List-mode quantitative joint reconstruction of activity and attenuation maps in Time-of-Flight PET

被引:1
|
作者
Hemmati, Hamidreza [1 ,2 ]
Kamali-Asl, Alireza [3 ]
Ghafarian, Pardis [4 ,5 ]
Rahmim, Arman [6 ,7 ]
Zaidi, Habib [8 ,9 ,10 ,11 ]
Ay, Mohammad Reza [1 ,12 ]
机构
[1] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA USA
[3] Shahid Beheshti Univ, Dept Med Radiat Engn, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, NRITLD, Chron Resp Dis Res Ctr, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, PET CT & Cyclotron Ctr, Tehran, Iran
[6] Univ British Columbia, Dept Radiol & Phys, Vancouver, BC, Canada
[7] BC Canc, Res Ctr, Dept Integrat Oncol, Vancouver, BC, Canada
[8] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[9] Univ Geneva, Neuroctr, Geneva, Switzerland
[10] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[11] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[12] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
基金
瑞士国家科学基金会; 美国国家科学基金会;
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Medical-image reconstruction methods and algorithms; computer-aided diagnosis; Multi-modality systems; IMAGE-RECONSTRUCTION; SIMULATION;
D O I
10.1088/1748-0221/18/09/P09041
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Quantitative PET imaging requires accurate determination of patient-specific attenuation maps, which remains challenging on hybrid PET/MRI systems owing to the lack of a direct relationship between MR image intensity and attenuation coefficients. The aim of the present study is to develop a list-mode based algorithm for accurate and robust attenuation correction of PET data using time-of-flight (TOF) emission information. We analyze and address the challenges of list-mode emission-based maximum-likelihood joint estimation of activity and attenuation (LM-MLAA) in state-of-the-art PET imaging. The proposed method exploits a rapid on-the-fly system matrix calculation algorithm based on elliptic integrals while updating the attenuation map from accumulating list-mode coincidences to achieve accelerated image reconstruction. The scattering compensation is incorporated inside it using an iterative approach in such that the current estimation of attenuation map used on a course grid sampling scattering points to make an estimate of scattering. The performance of the proposed LM-MLAA approach was evaluated on Monte Carlo simulations of a phantom at different time resolutions. The contrast and noise for hot and cold regions on reconstructed images at different time resolutions were analysed. The estimated attenuation map exhibits resilience against noise, effectively eliminates high-frequency cross-talk even in the absence of prior information on attenuation coefficients, and enables discrimination among different anatomical regions in the reconstructed image. The error in the mean estimated attenuation coefficients after 50 iterations was similar to 2% in water and similar to -14% in Teflon regions for TOF resolutions corresponding to those of most current commercial PET systems (similar to 500 ps). The proposed LM-MLAA framework can be used for joint reconstruction of activity and attenuation maps from list-mode emission data as standalone or a complementary approach to existing in multimodality imaging such as PET/MRI, where direct measurement attenuation maps is not possible.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Projector with Realistic Detector Scatter Modelling for PET List-Mode Reconstruction
    Autret, Awen
    Bert, Julien
    Strauss, Olivier
    Visvikis, Dimitris
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3333 - 3336
  • [42] Compensation of patient motion in PET using a rotator and list-mode reconstruction
    Chen, Yu
    Glick, J.
    King, Michael A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2692 - 2696
  • [43] Spatially Variant Resolution Modelling for Iterative List-Mode PET Reconstruction
    Bickell, Matthew G.
    Zhou, Lin
    Nuyts, Johan
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [44] Comparison of Maximum-Likelihood List-Mode Reconstruction Algorithms in PET
    Brinks, Ralph
    Schretter, Colas
    Meyer, Carsten
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2801 - 2803
  • [45] Spatially Variant Resolution Modelling for Iterative List-Mode PET Reconstruction
    Bickell, Matthew G.
    Zhou, Lin
    Nuyts, Johan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (07) : 1707 - 1718
  • [46] Comparison of external motion tracking systems for PET list-mode reconstruction
    Olesen, Oline V.
    Paulsen, Rasmus R.
    Keller, Sune H.
    Hojgaard, Liselotte
    Roed, Bjame
    Larsen, Rasmus
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3414 - 3416
  • [47] List-Mode PET Image Reconstruction Using Deep Image Prior
    Ote, Kibo
    Hashimoto, Fumio
    Onishi, Yuya
    Isobe, Takashi
    Ouchi, Yasuomi
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (06) : 1822 - 1834
  • [48] Determination of the system matrix used in list-mode EM reconstruction of PET
    Chen, Yu
    Glick, Stephen J.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3855 - 3858
  • [49] Hybrid PET-MR list-mode kernelized expectation maximization reconstruction for quantitative PET images of the carotid arteries
    Deidda, Daniel
    Karakatsanis, Nicolas
    Robson, Philip M.
    Efthimiou, Nikos
    Fayad, Zahi A.
    Aykroyd, Robert G.
    Tsoumpas, Charalampos
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [50] Implementation of scatter corrected List-Mode OP-EM reconstruction algorithm and a dual (Histogram/List-Mode) reconstruction scheme for dynamic PET imaging
    Cheng, Ju-Chieh
    Rahmim, Arman
    Blinder, Stephan
    Camborde, Marie-Laure
    Sossi, Vesna
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2291 - 2295