrc-2020-001292
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Our aim was to assess the effect of introducing flash monitoring in adults with type 1 diabetes with respect to change in hemoglobin A1c (HbA1c) and frequency of hospital admissions. Research design and methods Prospective observational study of adults with type 1 diabetes in our center, in whom a prescription for a flash monitoring sensor was collected. Primary outcome was change in HbA1c between 2016 and after flash monitoring. Rates of hospital admission were compared between the first year after flash monitoring and the corresponding 12-month period 2 years earlier. Results Approximately half of all adults with type 1 diabetes, attending our center, collected prescriptions for flash monitoring sensors (n=2216). Median fall in HbA1c was -1 (-0.1) mmol/mol (%) (p<0.001) and was greatest in those with baseline HbA1c >75 (9.0) mmol/mol (%): -10 (-0.9) mmol/mol (%), p53 mmol/mol (7%) experienced a >= 5 mmol/mol (0.5%) fall in HbA1c. In addition to higher HbA1c, early commencement within 1 month of NHS-funded flash monitoring (p<0.001), and male gender (p=0.013) were associated with a fall in HbA1c of >= 5 (0.5) mmol/mol (%). Socioeconomic deprivation (p=0.009) and collecting fewer than 2 sensors per month (p=0.002) were associated with lack of response. Overall, hospital admissions did not change but an increase in admissions for hypoglycemia was observed (1.1% vs 0.3%, p=0.026). Conclusions Flash monitoring is associated with reduction in HbA1c in individuals with HbA1c >58 mmol/mol. Numerous clinical features are independently associated with HbA1c response. An increase in hypoglycemia admissions occurred following flash monitoring.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] HbA1c response and hospital admissions following commencement of flash glucose monitoring in adults with type 1 diabetes
    Gibb, F. W.
    Dover, A. R.
    Ritchie, S. A.
    Wright, R. J.
    McKnight, J. A.
    Zammitt, N. N.
    Stimson, R. H.
    DIABETIC MEDICINE, 2020, 37 : 146 - 147
  • [2] Marked improvement in HbA1c following commencement of flash glucose monitoring in type 1 diabetes
    Dover, A. R.
    Stimson, R. H.
    Tyndall, V.
    McKnight, J. A.
    Ritchie, S. A.
    Zammitt, N. N.
    Gibb, F. W.
    DIABETOLOGIA, 2019, 62 : S433 - S433
  • [3] Striking Improvements in HbA1c following Commencement of Flash Glucose Monitoring in Type 1 Diabetes
    Gibb, Fraser W.
    Stimson, Roland H.
    Mcknight, John A.
    Tyndall, Victoria
    Ritchie, Stuart A.
    Zammitt, Nicola N.
    Dover, Anna R.
    DIABETES, 2019, 68
  • [4] Marked improvement in HbA1c following commencement of flash glucose monitoring in people with type 1 diabetes
    Victoria Tyndall
    Roland H. Stimson
    Nicola N. Zammitt
    Stuart A. Ritchie
    John A. McKnight
    Anna R. Dover
    Fraser W. Gibb
    Diabetologia, 2019, 62 : 1349 - 1356
  • [5] Marked improvement in HbA1c following commencement of flash glucose monitoring in people with type 1 diabetes
    Tyndall, Victoria
    Stimson, Roland H.
    Zammitt, Nicola N.
    Ritchie, Stuart A.
    McKnight, John A.
    Dover, Anna R.
    Gibb, Fraser W.
    DIABETOLOGIA, 2019, 62 (08) : 1349 - 1356
  • [6] Flash glucose monitoring improves HbA1c in people with type 1 diabetes
    Harte, R.
    Connelly, P.
    Drummond, R.
    Carty, D.
    Osborne, L.
    Cleland, S.
    Kennon, B.
    Hopkinson, H.
    Smith, C.
    Boyle, J. G.
    DIABETIC MEDICINE, 2020, 37 : 147 - 147
  • [7] RELATIONSHIP BETWEEN HBA1C AND ESTIMATED HBA1C IN PATIENTS WITH TYPE 1 DIABETES USING FLASH GLUCOSE MONITORING
    Charleer, S.
    De Block, C.
    Nobels, F.
    Mathieu, C.
    Gillard, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A23 - A23
  • [8] HbA1c reduction following flash monitoring commencement is not independently associated with adverse diabetic eye disease outcomes in type 1 diabetes
    Al-Dalla Ali, Muhammad
    Stimson, Roland H.
    Dover, Anna R.
    Forbes, Shareen
    Annoh, Roxanne
    Madill, Karen
    Gibb, Fraser W.
    BMJ OPEN DIABETES RESEARCH & CARE, 2020, 8 (02)
  • [9] Admission Plasma Glucose and HbA1c in Emergency Hospital Admissions by Ethnicity
    Manley, Susan E.
    Susarla, Radhika
    Round, Rachel A.
    Nightingale, Peter
    Williams, John A.
    Stratton, Irene M.
    Webber, Jonathan
    Gkoutos, Georgios
    Hanif, Wasim
    Roberts, Graham
    Ghosh, Sandip
    DIABETES, 2019, 68
  • [10] The Associations of Mean Glucose and Time in Range from Continuous Glucose Monitoring with HbA1c in Adults with Type 2 Diabetes
    Selvin, Elizabeth
    Wang, Dan
    Rooney, Mary R.
    Echouffo-Tcheugui, Justin
    Fang, Michael
    Zeger, Scott
    Sartini, Joseph
    Tang, Olive
    Coresh, Josef
    Aurora, R. Nisha
    Punjabi, Naresh M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (01) : 86 - 90