Development and validation of a virtual reality transrectal ultrasound guided prostatic biopsy simulator

被引:22
|
作者
Chalasani, Venu [1 ,2 ,3 ,4 ]
Cool, Derek W. [5 ]
Sherebrin, Shi [5 ]
Fenster, Aaron [5 ]
Chin, Joseph [1 ,2 ,3 ,4 ]
Izawa, Jonathan I. [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Dept Surg, Div Urol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[2] Univ Western Ontario, Dept Surg, Div Surg Oncol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[3] Univ Western Ontario, Dept Oncol, Div Urol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[4] Univ Western Ontario, Dept Oncol, Div Surg Oncol, Schulich Sch Med & Dent, London, ON N6A 3K7, Canada
[5] Univ Western Ontario, Robarts Res Inst, London, ON, Canada
来源
关键词
CANCER; SYSTEM; UROLOGY; SEXTANT; SKILLS;
D O I
10.5489/cuaj.09159
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: We present the design, reliability, face, content and construct validity testing of a virtual reality simulator for transrectal ultrasound (TRUS), which allows doctors-in-training to perform multiple different biopsy schemes. Methods: This biopsy system design uses a regular "end-firing" TRUS probe. Movements of the probe are tracked with a micro-magnetic sensor to dynamically slice through a phantom patient's 3D prostate volume to provide real-time continuous TRUS views. 3D TRUS scans during prostate biopsy clinics were recorded. Intrinsic reliability was assessed by comparing the left side of the prostate to the right side of the prostate for each biopsy. A content and face validity questionnaire was administered to 26 doctors to assess the simulator. Construct validity was assessed by comparing notes from experts and novices with regards to the time taken and the accuracy of each biopsy. Results: Imaging data from 50 patients were integrated into the simulator. The completed VR TRUS simulator uses real patient images, and is able to provide simulation for 50 cases, with a haptic interface that uses a standard TRUS probe and biopsy needle. Intrinsic reliability was successfully demonstrated by comparing results from the left and right sides of the prostate. Face and content validity respondents noted the realism of the simulator, and its appropriateness as a teaching model. The simulator was able to distinguish between experts and novices during construct validity testing. Conclusions: A virtual reality TRUS simulator has successfully been created. It has promising face, content and construct validity results.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [11] Hemosepermia after transrectal ultrasound-guided prostatic biopsy: A prospective study
    Abdelkhalek, M.
    Abdelshafy, M.
    Elhelaly, H.
    Kamal, M.
    UROLOGY ANNALS, 2013, 5 (01) : 30 - 33
  • [12] Acute bacterial endocarditis secondary to transrectal ultrasound-guided prostatic biopsy
    Irani, J
    Roblot, F
    Giraudon, BB
    Doré, B
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2002, 36 (02): : 156 - 157
  • [13] Anesthesia in Transrectal Ultrasound Guided Biopsy
    Yetim, Memduh
    Kilickaya, Oguz
    JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2015, 6 (06)
  • [14] Development and face validation of ultrasound-guided renal biopsy virtual trainer
    Enquobahrie, Andinet
    Horvath, Sam
    Arikatla, Sreekanth
    Rosenberg, Avi
    Cleary, Kevin
    Sharma, Karun
    HEALTHCARE TECHNOLOGY LETTERS, 2019, 6 (06) : 210 - 213
  • [15] ULTRASOUND GUIDED PROSTATIC BIOPSY
    QUIROZYFERRARI, FA
    STOOPENR, ME
    CALYMAYOR, M
    SAAVEDRAABRIL, J
    REVISTA MEXICANA DE RADIOLOGIA, 1991, 45 (03): : 113 - 117
  • [16] Transrectal ultrasound guided drainage of prostatic cysts
    Terris, MK
    JOURNAL OF UROLOGY, 1997, 158 (01): : 179 - 180
  • [17] Patients' tolerance of transrectal ultrasound-guided prostatic biopsy: an audit of 104 cases
    Crundwell, MC
    Cooke, PW
    Wallace, DMA
    BJU INTERNATIONAL, 1999, 83 (07) : 792 - 795
  • [18] Patients' tolerance of transrectal ultrasound-guided prostatic biopsy: an audit of 104 cases
    Krishna, NS
    Kumar, PM
    Morrison, L
    BJU INTERNATIONAL, 1999, 84 (07) : 890 - 890
  • [19] Peri-prostatic nerve block is safe in transrectal ultrasound guided prostate biopsy
    Tsang, M. F.
    Cheng, K. C.
    Lam, K. M.
    BJU INTERNATIONAL, 2013, 111 : 9 - 9
  • [20] Failure of ciprofloxacin prophylaxis for ultrasound guided transrectal prostatic biopsy in the era of multiresistant Enterobacteriaceae
    Gilad, J
    Borer, A
    Maimon, N
    Riesenberg, K
    Klein, M
    Schlaeffer, F