Improving Fault Recovery Performance of an HVDC Link with a Weak Receiving AC System by Optimization of DC Controls

被引:0
|
作者
Chao, Hong [1 ]
机构
[1] China Southern Power Grid Co Ltd, Elect Power Res Inst, Power Syst Res Dept, Guangzhou, Guangdong, Peoples R China
关键词
electromagnetic transient simulation; fault recovery; HVDC controls; weak AC systems;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A problem associated with an HVDC link feeding into a weak AC system is the poor fault recovery performance from commutation failures caused by inverter AC system faults, especially when the receiving AC system is further weakened due to faults clearing. To obtain acceptable recovery performance, the pre-fault DC power transfer capability may have to be limited below the rated DC power. Based on electromagnetic transient simulations, the available power transfer capability of an actual HVDC system is evaluated by considering fault recovery performance of the AC/DC system under specified receiving AC system faults. To increase the available power transfer capability, the optimization of HVDC controls is implemented aiming at obtaining acceptable recovery performance. Simulation results show that the optimized HVDC controls can help to improve fault recovery performance and hence obviously increase the DC power transfer capability.
引用
收藏
页码:4474 / 4479
页数:6
相关论文
共 50 条
  • [21] AC and DC Fault Ride-Through Strategies for Hybrid MMC Based HVDC Link and Interaction With Multimachine Power System Dynamics
    Bandaru, Teja
    Bhattacharya, Tanmoy
    Chatterjee, Dheeman
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (04) : 5790 - 5802
  • [22] A VSC-HVDC Fuzzy Controller for Improving the Stability of AC/DC Power System
    Li, Sheng
    Zhang, Jianhua
    Shang, Jingfu
    Wu, Ziping
    Zhou, Mingxia
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2059 - 2063
  • [23] An enhanced MMC-HVDC topology and system recovery strategy for DC fault protection
    Wang, Yi
    Liu, Jianzheng
    Dianwang Jishu/Power System Technology, 2015, 39 (08): : 2312 - 2319
  • [24] DC fault characteristic analysis and recovery control strategy for hybrid cascaded HVDC system
    Yang S.
    Zheng A.
    Peng Y.
    Guo C.
    Zhao C.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (09): : 166 - 172and179
  • [25] Analysis of impact of "strong DC and weak AC" on receiving-end power system
    Wang, Qiang
    Li, Tianran
    Yang, Pengcheng
    3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2018, 113
  • [26] Improving frequency stability of parallel AC-DC hybrid systems by power modulation strategy of HVDC link
    Zhu, Hongping
    Luo, Longfu
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2012, 32 (16): : 36 - 43
  • [27] Dynamic performance of HVDC system according to exciter characteristics of synchronous compensator in a weak AC system
    Kim, CK
    Jang, G
    Yang, BM
    ELECTRIC POWER SYSTEMS RESEARCH, 2002, 63 (03) : 203 - 211
  • [28] Dynamic Reactive Compensation Requirements at the Rectifier End of an LCC HVDC Link Connected to a Weak AC System
    ElMehdi, Abosalah
    Momen, Ahmed
    Johnson, Brian K.
    2014 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2014,
  • [29] Influence Analysis of New Energy Proportion in the AC System on DC Fault Current of the MMC-HVDC System
    Liu, Siyuan
    Li, Botong
    Li, Andi
    Li, Bin
    Wen, Weijie
    Ji, Liang
    2023 5TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM, AEEES, 2023, : 527 - 532
  • [30] STABILIZATION OF AN AC-DC POWER SYSTEM USING A CONTROLLED MULTI-TERMINAL HVDC LINK
    RAHMAN, MA
    DASH, PK
    ELECTRIC POWER SYSTEMS RESEARCH, 1981, 4 (02) : 135 - 146