Online verification of breath-hold reproducibility using kV-triggered imaging for liver stereotactic body radiation therapy

被引:3
|
作者
Guo, Bingqi [1 ,2 ]
Stephans, Kevin [1 ]
Woody, Neil [1 ]
Antolak, Alexander [1 ]
Moazzezi, Mojtaba [1 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Taussig Canc Inst, Dept Radiat Oncol, Cleveland, OH USA
[2] Cleveland Clin Fdn, Taussig Canc Inst, Dept Radiat Oncol, 9500 Euclid Ave,CA-50, Cleveland, OH 44195 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 09期
关键词
breath-hold reproducibility; liver SBRT; triggered imaging; BEAM COMPUTED-TOMOGRAPHY; CONTROL ABC; GUIDANCE; RADIOTHERAPY; DIAPHRAGM; FEASIBILITY; PRECISION;
D O I
10.1002/acm2.14045
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To introduce a new technique for online breath-hold verification for liver stereotactic body radiation therapy (SBRT) based on kilovoltage-triggered imaging and liver dome positions. Material and Methods: Twenty-five liver SBRT patients treated with deep inspiration breath-hold were included in this IRB-approved study. To verify the breath-hold reproducibility during treatment, a KV-triggered image was acquired at the beginning of each breath-hold. The liver dome position was visually compared with the expected upper/lower liver boundaries created by expanding/contracting the liver contour 5 mm in the superior-inferior direction. If the liver dome was within the boundaries, delivery continued; otherwise, beam was held manually, and the patient was instructed to take another breath-hold until the liver dome fell within boundaries. The liver dome was delineated on each triggered image. The mean distance between the delineated liver dome to the projected planning liver contour was defined as liver dome position error e(dome). The mean and maximum e(dome) of each patient were compared between no breath-hold verification (all triggered images) and with online breath-hold verification (triggered images without beam-hold). Results: Seven hundred thirteen breath-hold triggered images from 92 fractions were analyzed. For each patient, an average of 1.5 breath-holds (range 0-7 for all patients) resulted in beam-hold, accounting for 5% (0-18%) of all breath-holds; online breath-hold verification reduced the mean e(dome) from 3.1 mm (1.3-6.1 mm) to 2.7 mm (1.2-5.2 mm) and the maximum e(dome) from 8.6 mm (3.0-18.0 mm) to 6.7 mm (3.0-9.0 mm). The percentage of breath-holds with e(dome) >5 mm was reduced from 15% (0-42%) without breath-hold verification to 11% (0-35%) with online breath-hold verification. online breath-hold verification eliminated breath-holds with e(dome) >10 mm, which happened in 3% (0-17%) of all breath-holds. Conclusion: It is clinically feasible to monitor the reproducibility of each breath-hold during liver SBRT treatment using triggered images and liver dome. Online breath-hold verification improves the treatment accuracy for liver SBRT.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Dosimetric benefits of dynamic conformal arc therapy-combined with active breath-hold in lung stereotactic body radiotherapy
    Lee, Soyoung
    Lee, Danny
    Verma, Vivek
    Waters, Danielle
    Oh, Seungjong
    Colonias, Athanasios
    Wegner, Rodney
    Pavord, Daniel
    Coopey, Bryan
    Fuhrer, Russell
    Sohn, Jason W.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 54 - 60
  • [42] Deep-inspiration breath-hold kilovoltage cone-beam CT for setup of stereotactic body radiation therapy for lung tumors: Initial experience
    Duggan, Dennis M.
    Ding, George X.
    Coffey, Charles W., II
    Kirby, Wyndee
    Hallahan, Dennis E.
    Malcolm, Arnold
    Lu, Bo
    LUNG CANCER, 2007, 56 (01) : 77 - 88
  • [43] A gated deep inspiration breath-hold radiation therapy technique using a linear position transducer
    Denissova, Svetlana I.
    Yewondwossen, Mammo H.
    Andrew, John W.
    Hale, Michael E.
    Murphy, Carl H.
    Purcell, Scott R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (01): : 61 - 70
  • [44] Breath-Hold Volumetric Modulated Arc Stereotactic Body Radiation Therapy for Early-Stage Lung Cancer Guided by Real-Time Fluoroscopy
    Takanaka, T.
    Kumano, T.
    Shibata, S.
    Ohashi, S.
    Nakagawa, M.
    Isomura, N.
    Noto, K.
    Ueda, S.
    Kurata, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S605 - S606
  • [45] Geometric Reproducibility of Fiducial Markers and Efficacy of a Patient-Specific Margin Design Using Deep Inspiration Breath Hold for Stereotactic Body Radiation Therapy for Pancreatic Cancer
    Han-Oh, Sarah
    Hill, Colin
    Wang, Ken Kang-Hsin
    Ding, Kai
    Wright, Jean L.
    Alcorn, Sara
    Meyer, Jeffrey
    Herman, Joseph
    Narang, Amol
    ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (02)
  • [46] Clinical implementation and evaluation of liver SBRT in breath-hold using nasal high flow therapy
    Hazelaar, C.
    Canters, R.
    Lubken, I.
    Kremer, K.
    Vaassen, F.
    Buijsen, J.
    Berbee, M.
    van Elmpt, W.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1117 - S1118
  • [47] Liver Diffusion-weighted MR Imaging: Reproducibility Comparison of ADC Measurements Obtained with Multiple Breath-hold, Free-breathing, Respiratory-triggered, and Navigator-triggered Techniques
    Chen, Xin
    Qin, Lei
    Pan, Dan
    Huang, Yanqi
    Yan, Lifen
    Wang, Guangyi
    Liu, Yubao
    Liang, Changhong
    Liu, Zaiyi
    RADIOLOGY, 2014, 271 (01) : 113 - 125
  • [48] Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac
    Nguyen, Daniel
    Reinoso, Rebeca
    Farah, Jad
    Yossi, Sena
    Lorchel, Fabrice
    Passerat, Victor
    Louet, Estelle
    Pouchard, Isabelle
    Khodri, Mustapha
    Barbet, Nicolas
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26
  • [49] Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
    Miura, Hideharu
    Ozawa, Shuichi
    Doi, Yoshiko
    Nakao, Minoru
    Kubo, Katsumaro
    Kenjo, Masahiko
    Nagata, Yasushi
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (04) : 575 - 585
  • [50] Assessment of setup uncertainty in hypofractionated liver radiation therapy with a breath-hold technique using automatic image registration–based image guidance
    Gye Won Choi
    Yelin Suh
    Prajnan Das
    Joseph Herman
    Emma Holliday
    Eugene Koay
    Albert C. Koong
    Sunil Krishnan
    Bruce D. Minsky
    Grace L. Smith
    Cullen M. Taniguchi
    Sam Beddar
    Radiation Oncology, 14