Fracture Resistance of Monolithic Zirconia Crowns in Implant Prostheses in Patients with Bruxism

被引:9
|
作者
Lan, Ting-Hsun [1 ,2 ]
Pan, Chin-Yun [3 ]
Liu, Pao-Hsin [4 ]
Chou, Mitch M. C. [5 ]
机构
[1] Kaohsiung Med Univ Hosp, Dept Dent, Div Prosthodont, Kaohsiung 80708, Taiwan
[2] Kaohsiung Med Univ, Coll Dent Med, Sch Dent, Kaohsiung 80708, Taiwan
[3] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Dent, Div Orthodont, Kaohsiung 80708, Taiwan
[4] I Shou Univ, Dept Biomed Engn, Kaohsiung 82442, Taiwan
[5] Natl Sun Yat Sen Univ, Dept Mat & Optoelect Sci, Kaohsiung 80424, Taiwan
关键词
monolithic zirconia crown; thickness; dental implant prosthesis; cyclic loading; finite element analysis; TOOTH WEAR; FAILURE LOAD; MANAGEMENT; COMPLICATIONS; OCCLUSION; CERAMICS; THERAPY; DESIGN; SLEEP;
D O I
10.3390/ma12101623
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this study is to determine the minimum required thickness of a monolithic zirconia crown in the mandibular posterior area for patients with bruxism. Forty-nine full zirconia crowns, with seven different occlusal thicknesses of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm, were made by using a computer-aided design/computer-aided manufacturing system (CAD/CAM). Seven crowns in each group were subjected to cyclic loading at 800 N and 5 Hz in a servohydraulic testing machine until fracture or completion of 100,000 cycles. Seven finite element models comprising seven different occlusal thicknesses of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm were simulated using three different loads of vertical 800 N, oblique 10 degrees 800 N, and vertical 800 N + x N torque (x = 10, 50, and 100). The results of cyclic loading tests showed that the fracture resistance of the crown was positively associated with thickness. Specimen breakage differed significantly according to the different thicknesses of the prostheses (p < 0.01). Lowest von Mises stress values were determined for prostheses with a minimal thickness of 1.0 mm in different loading directions and with different forces. Zirconia specimens of 1.0 mm thickness had the lowest stress values and high fracture resistance and under 800 N of loading.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Fracture Strength of Monolithic All-Ceramic Crowns on Titanium Implant Abutments
    Weyhrauch, Michael
    Igiel, Christopher
    Scheller, Herbert
    Weibrich, Gernot
    Lehmann, Karl Martin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (02) : 304 - 309
  • [42] Comparison of Fracture Resistance Between Two Monolithic and One Veneered Zirconia Materials on Molar Crowns After Thermomechanical Fatigue
    Kayali, Faisal
    Kahramanoglu, Erkut
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2020, 10 (03): : 320 - 326
  • [43] Monolithic zirconia dental crowns. Internal fit, margin quality, fracture mode and load at fracture
    Schriwer, Christian
    Skjold, Anneli
    Gjerdet, Nils Roar
    Oilo, Marit
    DENTAL MATERIALS, 2017, 33 (09) : 1012 - 1020
  • [44] Digital Workflow for Implant Rehabilitation with Double Full-Arch Monolithic Zirconia Prostheses
    Papaspyridakos, Panos
    Chochlidakis, Konstantinos
    Kang, Kiho
    Chen, Yo-wei
    Alghfeli, Abdulla
    Kudara, Yukio
    Weber, Hans-Peter
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (06): : 460 - 465
  • [45] Effect of supporting dies' mechanical properties on fracture behavior of monolithic zirconia molar crowns
    Jian, Yutao
    Zhang, Tianyi
    Wang, Xiaodong
    Kyaw, Laina
    Pow, Edmond Ho Nang
    Zhao, Ke
    DENTAL MATERIALS JOURNAL, 2022, 41 (02) : 249 - 255
  • [46] Fracture Strength of Monolithic Zirconia Crowns with Modified Vertical Preparation: A Comparative In Vitro Study
    Abdulazeez, Marwah Ismael
    Majeed, Manhal A.
    EUROPEAN JOURNAL OF DENTISTRY, 2022, 16 (01) : 209 - 214
  • [47] Fracture Load and Phase Transformation of Monolithic Zirconia Crowns Submitted to Different Aging Protocols
    Bergamo, E. T. P.
    da Silva, W. J.
    Cesar, P. F.
    Del Bel Cury, A. A.
    OPERATIVE DENTISTRY, 2016, 41 (05) : E118 - E130
  • [48] Influence of the yttrium content on the fracture strength of monolithic zirconia crowns after artificial aging
    Elsayed, Adham
    Meyer, Gunnar
    Wille, Sebastian
    Kern, Matthias
    QUINTESSENCE INTERNATIONAL, 2019, 50 (05): : 344 - 348
  • [49] Dynamic wear characteristics and fracture strength of high-translucent monolithic zirconia crowns
    Zhou, Ming
    Meng, Meng
    Chai, Zhiguo
    Zhang, Yaming
    Li, Ding
    Niu, Lina
    Jia, Yanmin
    Zhang, Shaofeng
    Wang, Fu
    CERAMICS INTERNATIONAL, 2022, 48 (08) : 11298 - 11303
  • [50] Clinical Fit of Monolithic Zirconia Single Crowns
    Rau, Stefanie Anke
    Raedel, Michael
    Mikeli, Aikaterini
    Raedel, Martina
    Walter, Michael H.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (05) : 443 - 445