Electrode Montage Induced Changes in Air-Conducted Ocular Vestibular-Evoked Myogenic Potential

被引:2
|
作者
Raveendran, Rajesh Kumar [1 ]
Singh, Niraj Kumar [1 ]
机构
[1] All India Inst Speech & Hearing, Dept Audiol, Mysore 570006, Karnataka, India
来源
EAR AND HEARING | 2024年 / 45卷 / 01期
关键词
Electrode placement; Electrode montage; Inferior oblique muscle; Reliability; Utricular function test; MOTOR UNIT-ACTIVITY; MUSCLE; STIMULATION; FREQUENCY; POSITION; SOUND; RESPONSES; OVEMPS;
D O I
10.1097/AUD.0000000000001419
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: Stimulus and recording parameters are pivotal for shaping the ocular vestibular-evoked myogenic potential (oVEMP). In the last decade, several attempts were made to identify the optimum electrode placement site to improve the oVEMP responses. A vast majority of these found larger response amplitudes for alternate electrode montages like belly-tendon (BT), chin-referenced (CR), and/or sternum-referenced montages than the clinically used infra-orbital montage. However, no study has yet compared all alternate electrode montages in a simultaneous recording paradigm to eliminate other confounding factors. Also, no study has compared all of them for their test-retest reliability, waveform morphology, and signal-to-noise ratio. Therefore, the decision on which among these electrode montages is best suited for oVEMP acquisition remains opaque. The present study aimed to investigate the effects of various electrode montages on oVEMP's response parameters and to determine the test-retest reliability of each of these in clinically healthy individuals using a simultaneous recording paradigm. Design: This study had a within-subject experimental design. Fifty-five young healthy adults (age range: 20-30 years) underwent contralateral oVEMP recording using infra-orbital, BT, chin-referenced, and sternum-referenced electrode montages simultaneously using a four-channel evoked potential system. Results: BT montage had a significantly shorter latency, larger amplitude, higher signal-to-noise ratio, and better morphology than other alternate montages (p < 0.008). Further, all electrode montages of the current study showed fair/moderate to excellent test-retest reliability. Conclusions: By virtue of producing significantly better response parameters than the other electrode montages, BT montage seems better suited to the recording of oVEMP than the known electrode montages thus far.
引用
收藏
页码:227 / 238
页数:12
相关论文
共 50 条
  • [31] Vestibular-evoked extraocular potentials by sound: Another clinical test for vestibular air-conducted function
    Chihara, Yasuhiro
    Iwasaki, Shinichi
    Ushio, Munetaka
    Murofushi, Toshihisa
    CLINICAL NEUROPHYSIOLOGY, 2007, 118 (12) : 2745 - 2751
  • [32] Evidence Missed: Ocular Vestibular-Evoked Myogenic Potential and Cervical Vestibular-Evoked Myogenic Potential Differentiate Utricular from Saccular Function
    Curthoys, Ian S.
    Manzari, Leonardo
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2011, 144 (05) : 751 - 752
  • [33] Controversy on the sensory origin of oVEMP to air-conducted sound: A reply to "Ocular vestibular evoked myogenic potential (oVEMP) responses in acute vestibular neuritis"
    Oh, Sun-Young
    Kim, Ji Soo
    CLINICAL NEUROPHYSIOLOGY, 2012, 123 (05) : 1055 - 1056
  • [34] Preliminary study on vestibular-evoked myogenic potential induced by bone-conducted stimuli
    Miyamoto, Atsushi
    Seo, Toru
    Node, Michiko
    Hashimoto, Misako
    Sakagami, Masafumi
    OTOLOGY & NEUROTOLOGY, 2006, 27 (08) : 1110 - 1114
  • [35] Air- and Bone-Conducted Cervical and Ocular Vestibular-Evoked Myogenic Potentials in Patients with Superior Vestibular Neuritis
    Oh, Sun-Young
    Kim, Ji Soo
    Shin, Byoung-Soo
    Yang, Tae-Ho
    Jeong, Seul-Ki
    NEUROLOGY, 2013, 80
  • [36] Air- and Bone-Conducted Cervical and Ocular Vestibular-Evoked Myogenic Potentials in Patients with Superior Vestibular Neuritis
    Oh, Sun-Young
    Kim, Ji Soo
    Shin, Byoung-Soo
    Yang, Tae-Ho
    Jeong, Seul-Ki
    NEUROLOGY, 2013, 80
  • [37] Ocular vestibular-evoked myogenic potentials using air-conducted sound: test parameters and normative data in healthy children; effect of body position on threshold
    Ioannis Kastanioudakis
    Panagiotis Saravakos
    Theodoros Leontis
    Dimitrios G. Balatsouras
    Nausica Ziavra
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 2385 - 2394
  • [38] Ocular vestibular-evoked myogenic potentials using air-conducted sound: test parameters and normative data in healthy children; effect of body position on threshold
    Kastanioudakis, Ioannis
    Saravakos, Panagiotis
    Leontis, Theodoros
    Balatsouras, Dimitrios G.
    Ziavra, Nausica
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (09) : 2385 - 2394
  • [39] Electrode montage and gaze effects on ocular vestibular evoked myogenic potentials (oVEMPs)
    Govender, Sendhil
    Cheng, Petrina Y.
    Dennis, Danielle L.
    Colebatch, James G.
    CLINICAL NEUROPHYSIOLOGY, 2016, 127 (08) : 2846 - 2854
  • [40] Perioperative Bone-Conducted Ocular Vestibular-Evoked Myogenic Potentials in Otosclerosis Patients
    Winters, Stephanie M.
    Klis, Sjaak F. L.
    Kool, Angelica C. M.
    Kraaijenga, Sophie A. C.
    Tange, Rinze A.
    Grolman, Wilko
    OTOLOGY & NEUROTOLOGY, 2013, 34 (06) : 1109 - 1114