Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac

被引:10
|
作者
Nguyen, Daniel [1 ]
Reinoso, Rebeca [1 ]
Farah, Jad [2 ]
Yossi, Sena [1 ]
Lorchel, Fabrice [1 ]
Passerat, Victor [1 ]
Louet, Estelle [1 ]
Pouchard, Isabelle [1 ]
Khodri, Mustapha [1 ]
Barbet, Nicolas [1 ]
机构
[1] ORLAMs Grp, Dept Radiat Oncol, Lyon, France
[2] Vis RT Ltd, Dove House,Arcadia Ave, London N3 2JU, England
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2023年 / 26卷
关键词
Deep-inspiration breath-hold; Lung stereotactic body radiotherapy; Ring-mounted SGRT system; Intra-fraction control; TUMOR MOTION; SYSTEM; EXPERIENCE; ACCURACY; TRACKING; CANCER;
D O I
10.1016/j.phro.2023.100448
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Tumor motion and delivery efficiency are two main challenges of lung stereotactic body radiotherapy (SBRT). The present work implemented the deep inspiration breath hold technique (DIBH) with surface guided radiation therapy (SGRT) on closed-bore linacs and investigated the correlation between SGRT data and internal target position. Materials and methods: Thirteen lung SBRT patients treated in DIBH using a closed-bore gantry linac and a ring-mounted SGRT system were retrospectively analysed. Visual coaching was used to achieve DIBH with a +/- 1 mm threshold window in the anterior-posterior direction. Three kV-CBCTs were added to the treatment workflow and examined offline to verify intra-fraction tumor position. Surface-based DIBH was analysed using SGRT treatment reports and an in-house python script. Data from 73 treatment sessions and 175 kV-CBCTs were studied. Correlations between target and surface positions were studied with Linear Mixed Models. Results: Median intra-fraction tumor motion was 0.8 mm (range: 0.7-1.3 mm) in the anterior-posterior direction, 1.2 mm (range: 1-1.7 mm) in the superior-inferior direction, and 1 mm (range: 0.7-1.1 mm) in the left-right direction, with rotations of <1 degrees (range: 0.6 degrees-1.1 degrees) degree in all three directions. Planned target volumes and healthy lung volumes receiving 12.5 Gy and 13.5 Gy were reduced on average by 67% and 54%, respectively. Conclusions: Lung SBRT in DIBH with the ring-mounted SGRT system proved reproducible. The surface monitoring provided by SGRT was found to be a reliable surrogate for internal target motion. Moreover, the implementation of DIBH technique helped reduce target volumes and lung doses.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Application and dosimetric comparison of surface-guided deep inspiration breath-hold for lung stereotactic body radiotherapy
    Wang, Jiaxin
    Dong, Tingting
    Meng, Xiangyin
    Li, Wenbo
    Li, Nan
    Wang, Yijun
    Yang, Bo
    Qiu, Jie
    MEDICAL DOSIMETRY, 2024, 49 (04) : 372 - 379
  • [2] Investigating Stability and Reproducibility of Deep Inspiration Breath Hold for Liver Stereotactic Body Radiotherapy
    Parsons, D.
    Iqbal, Z.
    Sanford, N. N.
    Reynolds, R.
    Stojadinovic, S.
    Aguilera, T. A.
    Chiu, T.
    Lu, W.
    Folkert, M. R.
    Gu, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E632 - E632
  • [3] Early Experiences of Deep Inspiration Breath Hold Technique in Stereotactic Body Radiotherapy for Localized Lung Tumor
    Mani, K. R.
    Sumon, M. A.
    Chaudhuri, S.
    Nabi, R.
    Sengupta, A. K.
    Ahmed, S.
    Uddin, A. Kamal
    Bhuiyan, M. A.
    Haque, K. A.
    Lingaiah, R.
    Ahmed, S. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E330 - E330
  • [4] Evaluating intra-fractional tumor motion in lung stereotactic radiotherapy with deep inspiration breath-hold
    Fu, Weihua
    Zhang, Yongqian
    Mehta, Kiran
    Chen, Alex
    Musunuru, Hima Bindu
    Pucci, Pietro
    Kubis, Jason
    Huq, M. Saiful
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [5] Characteristics of Tumor Motions with Deep Inspiration Breath Hold for Lung Stereotactic Body Radiotherapy Patients
    Zhao, G.
    Jayarathna, S. Y.
    Peeler, C. R.
    Pollard-Larkin, J. M.
    Sadagopan, R.
    Nitsch, P. L.
    Ohrt, J. D.
    Gao, S.
    Balter, P.
    Wang, X.
    MEDICAL PHYSICS, 2024, 51 (10) : 7861 - 7862
  • [6] Feasibility of Optical Surface-Guidance for Position Verification and Monitoring of Stereotactic Body Radiotherapy in Deep-Inspiration Breath-Hold
    Naumann, Patrick
    Batista, Vania
    Farnia, Benjamin
    Fischer, Jann
    Liermann, Jakob
    Tonndorf-Martini, Eric
    Rhein, Bernhard
    Debus, Juergen
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [7] Targeting accuracy of a deep inspiration breath-hold technique for locoregional breast radiotherapy
    Wells, D.
    Wai, E.
    Bendorffe, B.
    Bardutz, M.
    Rose, A.
    Norn, D.
    Peterson, R.
    McDonald, R.
    Cunningham, H.
    Sayers, D.
    Runkel, J.
    Cooper, S.
    Popescu, C.
    Beckham, W.
    Olivotto, I.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S15 - S15
  • [8] Tailored stereotactic radiotherapy technique using deep inspiration breath-hold to reduce stomach dose for cardiac radioablation
    Cha, Myung-Jin
    Cuculich, Phillip S.
    Robinson, Clifford G.
    Chang, Ji Hyun
    RADIATION ONCOLOGY JOURNAL, 2021, 39 (03): : 167 - 173
  • [9] Heart position reproducibility in deep inspiration breath hold radiotherapy for lung cancer
    Josipovic, M.
    Aznar, M. C.
    Thomsen, J. B.
    Scherman, J.
    Damkjaer, S. M. S.
    Nygard, L.
    Specht, L.
    Pohl, M.
    Persson, G. F.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1062 - S1063
  • [10] Expanded Visual Guidance of Breath-Hold for CBCT-Guided Online Adaptive Radiotherapy (ART) in a Closed-Bore Configuration
    Kim, T.
    Shin, J.
    Kim, J.
    Barberi, E.
    Henke, L.
    Mutic, S.
    Cai, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E618 - E618