Electrode Montage Induced Changes in Air-Conducted Ocular Vestibular-Evoked Myogenic Potential

被引:2
|
作者
Raveendran, Rajesh Kumar [1 ]
Singh, Niraj Kumar [1 ]
机构
[1] All India Inst Speech & Hearing, Dept Audiol, Mysore 570006, Karnataka, India
来源
EAR AND HEARING | 2024年 / 45卷 / 01期
关键词
Electrode placement; Electrode montage; Inferior oblique muscle; Reliability; Utricular function test; MOTOR UNIT-ACTIVITY; MUSCLE; STIMULATION; FREQUENCY; POSITION; SOUND; RESPONSES; OVEMPS;
D O I
10.1097/AUD.0000000000001419
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: Stimulus and recording parameters are pivotal for shaping the ocular vestibular-evoked myogenic potential (oVEMP). In the last decade, several attempts were made to identify the optimum electrode placement site to improve the oVEMP responses. A vast majority of these found larger response amplitudes for alternate electrode montages like belly-tendon (BT), chin-referenced (CR), and/or sternum-referenced montages than the clinically used infra-orbital montage. However, no study has yet compared all alternate electrode montages in a simultaneous recording paradigm to eliminate other confounding factors. Also, no study has compared all of them for their test-retest reliability, waveform morphology, and signal-to-noise ratio. Therefore, the decision on which among these electrode montages is best suited for oVEMP acquisition remains opaque. The present study aimed to investigate the effects of various electrode montages on oVEMP's response parameters and to determine the test-retest reliability of each of these in clinically healthy individuals using a simultaneous recording paradigm. Design: This study had a within-subject experimental design. Fifty-five young healthy adults (age range: 20-30 years) underwent contralateral oVEMP recording using infra-orbital, BT, chin-referenced, and sternum-referenced electrode montages simultaneously using a four-channel evoked potential system. Results: BT montage had a significantly shorter latency, larger amplitude, higher signal-to-noise ratio, and better morphology than other alternate montages (p < 0.008). Further, all electrode montages of the current study showed fair/moderate to excellent test-retest reliability. Conclusions: By virtue of producing significantly better response parameters than the other electrode montages, BT montage seems better suited to the recording of oVEMP than the known electrode montages thus far.
引用
收藏
页码:227 / 238
页数:12
相关论文
共 50 条
  • [21] Differing response properties of cervical and ocular vestibular evoked myogenic potentials evoked by air-conducted stimulation
    Dennis, Danielle L.
    Govender, Sendhil
    Chen, Peggy
    Todd, Neil P. McAngus
    Colebatch, James G.
    CLINICAL NEUROPHYSIOLOGY, 2014, 125 (06) : 1238 - 1247
  • [22] Ocular vestibular-evoked myogenic potentials in children using air conducted sound stimulation
    Hsu, Ying-Shuo
    Wang, Shou-Jen
    Young, Yi-Ho
    CLINICAL NEUROPHYSIOLOGY, 2009, 120 (07) : 1381 - 1385
  • [23] Ocular Vestibular Evoked Myogenic Potentials in Response to Air-Conducted Sound in Meniere's Disease
    Winters, Stephanie M.
    Campschroer, Thijs
    Grolman, Wilko
    Klis, Sjaak F. L.
    OTOLOGY & NEUROTOLOGY, 2011, 32 (08) : 1273 - 1280
  • [24] Effects of acoustic stimulation intensity on air-conducted vestibular evoked myogenic potential in children
    Xiao, Qianwen
    Zhang, Qin
    Wu, Qiong
    Shen, Jiali
    Wang, Lu
    Chen, Yanfei
    Lv, Jingrong
    Yang, Jun
    Jin, Yulian
    Zhang, Qing
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [25] Ocular vestibular evoked myogenic potentials to head tap and cervical vestibular evoked myogenic potentials to air-conducted sounds in isolated internuclear ophthalmoplegia
    Kim, Hyo-Jung
    Lee, Jong Hee
    Kim, Ji-Soo
    CLINICAL NEUROPHYSIOLOGY, 2014, 125 (05) : 1042 - 1047
  • [26] Effect of Stimulus Frequency on Air-Conducted Vestibular Evoked Myogenic Potentials
    Fu, Wei
    Han, Junliang
    He, Feng
    Wang, Yuanyuan
    Wei, Dong
    Shi, Ying
    Bai, Ya
    Wang, Xiaoming
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2021, 17 (05): : 422 - 425
  • [27] Ocular vestibular evoked myogenic potential elicited from binaural air-conducted stimulations: clinical feasibility in patients with peripheral vestibular dysfunction
    Iwasaki, Shinichi
    Egami, Naoya
    Inoue, Aki
    Kinoshita, Makoto
    Fujimoto, Chisato
    Murofushi, Toshihisa
    Yamasoba, Tatsuya
    ACTA OTO-LARYNGOLOGICA, 2013, 133 (07) : 708 - 713
  • [28] Frequency-tuning characteristics of cervical and ocular vestibular evoked myogenic potentials induced by air-conducted tone bursts
    Park, Hong Ju
    Lee, In-Sik
    Shin, Jung Eun
    Lee, Yeo Jin
    Park, Mun Su
    CLINICAL NEUROPHYSIOLOGY, 2010, 121 (01) : 85 - 89
  • [29] Ocular and cervical vestibular evoked myogenic potentials elicited by air-conducted, low-frequency sound
    Luecke, Vivien Nancy
    Buchwieser, Laura
    Eulenburg, Peter zu
    Marquardt, Torsten
    Drexl, Markus
    JOURNAL OF VESTIBULAR RESEARCH-EQUILIBRIUM & ORIENTATION, 2020, 30 (04): : 235 - 247
  • [30] Influence of the Electrode Montage to Detect Ocular Vestibular Evoked Myogenic Potentials
    Mat, Quentin
    Deggouj, Naima
    Duterme, Jean-Pierre
    Tainmont, Sophie
    Lelubre, Christophe
    Manto, Mario
    OTOLOGY & NEUROTOLOGY, 2023, 44 (06) : E412 - E418