Radiant cooling of an enclosure

被引:7
|
作者
Chebihi, A
Byun, KH
Wen, J
Smith, TF [1 ]
机构
[1] Univ Iowa, Dept Engn Mech, Iowa City, IA 52242 USA
[2] Fac Univ N Dame Paix, Lab Phys Solide, B-5000 Namur, Belgium
[3] Dongguk Univ, Dept Engn Mech, Seoul 100715, South Korea
[4] Drexel Univ, Dept Civil Architectural & Environm Engn, Philadelphia, PA 19104 USA
[5] Univ Iowa, Dept Engn Mech, Iowa City, IA 52242 USA
关键词
radiant cooling; atmosphere sky window; enclosure; radiative properties;
D O I
10.1016/j.enconman.2005.04.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
The purpose of this study is to analyze the potential for radiant cooling using the atmospheric sky window and to evaluate the desired characteristics of a radiant cooling material (RCM) applied to the ceiling window of a three-dimensional enclosure. The thermal characteristics of the system are governed by the geometry, ambient temperature, sky radiative temperature, amount of solar energy and its direction, heat transfer modes, wall radiative properties, and radiative properties of the RCMs. A semi-gray band analysis is utilized for the solar and infrared bands. The radiosity/irradiation method is used in each band to evaluate the radiant exchanges in the enclosure. The radiative properties for the RCM are varied in a parametric study to identify the desired properties of RCMs. For performance simulation of real RCMs, the radiative properties are calculated from spectral data. The desired solar property is a high reflectance for both opaque and semi-transparent RCMs. For a semi-transparent RCM, a low value of the solar transmittance is preferred. The desired infrared property is a high emittance for an opaque RCM. For a semi-transparent RCM, a high infrared transmittance is desired, and the emittance should be greater than zero. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:229 / 252
页数:24
相关论文
共 50 条
  • [41] Investigation of Multiple Cooling Coil Effect in Hydronic Radiant Cooling System
    Damanhuri, A. A. M.
    Lubis, A. M. H. S.
    Ibrahim, A.
    Kamaruzzaman, K. A.
    Rosli, M. H.
    Pawanteh, M. R.
    PROCEEDINGS OF MECHANICAL ENGINEERING RESEARCH DAY 2017 (MERD), 2017, : 178 - 179
  • [42] Numerical simulation of radiant floor cooling system
    Jin, Xing
    Zhang, Xiaosong
    Cao, Rongquan
    Cao, Yiran
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2010, 31 (06): : 732 - 737
  • [43] THE ANGLE FACTOR FOR RADIANT INTERCHANGE WITHIN A CONSTANT RADIUS CYLINDRICAL ENCLOSURE
    HAHNE, E
    BASSIOUNI, MK
    LETTERS IN HEAT AND MASS TRANSFER, 1980, 7 (04): : 303 - 309
  • [44] METHOD OF EVALUATING SCRIPT-F FOR RADIANT EXCHANGE WITHIN AN ENCLOSURE
    ISHIMOTO, T
    BEVANS, JT
    AIAA JOURNAL, 1963, 1 (06) : 1428 - 1429
  • [45] EFFICIENT COMPUTATION OF RADIANT-INTERCHANGE CONFIGURATION FACTORS WITHIN ENCLOSURE
    SOWELL, EF
    OBRIEN, PF
    JOURNAL OF HEAT TRANSFER, 1972, 94 (03): : 326 - &
  • [46] An Experimental Investigation of the Passive Cooling of a Building Using Nighttime Radiant Cooling
    Okoronkwo, C. A.
    Nwigwe, K. N.
    Ogueke, N. V.
    Anyanwu, E. E.
    Onyejekwe, D. C.
    Ugwuoke, P. E.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2014, 11 (10) : 1072 - 1083
  • [47] Simplified model for radiant heating and cooling panels
    Kilkis, I.B.
    Sager, S.S.
    Uludag, M.
    Simulation Practice and Theory, 1994, 2 (02): : 61 - 76
  • [48] Simulation of Radiant Cooling Systems in Cleanroom Applications
    Al Beltagy, Mohamed
    El Morsi, Mohamed
    El Baz, Ahmed
    El Assy, Ahmed
    ASHRAE JOURNAL, 2019, 61 (11) : 55 - 66
  • [49] A Review on Radiant Cooling System in Buildings of China
    Wang, Hongbin
    Shu, Haiwen
    Lin Duanmu
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 101 - 108
  • [50] Customization of laboratory for radiant cooling ceiling measurements
    Sehnalek, Stanislav
    Kolacek, Martin
    22ND INTERNATIONAL CONFERENCE ON CIRCUITS, SYSTEMS, COMMUNICATIONS AND COMPUTERS (CSCC 2018), 2018, 210