Radiant cooling of an enclosure

被引:7
|
作者
Chebihi, A
Byun, KH
Wen, J
Smith, TF [1 ]
机构
[1] Univ Iowa, Dept Engn Mech, Iowa City, IA 52242 USA
[2] Fac Univ N Dame Paix, Lab Phys Solide, B-5000 Namur, Belgium
[3] Dongguk Univ, Dept Engn Mech, Seoul 100715, South Korea
[4] Drexel Univ, Dept Civil Architectural & Environm Engn, Philadelphia, PA 19104 USA
[5] Univ Iowa, Dept Engn Mech, Iowa City, IA 52242 USA
关键词
radiant cooling; atmosphere sky window; enclosure; radiative properties;
D O I
10.1016/j.enconman.2005.04.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
The purpose of this study is to analyze the potential for radiant cooling using the atmospheric sky window and to evaluate the desired characteristics of a radiant cooling material (RCM) applied to the ceiling window of a three-dimensional enclosure. The thermal characteristics of the system are governed by the geometry, ambient temperature, sky radiative temperature, amount of solar energy and its direction, heat transfer modes, wall radiative properties, and radiative properties of the RCMs. A semi-gray band analysis is utilized for the solar and infrared bands. The radiosity/irradiation method is used in each band to evaluate the radiant exchanges in the enclosure. The radiative properties for the RCM are varied in a parametric study to identify the desired properties of RCMs. For performance simulation of real RCMs, the radiative properties are calculated from spectral data. The desired solar property is a high reflectance for both opaque and semi-transparent RCMs. For a semi-transparent RCM, a low value of the solar transmittance is preferred. The desired infrared property is a high emittance for an opaque RCM. For a semi-transparent RCM, a high infrared transmittance is desired, and the emittance should be greater than zero. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:229 / 252
页数:24
相关论文
共 50 条
  • [21] Numerical Prediction of Mean Radiant Temperature in Radiant Cooling Indoor Environments
    Daoming Xing
    Nianping Li
    Journal of Thermal Science, 2022, 31 : 359 - 369
  • [22] Possibilities and limitations of radiant floor cooling
    Olesen, BW
    ASHRAE TRANSACTIONS 1997, VOL 103, PT I, 1997, 103 : 42 - 48
  • [23] Exergy Metrication of Radiant Heating and Cooling
    Kilkis, Birol
    ASHRAE: TRANSACTIONS 2011, VOL 117, PT 1, 2011, 117 : 64 - 70
  • [24] Research on the radiant ceiling cooling system
    Yan, QQ
    Qi, ZX
    Wang, W
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 971 - 975
  • [25] Discussion on the Network Method for Calculating Radiant Interchange Within an Enclosure
    H.J. Kang
    W.Q. Tao(School of Energy and Power Engineering
    JournalofThermalScience, 1994, (02) : 130 - 135
  • [26] HYDRONIC RADIANT COOLING - PRELIMINARY ASSESSMENT
    FEUSTEL, HE
    STETIU, C
    ENERGY AND BUILDINGS, 1995, 22 (03) : 193 - 205
  • [27] Investigation on the cooling performance of a green roof with a radiant cooling system
    Yeom, Dongwoo
    La Roche, Pablo
    ENERGY AND BUILDINGS, 2017, 149 : 26 - 37
  • [28] Efficiency of Vortex Tube Enclosure Cooling
    Rattanongphisat, Waraporn
    ELECTRONICS, MECHATRONICS AND AUTOMATION III, 2014, 666 : 154 - 158
  • [29] RADIANT COOLING .2. CONE WALL ABSORPTION OF EXTERNAL RADIANT POWER
    ANNABLE, RV
    APPLIED OPTICS, 1972, 11 (07): : 1495 - &
  • [30] Study on radiant heat exchange between human body and radiant surfaces under asymmetric radiant cooling environments
    Deng, Yan
    Ding, Yunfei
    Chen, Sihao
    Li, Jing
    Zhou, Chonggang
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 37