Improving Fault Recovery Performance of an HVDC Link with a Weak Receiving AC System by Optimization of DC Controls

被引:0
|
作者
Chao, Hong [1 ]
机构
[1] China Southern Power Grid Co Ltd, Elect Power Res Inst, Power Syst Res Dept, Guangzhou, Guangdong, Peoples R China
关键词
electromagnetic transient simulation; fault recovery; HVDC controls; weak AC systems;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A problem associated with an HVDC link feeding into a weak AC system is the poor fault recovery performance from commutation failures caused by inverter AC system faults, especially when the receiving AC system is further weakened due to faults clearing. To obtain acceptable recovery performance, the pre-fault DC power transfer capability may have to be limited below the rated DC power. Based on electromagnetic transient simulations, the available power transfer capability of an actual HVDC system is evaluated by considering fault recovery performance of the AC/DC system under specified receiving AC system faults. To increase the available power transfer capability, the optimization of HVDC controls is implemented aiming at obtaining acceptable recovery performance. Simulation results show that the optimized HVDC controls can help to improve fault recovery performance and hence obviously increase the DC power transfer capability.
引用
收藏
页码:4474 / 4479
页数:6
相关论文
共 50 条
  • [11] PROTECTING A HVDC LINK AGAINST ACCIDENTAL ISOLATION FROM ITS RECEIVING AC SYSTEM
    WHITEHOUSE, RS
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1586 - 1590
  • [12] An approach to improving performance of the dc filter in HVDC transmission system
    Li Ming
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, PTS 1 AND 2, 2011, 48-49 : 183 - 186
  • [13] HVDC converter control for fast power recovery after AC system fault
    Sato, M
    Yamaji, K
    Honjo, N
    Yoshino, T
    Arai, J
    IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (03) : 1319 - 1326
  • [14] Characteristics and Recovery Performance of VSC-HVDC DC Transmission Line Fault
    Yang, Jie
    Zheng, Jianchao
    Tang, Guangfu
    He, Zhiyuan
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [15] Effect of the DC control on recovery from commutation failures in an HVDC inverter feeding a weak AC network
    Khatir, Mohamed
    Zidi, Sid-Ahmed
    Hadjeri, Samir
    Fellah, Mohammed-Karim
    Dahou, Omar
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2007, 58 (04): : 200 - 206
  • [16] Study on Mechanism of STATCOM Improving the Transmission Capability of HVDC Connected to Weak AC System
    Yang J.
    Hong C.
    Zhou B.
    Li H.
    Zhang Y.
    Zhang F.
    Li J.
    Sun P.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (17): : 5005 - 5014
  • [17] Performance Evaluation and Reliability of Flexible Asynchronous AC Link and LCC-HVDC Link Under Fault Conditions
    Imdadullah
    Beig, Abdul R.
    Asghar, M. Syed Jamil
    IEEE ACCESS, 2020, 8 : 120562 - 120574
  • [18] Recovery characteristics of new-type HVDC connected to AC system with weak strength
    Li, Ji
    Luo, Long-Fu
    Xu, Jia-Zhu
    Li, Yong
    Zhang, Jie
    Liu, Fu-Sheng
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (10): : 137 - 141
  • [19] Dynamic performance of a STATCON at an HVDC inverter feeding a very weak ac system
    Zhuang, Y
    Menzies, RW
    Nayak, OB
    Turanli, HM
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (02) : 958 - 964
  • [20] Coordination And Optimization Of HVDC Modulations Using Chaotic Optimization Algorithm in DC/AC Power System
    Zheng Xi-yun
    Li Xing-yuan
    Wang Yu-hong
    Xu Mei-mei
    Mu Zi-long
    Liu Jian
    Wei Wei
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,