Repeatability of Open-MOLLI: An open-source inversion recovery myocardial T1 mapping sequence for fast prototyping

被引:1
|
作者
Gaspar, Andreia S. [1 ,2 ,6 ,7 ]
Silva, Nuno A. [3 ]
Ferreira, Antonio M. [4 ,5 ]
Nunes, Rita G. [1 ,2 ]
机构
[1] Univ Lisbon, Inst Sistemas & Robot Lisboa, Lisbon, Portugal
[2] Univ Lisbon, Dept Bioengn, Inst Super Tecn, Lisbon, Portugal
[3] Luz Saude, Hosp Luz Learning Hlth, Lisbon, Portugal
[4] Ctr Hosp Lisboa Ocidental, Hosp Santa Cruz, Serv Cardiol, Lisbon, Portugal
[5] Hosp Luz, Unidade Imagiol Cardiaca Avancada, Lisbon, Portugal
[6] Univ Lisbon, Inst Sistemas & Robot Lisboa, P-1049001 Lisbon, Portugal
[7] Univ Lisbon, Dept Bioengn, Inst Super Tecn, P-1049001 Lisbon, Portugal
关键词
cardiac MRI; open-source; Pulseq; repeatability; T1; mapping; PULSE SEQUENCE; REPRODUCIBILITY; ACCURACY; VALUES;
D O I
10.1002/mrm.30080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop an open-source prototype of myocardial T1 mapping (Open-MOLLI) to improve accessibility to cardiac T1 mapping and evaluate its repeatability. With Open-MOLLI, we aim to enable faster implementation and testing of sequence modifications and to facilitate inter-scanner and cross-vendor reproducibility studies. Methods: Open-MOLLI is an inversion-recovery sequence using a balanced SSFP (bSSFP) readout, with inversion and triggering schemes based on the 5(3)3 MOLLI sequence, developed in Pulseq. Open-MOLLI and MOLLI sequences were acquired in the ISMRM/NIST phantom and 21 healthy volunteers. In 18 of those subjects, Open-MOLLI and MOLLI were repeated in the same session (test-retest). Results: Phantom T1 values were comparable between methods, specifically for the vial with reference T1 value most similar to healthy myocardium T1 (T1(vial3) = 1027 ms): T1(MOLLI) = 1011 +/- 24 ms versus T1(Open-MOLLI) = 1009 +/- 20 ms. In vivo T1 estimates were similar between Open-MOLLI and MOLLI (T1(MOLLI) = 1004 +/- 33 ms vs. T1(Open-MOLLI) = 998 +/- 52 ms), with a mean difference of -17 ms (p = 0.20), despite noisier Open-MOLLI weighted images and maps. Repeatability measures were slightly higher for Open-MOLLI (RCMOLLI = 3.0% vs. RCOpen-MOLLI = 4.4%). Conclusion: The open-source sequence Open-MOLLI can be used for T1 mapping in vivo with similar mean T1 values to the MOLLI method. Open-MOLLI increases the accessibility to cardiac T1 mapping, providing also a base sequence to which further improvements can easily be added and tested.
引用
收藏
页码:741 / 750
页数:10
相关论文
共 50 条
  • [41] Correlation of Pancreatic T1 Values Using Modified Look-Locker Inversion Recovery Sequence (MOLLI) with Pancreatic Exocrine and Endocrine Function
    Ashihara, Norihiro
    Watanabe, Takayuki
    Kako, Satoko
    Kuraishi, Yasuhiro
    Ozawa, Makiko
    Shigefuji, Shohei
    Kanai, Keita
    Usami, Yoko
    Yamada, Akira
    Umemura, Takeji
    Fujinaga, Yasunari
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (06) : 1 - 9
  • [42] MEASUREMENT OF T1 USING THE MULTIPLE INVERSION-RECOVERY SEQUENCE
    YOUNG, IR
    BYDDER, GM
    COLLINS, AG
    HALL, AS
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 788 - 788
  • [43] T1 mapping using a MOLLI sequence in patients with HFpEF: intrastudy reproducibility and comparison with normal controls
    Vassiliou, V.
    Patel, H.
    Lota, A.
    Malley, T.
    Halliday, B.
    Selvendran, S.
    Aggarwal, N.
    Sri, A.
    Collins, S.
    Nyktari, E.
    Di Mario, C.
    Pennell, D. J.
    Auger, D.
    Raphael, C. E.
    Prasad, S. K.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1113 - 1114
  • [44] Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging
    Jeong Hee Yoon
    Jeong Min Lee
    Munyoung Paek
    Joon Koo Han
    Byung Ihn Choi
    European Radiology, 2016, 26 : 1775 - 1782
  • [45] Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging
    Yoon, Jeong Hee
    Lee, Jeong Min
    Paek, Munyoung
    Han, Joon Koo
    Choi, Byung Ihn
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1775 - 1782
  • [46] T1 mapping of myocardium using inversion recovery cine at 3.0T
    Yanjie Zhu
    Yinzhu Gao
    Yiu-Cho Chung
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [47] Validation and feasibility of liver T1 mapping using free breathing MOLLI sequence in children and young adults
    Yeon Jin Cho
    Woo Sun Kim
    Young Hun Choi
    Seul Bi Lee
    SeungHyun Lee
    Jung-Eun Cheon
    MunYoung Paek
    SeungTae Woo
    Scientific Reports, 10
  • [48] Using Variable Flip Angle (VFA) and Modified Look-Locker Inversion Recovery (MOLLI) T1 mapping in clinical OE-MRI
    Bluemke, Emma
    Bertrand, Ambre
    Chu, Kwun-Ye
    Syed, Nigar
    Murchison, Andrew G.
    Cooke, Rosie
    Greenhalgh, Tessa
    Burns, Brian
    Craig, Martin
    Taylor, Nia
    Shah, Ketan
    Gleeson, Fergus
    Bulte, Daniel
    MAGNETIC RESONANCE IMAGING, 2022, 89 : 92 - 99
  • [49] T1 inversion recovery pulse sequence: could it replace T1 spin echo sequence in neuroimaging by improving tissue contrast?
    Shawky, Mohamed
    Habib, Rehab
    Elsawaf, Ahmed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2019, 50 (01):
  • [50] T1 inversion recovery pulse sequence: could it replace T1 spin echo sequence in neuroimaging by improving tissue contrast?
    Mohamed Shawky
    Rehab Habib
    Ahmed Elsawaf
    Egyptian Journal of Radiology and Nuclear Medicine, 50