Fracture Resistance of Monolithic Zirconia Crowns in Implant Prostheses in Patients with Bruxism

被引:9
|
作者
Lan, Ting-Hsun [1 ,2 ]
Pan, Chin-Yun [3 ]
Liu, Pao-Hsin [4 ]
Chou, Mitch M. C. [5 ]
机构
[1] Kaohsiung Med Univ Hosp, Dept Dent, Div Prosthodont, Kaohsiung 80708, Taiwan
[2] Kaohsiung Med Univ, Coll Dent Med, Sch Dent, Kaohsiung 80708, Taiwan
[3] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Dent, Div Orthodont, Kaohsiung 80708, Taiwan
[4] I Shou Univ, Dept Biomed Engn, Kaohsiung 82442, Taiwan
[5] Natl Sun Yat Sen Univ, Dept Mat & Optoelect Sci, Kaohsiung 80424, Taiwan
关键词
monolithic zirconia crown; thickness; dental implant prosthesis; cyclic loading; finite element analysis; TOOTH WEAR; FAILURE LOAD; MANAGEMENT; COMPLICATIONS; OCCLUSION; CERAMICS; THERAPY; DESIGN; SLEEP;
D O I
10.3390/ma12101623
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The aim of this study is to determine the minimum required thickness of a monolithic zirconia crown in the mandibular posterior area for patients with bruxism. Forty-nine full zirconia crowns, with seven different occlusal thicknesses of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm, were made by using a computer-aided design/computer-aided manufacturing system (CAD/CAM). Seven crowns in each group were subjected to cyclic loading at 800 N and 5 Hz in a servohydraulic testing machine until fracture or completion of 100,000 cycles. Seven finite element models comprising seven different occlusal thicknesses of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm were simulated using three different loads of vertical 800 N, oblique 10 degrees 800 N, and vertical 800 N + x N torque (x = 10, 50, and 100). The results of cyclic loading tests showed that the fracture resistance of the crown was positively associated with thickness. Specimen breakage differed significantly according to the different thicknesses of the prostheses (p < 0.01). Lowest von Mises stress values were determined for prostheses with a minimal thickness of 1.0 mm in different loading directions and with different forces. Zirconia specimens of 1.0 mm thickness had the lowest stress values and high fracture resistance and under 800 N of loading.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Influence of implant abutment angulations on the fracture resistance of overlaying CAM-milled zirconia single crowns
    Ellakwa, A.
    Raj, T.
    Deeb, S.
    Ronaghi, G.
    Martin, F. E.
    Klineberg, I.
    AUSTRALIAN DENTAL JOURNAL, 2011, 56 (02) : 132 - 140
  • [32] In vitro analysis of the fracture resistance of CAD-CAM monolithic zirconia molar crowns with different occlusal thickness
    Sorrentino, Roberto
    Triulzio, Clementina
    Tricarico, Maria Gabriella
    Bonadeo, Giovanni
    Gherlone, Enrico Felice
    Ferrari, Marco
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 61 : 328 - 333
  • [33] Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging
    Atsu, Saadet Saglam
    Aksan, M. Emin
    Bulut, Ali Can
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) : 622 - 630
  • [34] Effect of the CAD/CAM Milling Protocol on the Fracture Behavior of Zirconia Monolithic Crowns
    Oliveira, Andressa Restani
    Ziglioli, Natalia Ulmi
    Marocho, Susana M. Salazar
    Satterthwaite, Julian
    Borba, Marcia
    MATERIALS, 2024, 17 (12)
  • [35] Effect of Marginal Designs on Fracture Strength of High Translucency Monolithic Zirconia Crowns
    Juntavee, Niwut
    Kornrum, Sasiprapa
    INTERNATIONAL JOURNAL OF DENTISTRY, 2020, 2020
  • [36] Fracture Resistance of Monolithic High-Translucency Crowns Versus Porcelain-Veneered Zirconia Crowns After Artificial Aging: An In Vitro Study
    Ezzat, Yousef
    Sharka, Rayan
    Rayyan, Mohammad
    Al-Rafee, Mohammed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (12)
  • [37] The impact of luting agents and stiffness of implant-abutments on marginal adaptation, chipping, and fracture resistance of zirconia crowns
    Schaefer, Lina
    Winkler, Cornelia
    Brandl, Genoveua
    Eckl, Sebastian
    Preis, Verena
    Behr, Michael
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 39 : 279 - 291
  • [38] Influence of attaching mechanical retentive devices onto frameworks on fracture resistance of implant-supported zirconia crowns
    Kobayashi, Tatsuro
    Honda, Junichi
    Kubochi, Kei
    Iwasaki, Taro
    Watanabe, Yusuke
    Komine, Futoshi
    DENTAL MATERIALS JOURNAL, 2024, 43 (03) : 359 - 366
  • [39] Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses
    Lopez-Suarez, Carlos
    Rodriguez, Veronica
    Pelaez, Jesus
    Agustin-Panadero, Ruben
    Suarez, Maria J.
    DENTAL MATERIALS JOURNAL, 2017, 36 (06) : 816 - 821
  • [40] Fracture resistance of CAD-CAM monolithic ceramic and veneered zirconia molar crowns after aging in a mastication simulator
    Gungor, Merve Bankoglu
    Nemli, Secil Karakoca
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03): : 473 - 480