Development and validation of a virtual reality transrectal ultrasound guided prostatic biopsy simulator

被引:22
|
作者
Chalasani, Venu [1 ,2 ,3 ,4 ]
Cool, Derek W. [5 ]
Sherebrin, Shi [5 ]
Fenster, Aaron [5 ]
Chin, Joseph [1 ,2 ,3 ,4 ]
Izawa, Jonathan I. [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Dept Surg, Div Urol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[2] Univ Western Ontario, Dept Surg, Div Surg Oncol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[3] Univ Western Ontario, Dept Oncol, Div Urol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[4] Univ Western Ontario, Dept Oncol, Div Surg Oncol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[5] Univ Western Ontario, Robarts Res Inst, London, ON, Canada
来源
关键词
CANCER; SYSTEM; UROLOGY; SEXTANT; SKILLS;
D O I
10.5489/cuaj.09159
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: We present the design, reliability, face, content and construct validity testing of a virtual reality simulator for transrectal ultrasound (TRUS), which allows doctors-in-training to perform multiple different biopsy schemes. Methods: This biopsy system design uses a regular "end-firing" TRUS probe. Movements of the probe are tracked with a micro-magnetic sensor to dynamically slice through a phantom patient's 3D prostate volume to provide real-time continuous TRUS views. 3D TRUS scans during prostate biopsy clinics were recorded. Intrinsic reliability was assessed by comparing the left side of the prostate to the right side of the prostate for each biopsy. A content and face validity questionnaire was administered to 26 doctors to assess the simulator. Construct validity was assessed by comparing notes from experts and novices with regards to the time taken and the accuracy of each biopsy. Results: Imaging data from 50 patients were integrated into the simulator. The completed VR TRUS simulator uses real patient images, and is able to provide simulation for 50 cases, with a haptic interface that uses a standard TRUS probe and biopsy needle. Intrinsic reliability was successfully demonstrated by comparing results from the left and right sides of the prostate. Face and content validity respondents noted the realism of the simulator, and its appropriateness as a teaching model. The simulator was able to distinguish between experts and novices during construct validity testing. Conclusions: A virtual reality TRUS simulator has successfully been created. It has promising face, content and construct validity results.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [31] Development and Validation of a Virtual Reality Haptic Femoral Nailing Simulator
    Racy, Malek
    Barrow, Alastair
    Tomlinson, James
    Bello, Fernando
    JOURNAL OF SURGICAL EDUCATION, 2021, 78 (03) : 1013 - 1023
  • [32] Apical block versus basolateral prostatic plexus block in transrectal ultrasound guided prostatic biopsy: A prospective randomized study
    Khurana, N.
    Lavania, P.
    Goyal, R.
    Agrawal, S.
    Dubey, D.
    Mandhani, A.
    Srivastava, A.
    Kapoor, R.
    Kumar, A.
    INDIAN JOURNAL OF UROLOGY, 2006, 22 (02) : 118 - 121
  • [33] Value of ultrasound elastography versus transrectal prostatic biopsy in prostatic cancer detection
    Gadalla, Amr Abd El Fattah Hassan
    Abd El Rahman, Sherif Fathy
    Anis, Shady Elia
    Khalil, Mohsen El-Sayed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2015, 46 (03): : 761 - 768
  • [34] Prostatic ductal adenocarcinoma: An aggressive variant that is underdiagnosed and undersampled on transrectal ultrasound (TRUS)-guided needle biopsy
    Gulavita, Previn
    Hakim, Shaheed W.
    Schieda, Nicola
    Breau, Rodney H.
    Morash, Chris
    Keefe, Daniel T.
    Robertson, Susan J.
    Mai, Kien T.
    Belanger, Eric C.
    Flood, Trevor A.
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2015, 9 (9-10): : 302 - 306
  • [35] Validation of a virtual reality simulator for the use of transvaginal ultrasound in gynaecology and early pregnancy
    Al-Memar, M.
    Saso, S.
    Bobdiwala, S.
    Ameye, L.
    Stalder, C.
    Joash, K.
    Timmerman, D.
    Bourne, T.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2016, 123 : 212 - 212
  • [36] SYSTEMATIC TRANSRECTAL ULTRASOUND-GUIDED BIOPSY OF THE PROSTATE
    GARBER, ST
    GOLDENBERG, SL
    COOPERBERG, PL
    WONG, AD
    BILBY, JH
    MATHIESON, JR
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1994, 45 (05): : 387 - 390
  • [37] ENVIRONMENTAL IMPACT OF TRANSRECTAL ULTRASOUND GUIDED PROSTATE BIOPSY
    Leapman, Michael
    Thiel, Cassandra
    Gordon, Ilyssa
    Nolte, Adam
    Perecman, Aaron
    Overcash, Michael
    Sherman, Jodi
    JOURNAL OF UROLOGY, 2022, 207 (05): : E483 - E484
  • [38] The future perspectives in transrectal prostate ultrasound guided biopsy
    Hwang, Sung Il
    Lee, Hak Jong
    PROSTATE INTERNATIONAL, 2014, 2 (04) : 153 - 160
  • [39] Angiogenesis assessment in transrectal ultrasound guided prostate biopsy
    Dordevic, G.
    Bembic, M.
    Bozic, K.
    Oguic, R.
    Mustac, E.
    VIRCHOWS ARCHIV, 2019, 475 : S171 - S171
  • [40] Antibiotic prophylaxis in ultrasound guided transrectal prostate biopsy
    Sieber, PR
    Rommel, FM
    Agusta, VE
    Breslin, JA
    Huffnagle, HW
    Harpster, LE
    JOURNAL OF UROLOGY, 1997, 157 (06): : 2199 - 2200